Lucene search
+L

4464 matches found

Prion
Prion
added 2020/09/23 1:15 a.m.15 views

Cross site request forgery (csrf)

A vulnerability in the web-based interface of Cisco Hosted Collaboration Mediation Fulfillment HCM-F could allow an unauthenticated, remote attacker to conduct a cross-site request forgery CSRF attack on an affected system. The vulnerability is due to insufficient CSRF protections by the affected...

4.3CVSS6.8AI score0.005EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/09/23 12:30 a.m.86 views

CVE-2019-15289

CVE-2019-15289 affects Cisco TelePresence Collaboration Endpoint (CE) and Cisco RoomOS Software. The issue is denial-of-service via the video service caused by insufficient input validation, exploitable by unauthenticated remote actors sending crafted traffic to the endpoint’s video service, whic...

7.8CVSS7.6AI score0.01374EPSS
SaveExploits0References1Affected Software2
Vulnrichment
Vulnrichment
added 2020/09/23 12:25 a.m.9 views

CVE-2020-3124 Cisco Hosted Collaboration Mediation Fulfillment Cross-Site Request Forgery Vulnerability

A vulnerability in the web-based interface of Cisco Hosted Collaboration Mediation Fulfillment HCM-F could allow an unauthenticated, remote attacker to conduct a cross-site request forgery CSRF attack on an affected system. The vulnerability is due to insufficient CSRF protections by the affected...

6.5CVSS7.4AI score0.005EPSS
SaveExploits0References1
OSV
OSV
added 2020/09/18 6:15 p.m.5 views

CVE-2020-16247

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...

7.1CVSS7.1AI score0.00361EPSS
SaveExploits0References2
OSV
OSV
added 2020/09/18 6:15 p.m.8 views

CVE-2020-16200

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...

6.5CVSS5.8AI score0.00621EPSS
SaveExploits0References2
NVD
NVD
added 2020/09/18 6:15 p.m.27 views

CVE-2020-16247

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...

7.1CVSS0.00361EPSS
SaveExploits0References2
NVD
NVD
added 2020/09/18 6:15 p.m.26 views

CVE-2020-14525

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...

3.5CVSS0.00472EPSS
SaveExploits0References2
OSV
OSV
added 2020/09/18 6:15 p.m.10 views

CVE-2020-14506

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...

4.3CVSS5.8AI score0.00288EPSS
SaveExploits0References2
NVD
NVD
added 2020/09/18 6:15 p.m.23 views

CVE-2020-16198

When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct...

6.3CVSS0.00564EPSS
SaveExploits0References2
NVD
NVD
added 2020/09/18 6:15 p.m.27 views

CVE-2020-14506

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...

4.3CVSS0.00288EPSS
SaveExploits0References2
OSV
OSV
added 2020/09/18 6:15 p.m.9 views

CVE-2020-14525

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...

3.5CVSS5.8AI score0.00472EPSS
SaveExploits0References2
Prion
Prion
added 2020/09/18 6:15 p.m.19 views

Design/Logic Flaw

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...

3.3CVSS6.5AI score0.00621EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2020/09/18 6:15 p.m.16 views

Design/Logic Flaw

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...

2.7CVSS4.3AI score0.00472EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2020/09/18 6:15 p.m.20 views

Input validation

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...

4.3CVSS4.7AI score0.00288EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/09/18 5:55 p.m.33 views

CVE-2020-16247 Philips Clinical Collaboration Platform Configuration

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...

6.8CVSS6.8AI score0.00361EPSS
SaveExploits0References2
CVE
CVE
added 2020/09/18 5:55 p.m.57 views

CVE-2020-16247

The CVE-2020-16247 vulnerability affects Philips Clinical Collaboration Platform (rebranded as Philips Clinical Collaboration Platform; affected versions 12.2.1 and prior). The root cause is Improper Access Control: the product exposes a resource to the wrong control sphere, allowing unintended a...

7.1CVSS6.7AI score0.00361EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/09/18 5:53 p.m.25 views

CVE-2020-16200 Philips Clinical Collaboration Platform Algorithm Downgrade

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...

6.5CVSS6.3AI score0.00621EPSS
SaveExploits0References2
CVE
CVE
added 2020/09/18 5:53 p.m.59 views

CVE-2020-16200

Philips Clinical Collaboration Platform, versions 12.2.1 and earlier, is affected by CVE-2020-16200 (Algorithm Downgrade). The vulnerability stems from improper control of limited resources, enabling an attacker to influence resource consumption and exhaust availability (impact: HIGH). The root c...

6.5CVSS6.6AI score0.00621EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2020/09/18 5:50 p.m.56 views

CVE-2020-16198

Philips Clinical Collaboration Platform (HMI data management) versions 12.2.1 and earlier are affected by CVE-2020-16198. The root cause is insufficient verification of claimed identities, i.e., aProtection Mechanism Failure that does not adequately prove identity. Mitigations include Philips pat...

6.3CVSS5.8AI score0.00564EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/09/18 5:48 p.m.27 views

CVE-2020-14525 Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...

3.5CVSS3.5AI score0.00472EPSS
SaveExploits0References2
Rows per page
Query Builder