8960 matches found
CVE-2020-10549
rConfig 3.9.4 and previous versions has unauthenticated snippets.inc.php SQL injection. Because, by default, nodes’ passwords are stored in cleartext, this vulnerability leads to lateral movement, granting an attacker access to monitored network devices. Recent assessments: theguly at June 04, 20...
CVE-2020-10548
rConfig 3.9.4 and previous versions has unauthenticated devices.inc.php SQL injection. Because, by default, nodes’ passwords are stored in cleartext, this vulnerability leads to lateral movement, granting an attacker access to monitored network devices. Recent assessments: theguly at June 04, 202...
CVE-2020-10546
rConfig 3.9.4 and previous versions has unauthenticated compliancepolicies.inc.php SQL injection. Because, by default, nodes’ passwords are stored in cleartext, this vulnerability leads to lateral movement, granting an attacker access to monitored network devices. Recent assessments: theguly at...
CVE-2020-13783
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Storage of Sensitive Information...
CVE-2020-13783
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Storage of Sensitive Information...
CVE-2020-13787
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information...
CVE-2020-13787
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information...
Information disclosure
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information...
Information disclosure
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Storage of Sensitive Information...
CVE-2020-13783
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Storage of Sensitive Information...
CVE-2020-13783
CVE-2020-13783 affects the D-Link DIR-865L Ax firmware 1.20B01 Beta. The root cause is cleartext storage of sensitive information in the device, enabling information disclosure if storage is accessed. Multiple sources (CNVD, Red Hat) classify this as an information disclosure vulnerability. No re...
CVE-2020-13787
D-Link DIR-865L Ax 1.20B01 Beta devices have Cleartext Transmission of Sensitive Information...
CVE-2020-13787
CVE-2020-13787 affects D-Link DIR-865L Ax devices with firmware 1.20B01 Beta, where sensitive information can be disclosed due to cleartext transmission over the network. The connected sources describe an information-disclosure vulnerability and a potential for attackers to sniff traffic to obtai...
Rockwellautomation Micrologix Cleartext Storage of Sensitive Information
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol SMTP account data is saved in RSLogix 500, a local attacker with access to a...
Palo Alto Networks PAN-OS 7.1.x < 7.1.26 / 8.0.x < 8.1.13 / 8.1.x < 8.1.13 / 9.0.x < 9.0.6 / 9.1.x < 9.1.1 Vulnerability
The version of Palo Alto Networks PAN-OS running on the remote host is 7.1.x prior to 7.1.26 or 8.0.x prior to 8.1.13 or 8.1.x prior to 8.1.13 or 9.0.x prior to 9.0.6 or 9.1.x prior to 9.1.1. It is, therefore, affected by a vulnerability. - A cleartext transmission of sensitive information...
CVE-2020-9045 C•CURE 9000 and victor Video Management System - Cleartext storage of user credentials upon installation or upgrade of software.
During installation or upgrade to Software House C•CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation...
Johnson Controls Software House C-CURE 9000 and American Dynamics victor VMS
1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Sensormatic Electronics, LLC, a subsidiary of Johnson Controls Equipment: Software House C•CURE 9000 and American Dynamics victor Video Management System Vulnerability: Cleartext Storage of...
CVE-2020-12859
Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext payload data. This allows re-identification of devices, especially less common phone models or those in low-density situations...
CVE-2020-12859
Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext payload data. This allows re-identification of devices, especially less common phone models or those in low-density situations...
Design/Logic Flaw
Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext payload data. This allows re-identification of devices, especially less common phone models or those in low-density situations...