8898 matches found
CVE-2022-38458
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information...
Design/Logic Flaw
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information...
CVE-2022-38458
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information...
CVE-2022-38458
CVE-2022-38458 affects Netgear Orbi Router RBR750 (4.6.8.5). Talos documented a cleartext transmission vulnerability in Remote Management that enables MITM-based disclosure of sensitive data. The TALOS-2022-1598 advisory confirms the vulnerability details and notes that vulnerability appears in t...
PT-2023-13606 · NetGear · Netgear Orbi Router Rbr750
Name of the Vulnerable Software and Affected Versions: Netgear Orbi Router RBR750 version 4.6.8.5 Description: A cleartext transmission issue exists in the Remote Management functionality. This can be exploited by a specially-crafted man-in-the-middle attack, potentially leading to the disclosure...
Netgear Orbi Router RBR750 Remote Management cleartext transmission vulnerability
Talos Vulnerability Report TALOS-2022-1598 Netgear Orbi Router RBR750 Remote Management cleartext transmission vulnerability March 21, 2023 CVE Number CVE-2022-38458 SUMMARY A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5....
Tridium Niagara AX Insufficiently Protected Credentials (CVE-2012-3025)
The default configuration of Tridium Niagara AX Framework through 3.6 uses a cleartext base64 format for transmission of credentials in cookies, which allows remote attackers to obtain sensitive information by sniffing the network. This plugin only works with Tenable.ot. Please visit...
Amazon Linux 2023 : curl, curl-minimal, libcurl (ALAS2023-2023-114)
It is, therefore, affected by multiple vulnerabilities as referenced in the ALAS2023-2023-114 advisory. A flaw was found in the Curl package, where the HSTS mechanism would be ignored by subsequent transfers when done on the same command line because the state would not be properly carried. This...
Exploit for Insufficiently Protected Credentials in Kyocera Net_Viewer
kyocera-cve-2022-1026 An unauthenticated data extraction vulne...
CVE-2023-25596 Authenticated Sensitive Information Disclosure in ClearPass Policy Manager
A vulnerability exists in ClearPass Policy Manager that allows for an attacker with administrative privileges to access sensitive information in a cleartext format. A successful exploit allows an attacker to retrieve information which could be used to potentially gain further access to network...
CVE-2023-25596
CVE-2023-25596 affects Aruba ClearPass Policy Manager. Multiple sources describe an authenticated attacker with administrative privileges able to access sensitive information in cleartext via the web management interface, with potential to facilitate further access to network services. The Connec...
PT-2023-20187 · Aruba Networks · Clearpass Policy Manager
Name of the Vulnerable Software and Affected Versions: ClearPass Policy Manager affected versions not specified Description: A vulnerability exists in ClearPass Policy Manager that allows an attacker with administrative privileges to access sensitive information in a cleartext format. This could...
Security Bulletin: Vulnerability in moment-timezone affects IBM VM Recovery Manager HA GUI
Summary There is vulnerability in moment-timezone opensource package which affects IBM VM Recovery Manager HA and DR GUI. Vulnerability Details IBM X-Force ID: 238619 DESCRIPTION: Moment Moment-Timezone is vulnerable to a man-in-the-middle attack, caused by cleartext transmission of tz data durin...
EulerOS 2.0 SP5 : squid (EulerOS-SA-2023-1515)
According to the versions of the squid package installed, the EulerOS installation on the remote host is affected by the following vulnerabilities : - A buffer over-read was discovered in libntlmauth in Squid 2.5 through 5.6. Due to incorrect integer- overflow protection, the SSPI and SMB...
Amazon Linux 2 : curl (ALAS-2023-1986)
The version of curl installed on the remote host is prior to 7.88.0-1. It is, therefore, affected by multiple vulnerabilities as referenced in the ALAS2-2023-1986 advisory. A flaw was found in the Curl package, where the HSTS mechanism would be ignored by subsequent transfers when done on the sam...
FreeBSD : curl -- multiple vulnerabilities (be233fc6-bae7-11ed-a4fb-080027f5fec9)
The version of FreeBSD installed on the remote host is prior to tested version. It is, therefore, affected by multiple vulnerabilities as referenced in the be233fc6-bae7-11ed-a4fb-080027f5fec9 advisory. - A cleartext transmission of sensitive information vulnerability exists in curl v7.88.0 that...
CVE-2023-0053
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could...
CVE-2023-0053
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could...
CVE-2023-0053 SAUTER Controls Nova 200–220 Series Cleartext Transmission of Sensitive Information
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could...
CVE-2023-0053
SAUTER Controls Nova 200–220 Series (firmware 3.3-006 and earlier) and BACnetstac 4.2.1 and earlier expose credentials in cleartext because device management relies on FTP/Telnet. CVE-2023-0053 documents cleartext transmission of sensitive information and potential credential exposure, with an im...