Lucene search
+L

9006 matches found

Cvelist
Cvelist
added 2018/09/10 5:00 p.m.27 views

CVE-2018-16705

FURUNO FELCOM 250 and 500 devices allow unauthenticated access to the xml/permission.xml file containing all of the system's usernames and passwords. This includes the Admin and Service user accounts and their unsalted MD5 hashes, as well as the SMS server password in cleartext...

9.7AI score0.01573EPSS
SaveExploits1References2
ICS
ICS
added 2018/09/10 12:00 p.m.39 views

Schneider Electric StruxureWare Building Expert Plaintext Credentials Vulnerability

OVERVIEW Independent researcher Artyom Kurbatov has identified a cleartext transmission vulnerability in Schneider Electric’s StruxureWare Building Expert product. Schneider Electric has produced a new firmware version that mitigates this vulnerability. Artyom Kurbatov has tested the new firmware...

5CVSS6.7AI score0.01199EPSS
SaveExploits0References18
OSV
OSV
added 2018/09/07 10:29 p.m.9 views

CVE-2017-17691

Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack...

8.1CVSS5.8AI score0.01029EPSS
SaveExploits1References1
Prion
Prion
added 2018/09/07 10:29 p.m.20 views

Design/Logic Flaw

Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack...

4.3CVSS7.7AI score0.01029EPSS
SaveExploits1References1Affected Software1
NVD
NVD
added 2018/09/07 10:29 p.m.20 views

CVE-2017-17691

Homeputer CL Studio fur HomeMatic 4.0 Rel 160808 and earlier uses cleartext to exchange the username and password between server and client instances, which allows remote attackers to obtain sensitive information via a man in the middle attack...

8.1CVSS7.8AI score0.01029EPSS
SaveExploits1References1
CVE
CVE
added 2018/09/07 10:00 p.m.55 views

CVE-2017-17691

CVE-2017-17691 affects Homeputer CL Studio for HomeMatic (4.0 Rel 160808 and earlier). The vulnerability arises from cleartext exchange of username and password between server and client, enabling a remote attacker to capture credentials via a man-in-the-middle attack. The provided connected docu...

8.1CVSS7.7AI score0.01029EPSS
SaveExploits1References1Affected Software1
Prion
Prion
added 2018/09/05 9:29 p.m.23 views

Default credentials

An issue was discovered in BTITeam XBTIT 2.5.4. When a user logs in, their password hash is rehashed using a predictable salt and stored in the "pass" cookie, which is not flagged as HTTPOnly. Due to the weak and predictable salt that is in place, an attacker who successfully steals this cookie c...

5CVSS9.3AI score0.00751EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2018/09/05 9:00 p.m.56 views

CVE-2018-15680

CVE-2018-15680 affects BTITeam XBTIT 2.5.4 where passwords in the xbtit_users table are stored as unsalted MD5 hashes. The root cause is weak password hashing, enabling context-dependent attackers to brute-force and recover cleartext passwords. Public details in the provided documents confirm the...

9.8CVSS9AI score0.00792EPSS
SaveExploits1References1Affected Software1
CNVD
CNVD
added 2018/09/05 12:00 a.m.12 views

Philips e-Alert Information Disclosure Vulnerability (CNVD-2019-28281)

Philips e-Alert is an electronic alert solution for MRI systems from Philips in the Netherlands, which is used to monitor and alert on MRI system performance. An information disclosure vulnerability exists in Philips e-Alert R2.1 and prior versions, which originates when a program passes sensitiv...

8.8CVSS8.5AI score0.0057EPSS
SaveExploits0References1
ICS
ICS
added 2018/08/30 12:00 a.m.187 views

Philips e-Alert Unit

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit/exploitable from within the same local subnet Vendor: Philips Equipment: Philips e-Alert Unit non-medical device Vulnerabilities: Improper Input Validation, Cross-site Scripting, Information Exposure,...

9.8CVSS9AI score0.03834EPSS
SaveExploits0References5
CNVD
CNVD
added 2018/08/14 12:00 a.m.12 views

Multiple Medtronic Products Information Disclosure Vulnerability (CNVD-2018-18137)

Medtronic MMT-508 MiniMed insulin pump and others are different models of insulin pumps from Medtronic, USA. An information disclosure vulnerability exists in a number of Medtronic products, which arises from communication between the pump and wireless accessories being passed in clear text. An...

5.3CVSS5.2AI score0.00474EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2018/08/13 10:00 p.m.32 views

CVE-2018-10634 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Cleartext Transmission of Sensitive Information

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers...

4.8CVSS5.3AI score0.00474EPSS
SaveExploits0References3
OSV
OSV
added 2018/08/13 9:48 p.m.14 views

CVE-2018-15124

Weak hashing algorithm in Zipato Zipabox Smart Home Controller BOARD REV - 1 with System Version -118 allows unauthenticated attacker extract clear text passwords and get root access on the device...

9.8CVSS5.8AI score0.01072EPSS
SaveExploits0References1
NVD
NVD
added 2018/08/13 9:47 p.m.26 views

CVE-2018-10634

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers...

5.3CVSS5.2AI score0.00474EPSS
SaveExploits0References3
Prion
Prion
added 2018/08/13 9:47 p.m.24 views

Information disclosure

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker cou...

2.9CVSS5.2AI score0.00474EPSS
SaveExploits0References2
ICS
ICS
added 2018/08/07 12:00 a.m.150 views

Siemens OpenSSL Vulnerability in Industrial Products (Update E)

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION : Exploitable remotely Vendor : Siemens Equipment : Industrial Products Vulnerability : Cleartext Transmission of Sensitive Information 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-18-226-02 Siemens...

5.9CVSS6.7AI score0.78675EPSS
SaveExploits1References11
ICS
ICS
added 2018/08/07 12:00 a.m.55 views

Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...

5.9AI score
SaveExploits0References5
Cvelist
Cvelist
added 2018/08/03 5:00 p.m.35 views

CVE-2018-13416

In Universal Media Server UMS 7.1.0, the XML parsing engine for SSDP/UPnP functionality is vulnerable to an XML External Entity Processing XXE attack. Remote, unauthenticated attackers can use this vulnerability to: 1 Access arbitrary files from the filesystem with the same permission as the user...

9.8AI score0.20185EPSS
SaveExploits5References2
OSV
OSV
added 2018/07/31 2:29 p.m.10 views

CVE-2018-11338

Intuit Lacerte 2017 for Windows in a client/server environment transfers the entire customer list in cleartext over SMB, which allows attackers to 1 obtain sensitive information by sniffing the network or 2 conduct man-in-the-middle MITM attacks via unspecified vectors. The customer list contains...

7.5CVSS5.8AI score0.01207EPSS
SaveExploits1References2
Prion
Prion
added 2018/07/31 2:29 p.m.26 views

Design/Logic Flaw

Intuit Lacerte 2017 for Windows in a client/server environment transfers the entire customer list in cleartext over SMB, which allows attackers to 1 obtain sensitive information by sniffing the network or 2 conduct man-in-the-middle MITM attacks via unspecified vectors. The customer list contains...

5CVSS7.3AI score0.01207EPSS
SaveExploits1References2Affected Software1
Rows per page
Query Builder