Lucene search
+L

13032 matches found

NVD
NVD
added 2020/06/30 5:15 p.m.22 views

CVE-2020-15087

In Presto before version 337, authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured. This does not affect installations that have not configured secure internal communication,...

8.8CVSS0.01058EPSS
SaveExploits0References2
OSV
OSV
added 2020/06/30 5:15 p.m.14 views

CVE-2020-15087

In Presto before version 337, authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured. This does not affect installations that have not configured secure internal communication,...

8.8CVSS8.7AI score
SaveExploits0References2
Prion
Prion
added 2020/06/30 5:15 p.m.16 views

Authorization

In Presto before version 337, authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured. This does not affect installations that have not configured secure internal communication,...

6.5CVSS8.6AI score0.01058EPSS
SaveExploits0References2Affected Software1
ATTACKERKB
ATTACKERKB
added 2020/06/30 5:15 p.m.5 views

CVE-2020-15087

In Presto before version 337, authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured. This does not affect installations that have not configured secure internal communication,...

8.8CVSS7.9AI score0.01058EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
added 2020/06/30 4:35 p.m.34 views

CVE-2020-15087 Privilege escalation in Presto

In Presto before version 337, authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured. This does not affect installations that have not configured secure internal communication,...

7.4CVSS8.7AI score0.01058EPSS
SaveExploits0References2
Github Security Blog
Github Security Blog
added 2020/06/30 4:33 p.m.39 views

Privilege escalation in Presto

Affected This affects Presto server installations. This does NOT affect clients such as the CLI or JDBC driver. Impact Authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured...

8.8CVSS3.3AI score0.01058EPSS
SaveExploits0References6Affected Software1
OSV
OSV
added 2020/06/30 4:33 p.m.50 views

GHSA-F6PC-CRHH-CP96 Privilege escalation in Presto

Affected This affects Presto server installations. This does NOT affect clients such as the CLI or JDBC driver. Impact Authenticated users can bypass authorization checks by directly accessing internal APIs. This impacts Presto server installations with secure internal communication configured...

7.4CVSS8.8AI score0.01058EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2020/06/30 12:00 a.m.11 views

PT-2020-14175 · Presto · Presto

Name of the Vulnerable Software and Affected Versions: Presto versions prior to 337 Description: Authenticated users can bypass authorization checks by directly accessing internal APIs. This issue impacts Presto server installations with secure internal communication configured. It does not affec...

8.8CVSS8.6AI score0.01058EPSS
SaveExploits0References7
NVD
NVD
added 2020/06/29 2:15 p.m.38 views

CVE-2020-12040

Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...

9.8CVSS0.00948EPSS
SaveExploits1References1
OSV
OSV
added 2020/06/29 2:15 p.m.12 views

CVE-2019-18246

BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure...

4.3CVSS5.8AI score0.00464EPSS
SaveExploits0References1
OSV
OSV
added 2020/06/29 2:15 p.m.13 views

CVE-2019-18252

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure...

4.3CVSS5.8AI score0.00464EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.35 views

CVE-2019-18252

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure...

4.3CVSS0.00464EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.25 views

CVE-2020-12008

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI...

7.5CVSS0.00948EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/29 2:15 p.m.21 views

Design/Logic Flaw

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure...

3.3CVSS4.9AI score0.00464EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2020/06/29 2:15 p.m.24 views

Code injection

Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...

5CVSS9.3AI score0.00948EPSS
SaveExploits1References1Affected Software1
Prion
Prion
added 2020/06/29 2:15 p.m.20 views

Authentication flaw

BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure...

3.3CVSS4.9AI score0.00464EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2020/06/29 2:15 p.m.25 views

Design/Logic Flaw

BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure...

3.3CVSS4.7AI score0.00351EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2020/06/29 2:15 p.m.23 views

Information disclosure

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI...

5CVSS7.7AI score0.00948EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2020/06/29 1:58 p.m.36 views

CVE-2019-18252

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure...

4.9AI score0.00464EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:58 p.m.36 views

CVE-2019-18248

BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure...

4.7AI score0.00351EPSS
SaveExploits0References1
Rows per page
Query Builder