Lucene search
+L

821 matches found

Prion
Prion
added 2022/02/09 11:15 p.m.19 views

Cross site request forgery (csrf)

A CWE-352: Cross-Site Request Forgery CSRF exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert...

6.8CVSS8.8AI score0.00677EPSS
Exploits0References1Affected Software7
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.6 views

Schneider Electric EcoStruxure EV Charging Expert 跨站请求伪造漏洞

Schneider Electric EcoStruxure EV Charging Expert is an electric vehicle charging infrastructure load management, access management, and supervision solution from Schneider Electric France. Schneider Electric EcoStruxure EV Charging Expert suffers from a cross-site request forgery vulnerability...

8.8CVSS7.8AI score0.00677EPSS
Exploits0References2
Cvelist
Cvelist
added 2022/02/09 12:0 a.m.38 views

CVE-2022-22808

A CWE-352: Cross-Site Request Forgery CSRF exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert...

9.1AI score0.00677EPSS
Exploits0References1
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.7 views

EcoStruxure EV Charging Expert 安全漏洞

EcoStruxure EV Charging Expert is an electric vehicle charging infrastructure load management, access management and supervision solution from Schneider-electric, France. A security vulnerability exists in EcoStruxure EV Charging Expert, which stems from CWE-1021 An improper restriction in the...

7.4CVSS7.3AI score0.00938EPSS
Exploits0References3
Cvelist
Cvelist
added 2022/02/09 12:0 a.m.32 views

CVE-2022-22807

A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert former...

7.6AI score0.00938EPSS
Exploits0References1
CVE
CVE
added 2022/02/09 12:0 a.m.91 views

CVE-2022-22808

Schneider Electric EcoStruxure EV Charging Expert (formerly EVlink Load Management System) is affected by a CSRF vulnerability (CVE-2022-22808) in versions prior to V4.0.0.13. The issue enables a remote attacker to gain unauthorized access by bypassing same-origin policy protections through cross...

8.8CVSS8.8AI score0.00677EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2022/02/09 12:0 a.m.126 views

CVE-2022-22807

The CVE-2022-22807 entry applies to EcoStruxure EV Charging Expert (pre-SP8 V4.0.0.13). Root cause: CWE-1021 Improper Restriction of Rendered UI Layers or Frames, enabling an attacker to influence the product by deceiving users to interact with an iframe-rendered web interface. Impact: potential ...

7.4CVSS7.3AI score0.00938EPSS
Exploits0References1Affected Software1
Positive Technologies
Positive Technologies
added 2022/02/09 12:0 a.m.5 views

PT-2022-15690 · Schneider Electric · Ecostruxure Ev Charging Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure EV Charging Expert formerly known as EVlink Load Management System versions prior to V4.0.0.13 Description: A Cross-Site Request Forgery CSRF issue exists, allowing a remote attacker to gain unauthorized access to the product by...

8.8CVSS9AI score0.00677EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2022/02/08 12:0 a.m.7 views

PT-2022-6694 · Schneider Electric · Ecostruxure Ev Charging Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure EV Charging Expert versions prior to V4.0.0.13 Description: A vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within...

8.5CVSS7.2AI score0.00938EPSS
Exploits0References7
NVD
NVD
added 2022/01/28 8:15 p.m.33 views

CVE-2021-22821

A CWE-918 Server-Side Request Forgery SSRF vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 All...

8.6CVSS0.00823EPSS
Exploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.37 views

CVE-2021-22820

A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4...

9.8CVSS0.01084EPSS
Exploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.3 views

CVE-2021-22821

A CWE-918 Server-Side Request Forgery SSRF vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 All...

8.6CVSS5.8AI score0.00823EPSS
Exploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.3 views

CVE-2021-22818

A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 All versions prior to R8...

7.5CVSS7.1AI score0.01005EPSS
Exploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.2 views

CVE-2021-22822

A CWE-79 Improper Neutralization of Input During Web Page Generation �Cross-site Scripting� vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargi...

6.1CVSS5.8AI score
Exploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.23 views

CVE-2021-22822

A CWE-79 Improper Neutralization of Input During Web Page Generation �Cross-site Scripting� vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargi...

6.1CVSS0.00562EPSS
Exploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.4 views

CVE-2021-22725

A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...

8.8CVSS5.8AI score0.00468EPSS
Exploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.22 views

CVE-2021-22724

A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...

8.8CVSS0.00468EPSS
Exploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.7 views

CVE-2021-22724

A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...

8.8CVSS5.8AI score0.00468EPSS
Exploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.23 views

CVE-2021-22725

A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...

8.8CVSS0.00468EPSS
Exploits0References1
Prion
Prion
added 2022/01/28 8:15 p.m.15 views

Cross site request forgery (csrf)

A CVE-352 Cross-Site Request Forgery CSRF vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22...

6.8CVSS8.6AI score0.00468EPSS
Exploits0References1Affected Software6
Rows per page
Query Builder