Lucene search
+L

823 matches found

ATTACKERKB
ATTACKERKB
added 2026/03/20 2:43 a.m.4 views

CVE-2026-32937

free5GC is an open source 5G core network. free5GC CHF prior to version 1.2.2 has an out-of-bounds slice access vulnerability in the CHF nchf-convergedcharging service. A valid authenticated request to PUT /nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=... can trigger a server-side panic...

7.1CVSS5.8AI score0.00404EPSS
SaveExploits0References5Affected Software1
OSV
OSV
added 2026/03/20 2:43 a.m.9 views

CVE-2026-32937 free5GC CHF has Out-of-Bounds Slice Access that Leads to DoS

free5GC is an open source 5G core network. free5GC CHF prior to version 1.2.2 has an out-of-bounds slice access vulnerability in the CHF nchf-convergedcharging service. A valid authenticated request to PUT /nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=... can trigger a server-side panic...

7.1CVSS6.3AI score0.00404EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2026/03/20 12:0 a.m.17 views

PT-2026-26699

CVE-2026-31926 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. https://t.co/dYBTlDrxSN...

6.9CVSS5.8AI score0.00292EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2026/03/20 12:0 a.m.10 views

IGL-Technologies eParking.fi 访问控制错误漏洞

IGL-Technologies eParking.fi is an intelligent parking platform provided by IGL-Technologies, offering features for parking management, charging, and parking space monitoring. IGL-Technologies eParking.fi has a security vulnerability related to access control. This vulnerability stems from the la...

9.8CVSS5.7AI score0.00468EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2026/03/20 12:0 a.m.14 views

PT-2026-26695

CVE-2026-28204 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. https://t.co/aldAqfvMsO...

6.9CVSS5.8AI score0.00301EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2026/03/20 12:0 a.m.10 views

PT-2026-26686

Name of the Vulnerable Software and Affected Versions CTEK Chargeport affected versions not specified Description WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated...

9.8CVSS5.8AI score0.00483EPSS
SaveExploits0References12
CNNVD
CNNVD
added 2026/03/20 12:0 a.m.6 views

free5GC 输入验证错误漏洞

free5GC is an open-source project for the 5th generation 5G mobile core network. Versions of free5GC prior to 1.2.2 contained a vulnerability related to input validation errors. This vulnerability stemmed from excessive slicing access within the CHF nchf-convergedcharging service, which could lea...

7.1CVSS6.4AI score0.00404EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2026/03/20 12:0 a.m.15 views

PT-2026-26700

The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent...

7.3CVSS5.8AI score0.0025EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2026/03/20 12:0 a.m.14 views

IGL-Technologies eParking.fi 安全漏洞

IGL-Technologies eParking.fi is an intelligent parking platform provided by IGL-Technologies, offering features for parking management, charging, and parking space monitoring. IGL-Technologies eParking.fi has a security vulnerability, as the identity verification identifier of the charging statio...

6.9CVSS5.8AI score0.00292EPSS
SaveExploits0References2
ICS
ICS
added 2026/03/19 5:0 a.m.9 views

IGL-Technologies eParking.fi

RISK EVALUATION Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. 2. RECOMMENDED PRACTICES CISA recommends users take defensive...

5.9AI score
SaveExploits0References11
ICS
ICS
added 2026/03/19 5:0 a.m.11 views

CTEK Chargeportal

RISK EVALUATION Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. 2. RECOMMENDED PRACTICES CISA recommends users take defensive...

5.9AI score
SaveExploits0References11
OSV
OSV
added 2026/03/18 5:26 p.m.29 views

GHSA-6G43-577R-WF4X Out-of-Bounds Slice Access in free5GC CHF Leading to DoS

Impact This is an out-of-bounds slice access vulnerability in the CHF nchf-convergedcharging service. A valid authenticated request to PUT /nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=... can trigger a server-side panic in github.com/free5gc/chf/internal/sbi.Server.RechargePut... due t...

7.1CVSS5.8AI score0.00404EPSS
SaveExploits0References6
Github Security Blog
Github Security Blog
added 2026/03/18 5:26 p.m.15 views

Out-of-Bounds Slice Access in free5GC CHF Leading to DoS

Impact This is an out-of-bounds slice access vulnerability in the CHF nchf-convergedcharging service. A valid authenticated request to PUT /nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=... can trigger a server-side panic in github.com/free5gc/chf/internal/sbi.Server.RechargePut... due t...

7.1CVSS5.8AI score0.00404EPSS
SaveExploits0References6Affected Software1
Packet Storm News
Packet Storm News
added 2026/03/18 12:0 a.m.5 views

Defending the Power Grid by Segmenting the EV Charging Cyber Infrastructure

This paper examines defending the power grid against load-altering attacks using electric vehicle charging. It proposes to preventively segment the cyber infrastructure that charging station operators CSOs use to communicate with and control their charging stations, thereby limiting the impact of...

5.7AI score
SaveExploits0
Positive Technologies
Positive Technologies
added 2026/03/18 12:0 a.m.10 views

PT-2026-26176

free5GC is an open source 5G core network. free5GC CHF prior to version 1.2.2 has an out-of-bounds slice access vulnerability in the CHF nchf-convergedcharging service. A valid authenticated request to PUT /nchf-convergedcharging/v3/recharging/:ueId?ratingGroup=... can trigger a server-side panic...

7.1CVSS5.8AI score0.00404EPSS
SaveExploits0References10
EUVD
EUVD
added 2026/03/10 6:31 p.m.5 views

EUVD-2025-208479

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station All versions F4.11.1, Heliox Mobile DC 40 kW EV Charging Station All versions L4.10.1. Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable...

2.6CVSS5.7AI score0.00141EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/03/10 6:31 p.m.3 views

EUVD-2025-208480

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station All versions F4.11.1, Heliox Mobile DC 40 kW EV Charging Station All versions L4.10.1. Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable...

2.6CVSS5.7AI score0.00141EPSS
SaveExploits0References2
NVD
NVD
added 2026/03/10 6:17 p.m.6 views

CVE-2025-27769

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station All versions F4.11.1, Heliox Mobile DC 40 kW EV Charging Station All versions L4.10.1. Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable...

2.6CVSS0.00141EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/03/10 4:7 p.m.27 views

CVE-2025-27769

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station All versions F4.11.1, Heliox Mobile DC 40 kW EV Charging Station All versions L4.10.1. Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable...

2.6CVSS0.00141EPSS
SaveExploits0References1
CNVD
CNVD
added 2026/03/10 12:0 a.m.7 views

Siemens Heliox EV Chargers Access Control Vulnerability

The Heliox Flex 180 kW EV Charging Station is a modular DC fast charging device in the Heliox series from Siemens.Heliox Mobile DC 40 kW EV Charging Station is a portable, plug-and-play fast charging device for electric vehicles from the Heliox brand of Siemens. The Heliox Mobile DC 40 kW EV...

2.6CVSS5.8AI score0.00141EPSS
SaveExploits0
Rows per page
Query Builder