315 matches found
CVE-2019-5408
Command View Advanced Edition CVAE products contain a vulnerability that could expose configuration information of hosts and storage systems that are managed by Device Manager server. This problem is due to a vulnerability in Device Manager GUI. The following products are affected. DevMgr version...
Bug in Anesthesia Respirators Allows Cyber-Tampering
A vulnerability in GE Healthcare’s Aestiva and Aespire anesthesia devices would allow an unauthenticated cybercriminal on the same network as the device to modify gas composition parameters within the devices’ respirator function, thus changing sensor readings for gas density. According to GE...
CloudBees Jenkins Stores Passwords in Plaintext
CloudBees Jenkins Hudson Labs is the United States CloudBees company's set of Java-based development of continuous integration tools. The product is mainly used to monitor the continuous software version release/testing project and some timed tasks . PRQA Plugin is one of the use of PRQA static...
imcat information disclosure vulnerability (CNVD-2019-00970)
imcat is a PHP-based open source website building system . A security vulnerability exists in imcat version 4.4. Remote attackers can use root/tools/adbug/check.php URI to obtain sensitive configuration information...
CVE-2018-18441
D-Link DCS series Wi-Fi cameras expose sensitive information regarding the device configuration. The affected devices include many of DCS series, such as: DCS-936L, DCS-942L, DCS-8000LH, DCS-942LB1, DCS-5222L, DCS-825L, DCS-2630L, DCS-820L, DCS-855L, DCS-2121, DCS-5222LB1, DCS-5020L, and many mor...
CVE-2018-15407
A vulnerability in the installation process of Cisco HyperFlex Software could allow an authenticated, local attacker to read sensitive information. The vulnerability is due to insufficient cleanup of installation files. An attacker could exploit this vulnerability by accessing the residual...
Authentication flaw
Containous Traefik 1.6.x before 1.6.6, when --api is used, exposes the configuration and secret if authentication is missing and the API's port is publicly reachable...
CVE-2018-15598
Containous Traefik 1.6.x before 1.6.6, when --api is used, exposes the configuration and secret if authentication is missing and the API's port is publicly reachable...
CVE-2018-15598
Containous Traefik 1.6.x before 1.6.6, when --api is used, exposes the configuration and secret if authentication is missing and the API's port is publicly reachable...
CVE-2018-15598
Traefik 1.6.x before 1.6.6 exposes configuration and secrets when the API is enabled (--api) and the API port is publicly reachable if authentication is missing. Root cause is missing authentication on the API surface, leading to information disclosure. Impact is disclosure of sensitive configura...
CVE-2017-1286: Exposure of Sensitive Information to an Unauthorized Actor
Sensitive information about the configuration of the IBM UrbanCode Deploy 6.1 through 6.9.6.0 server and database can be obtained by a user who has been given elevated permissions in the UI, even after those elevated permissions have been revoked. IBM X-Force ID: 125147...
CVE-2017-12167
It was found in EAP 7 before 7.0.9 that properties based files of the management and the application realm configuration that contain user to role mapping are world readable allowing access to users and roles information to all the users logged in to the system...
CVE-2018-8755
NuCom WR644GACV devices before STA006 allow an attacker to download the configuration file without credentials. By downloading this file, an attacker can access the admin password, WPA key, and any config information of the device...
Multiple TIBCO Product Information Disclosure Vulnerabilities (CNVD-2018-10558)
TIBCO JasperReports Server and so on are the products of the United States TIBCO Software Corporation.TIBCO JasperReports Server is a report generation and editing tools for the server version of the TIBCO JasperReports Server Community Edition is the community version of it. A security...
CVE-2017-9969
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information...
CVE-2017-11165
dataTaker DT80 dEX 1.50.012 allows remote attackers to obtain sensitive credential and configuration information via a direct request for the /services/getFile.cmd?userfile=config.xml URI...
DataTaker DT80 dEX 1.50.012 Sensitive Configuration Exposure Vulnerability
DataTaker DT80 dEX version 1.50.012 suffers from an information disclosure vulnerability. + Title: DataTaker DT80 dEX 1.50.012 - Sensitive Configurations Exposure + Credits / Discovery: Nassim Asrir + Author Contact: email protected || https://www.linkedin.com/in/nassim-asrir-b73a57122/ + Author...
Local File Containment Vulnerability in KuaiFanCMS
KuaiFanCMS V5.x is developed with PHP5+MYSQL as the technical base. kf is built with Smarty template engine. A local file include vulnerability exists in the KuaiFanCMS /upload/index.php file. Due to the parameters within the include are not filtered, can lead to .class.php suffix file include, i...
CVE-2016-3727
The API URL computer/master/api/xml in Jenkins before 2.3 and LTS before 1.651.2 allows remote authenticated users with extended read permission for the master node to obtain sensitive information about the global configuration via unspecified vectors...
PT-2016-3179 · Siemens · Siemens Sicam Pas
Name of the Vulnerable Software and Affected Versions: Siemens SICAM PAS versions prior to 8.07 Description: The issue is related to insufficient password protection in databases, which could allow a local attacker with certain database privileges to calculate passwords. Additionally, it may enab...