141 matches found
Siemens SIMATIC RF185C 6GT2002-0JE10 RFID Communication Module Detection
Binary data 765320.prm...
Siemens SIMATIC RF188C 6GT2002-0JE40 RFID Communication Module Detection
Binary data 765322.prm...
Siemens SIMATIC RF186C 6GT2002-0JE20 RFID Communication Module Detection
Binary data 765321.prm...
Information disclosure
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module...
CVE-2019-6850
The CVE-2019-6850 issue affects Schneider Electric Modicon M580 and BMENOC 0311/0321. The vulnerability is an information disclosure (CWE-200) that occurs when reading specific registers via the controller/communication module REST API, allowing exposure of sensitive data. Root cause is informati...
Siemens SIMATIC RF186CI 6GT2002-0JE50 RFID Communication Module Detection
Binary data 765268.prm...
Siemens SIMATIC RF188CI 6GT2002-0JE40 RFID Communication Module Detection
Binary data 765269.prm...
The vulnerability of Siemens CP’s communication module’s microprogramming software, related to the lack of protective measures for website structures, allows attackers to carry out cross-site scripting attacks.
The vulnerability of Siemens CP’s communication module’s microprogramming software is related to the lack of measures taken to protect the structure of the web page. Exploiting this vulnerability allows a remote attacker to perform a cross-site scripting attack...
Unauthorized Access Vulnerability in Communication Module CLM920_NC5 of Shanghai Haige Information Technology Co.
Ltd. is engaged in the research, development, production and operation of 3G/3.75G/4G/NB communication module, which is a communication module company with a patch production factory. An unauthorized access vulnerability exists in communication module CLM920NC5 of Shanghai Haige Information...
Siemens SIRIUS Motor Starter M200D Communication Module PROFINET
Binary data 764685.prm...
Rockwell Automation/Allen-Bradley 1794 FLEX I/O Communication Module Detection
Binary data 193.prm...
Siemens Climatix BACnet/IP Communication Module < 10.34 XSS
Binary data 720066.prm...
Hitachi Communication Module Detection
Binary data 757809.prm...
Rockwell Automation 1756-RIO ControlLogix Remote I/O Communication Module
Binary data 752986.prm...
Hitachi Communication Module Detection
Binary data 757808.prm...
Covert Backdoor Transmission Method: GhostTunnel
GhostTunnel is a covert backdoor transmission method that can be used in an isolated environment. It can attack the target through the HID device only to release the payload agent, then the HID device can be removed after the payload is released. GhostTunnel use 802.11 Probe Request Frames and...
The vulnerability of the microprogramming software of the TIM 1531 IRC communication module, related to authentication errors, allows a perpetrator to gain access to the device with administrator privileges.
The vulnerability of the microprogramming software for the TIM 1531 IRC communication module is related to the improper implementation of the authentication algorithm. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain access to the device with administrator...
Siemens TIM 1531 IRC Security Bypass Vulnerability
The Siemens TIM 1531 IRC is a communication module from Siemens that handles data transfer using the Siemens remote control protocol SINAUT ST7. A security vulnerability exists in the Siemens TIM 1531 IRC prior to version 1.1. A remote attacker could use this vulnerability to perform administrati...
Siemens CP 243 Communication Module HTTP Detection
Binary data 700225.prm...
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Memory Read Vulnerability
The Medfusion 4000 Wireless Syringe Infusion Pump is a syringe infusion pump deployed in healthcare and public health for delivering small doses of medication in acute care settings. A memory read vulnerability exists in the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, where a...