4464 matches found
Cross site request forgery (csrf)
A vulnerability in the web-based interface of Cisco Hosted Collaboration Mediation Fulfillment HCM-F could allow an unauthenticated, remote attacker to conduct a cross-site request forgery CSRF attack on an affected system. The vulnerability is due to insufficient CSRF protections by the affected...
CVE-2019-15289
CVE-2019-15289 affects Cisco TelePresence Collaboration Endpoint (CE) and Cisco RoomOS Software. The issue is denial-of-service via the video service caused by insufficient input validation, exploitable by unauthenticated remote actors sending crafted traffic to the endpoint’s video service, whic...
CVE-2020-3124 Cisco Hosted Collaboration Mediation Fulfillment Cross-Site Request Forgery Vulnerability
A vulnerability in the web-based interface of Cisco Hosted Collaboration Mediation Fulfillment HCM-F could allow an unauthenticated, remote attacker to conduct a cross-site request forgery CSRF attack on an affected system. The vulnerability is due to insufficient CSRF protections by the affected...
CVE-2020-16247
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...
CVE-2020-16200
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...
CVE-2020-16247
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...
CVE-2020-14525
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...
CVE-2020-14506
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...
CVE-2020-16198
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct...
CVE-2020-14506
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...
CVE-2020-14525
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...
Design/Logic Flaw
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...
Design/Logic Flaw
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...
Input validation
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...
CVE-2020-16247 Philips Clinical Collaboration Platform Configuration
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...
CVE-2020-16247
The CVE-2020-16247 vulnerability affects Philips Clinical Collaboration Platform (rebranded as Philips Clinical Collaboration Platform; affected versions 12.2.1 and prior). The root cause is Improper Access Control: the product exposes a resource to the wrong control sphere, allowing unintended a...
CVE-2020-16200 Philips Clinical Collaboration Platform Algorithm Downgrade
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...
CVE-2020-16200
Philips Clinical Collaboration Platform, versions 12.2.1 and earlier, is affected by CVE-2020-16200 (Algorithm Downgrade). The vulnerability stems from improper control of limited resources, enabling an attacker to influence resource consumption and exhaust availability (impact: HIGH). The root c...
CVE-2020-16198
Philips Clinical Collaboration Platform (HMI data management) versions 12.2.1 and earlier are affected by CVE-2020-16198. The root cause is insufficient verification of claimed identities, i.e., aProtection Mechanism Failure that does not adequately prove identity. Mitigations include Philips pat...
CVE-2020-14525 Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...