479 matches found
CVE-2026-8987
CVE-2026-8987 affects Autel Maxi Charger Single firmware up to V1.03.51. The issue is a heap-based buffer overflow in the set_ap_param command handled by the /localcfg endpoint. An authenticated attacker can supply oversized input, leading to denial of service and potentially arbitrary code execu...
CVE-2026-8983
Autel Maxi Charger Single firmware through V1.03.51 contains a hard-coded authentication token that bypasses authorization checks for multiple management endpoints. An attacker can supply the special token value to invoke privileged functionality without valid authentication...
CVE-2026-8982
Two undocumented privileged accounts exist in Autel Maxi Charger Single firmware through V1.03.51. The accounts use vendor-defined password derivation mechanisms based on device-specific values, allowing an attacker with knowledge of the algorithm and required inputs to authenticate to the web...
CVE-2026-8986
Autel Maxi Charger Single firmware up to V1.03.51 is vulnerable to OS command injection when handling OCPP GetDiagnostics requests. A crafted diagnostics URL from a malicious or compromised OCPP server can trigger arbitrary command execution on the charging station. This CVE has a high-severity, ...
CVE-2026-8986
Autel Maxi Charger Single firmware through V1.03.51 is vulnerable to OS command injection when processing OCPP GetDiagnostics requests. A malicious or compromised OCPP server can supply a crafted diagnostics URL that results in arbitrary command execution on the charging station...
CVE-2026-8985
Autel Maxi Charger Single firmware through V1.03.51 is vulnerable to OS command injection in the /test endpoint exposed on TCP port 9002. An unauthenticated attacker can supply crafted input in the url parameter to execute arbitrary operating system commands...
CVE-2026-8985
CVE-2026-8985 affects Autel Maxi Charger Single firmware up to version 1.03.51. The vulnerability is an OS command injection in the /test endpoint exposed on TCP port 9002. An unauthenticated attacker can craft input in the URL parameter to execute arbitrary operating-system commands. The NVD ent...
CVE-2026-8984 Unauthenticated RCE
Autel Maxi Charger Single firmware through V1.03.51 allows unauthenticated remote code execution via the service listening on TCP port 9002. A crafted request to the /test endpoint can cause the device to download, extract, and execute attacker-controlled files with root privileges...
CVE-2026-8984
Autel Maxi Charger Single firmware up to version V1.03.51 is affected. The vulnerability allows unauthenticated remote code execution via a service listening on TCP port 9002. A crafted request to the /test endpoint can cause the device to download, extract, and execute attacker-controlled files ...
CVE-2026-8983
CVE-2026-8983 affects Autel Maxi Charger Single firmware up to v1.03.51. The root cause is a hard-coded authentication token that bypasses authorization checks across multiple management endpoints, enabling an attacker to invoke privileged functionality without valid authentication. Impact, per a...
CVE-2026-8983 Backdoor Authentication Token
Autel Maxi Charger Single firmware through V1.03.51 contains a hard-coded authentication token that bypasses authorization checks for multiple management endpoints. An attacker can supply the special token value to invoke privileged functionality without valid authentication...
CVE-2026-8982 Hard-coded / Backdoor Accounts
Two undocumented privileged accounts exist in Autel Maxi Charger Single firmware through V1.03.51. The accounts use vendor-defined password derivation mechanisms based on device-specific values, allowing an attacker with knowledge of the algorithm and required inputs to authenticate to the web...
CVE-2026-8982
Two undocumented privileged accounts exist in Autel Maxi Charger Single firmware (through version V1.03.51) enabling administrative access to the web management interface. The accounts rely on vendor-defined password derivation mechanisms based on device-specific values, requiring knowledge of th...
PT-2026-62120
Two undocumented privileged accounts exist in Autel Maxi Charger Single firmware through V1.03.51. The accounts use vendor-defined password derivation mechanisms based on device-specific values, allowing an attacker with knowledge of the algorithm and required inputs to authenticate to the web...
PT-2026-62121
Autel Maxi Charger Single firmware through V1.03.51 contains a hard-coded authentication token that bypasses authorization checks for multiple management endpoints. An attacker can supply the special token value to invoke privileged functionality without valid authentication...
PT-2026-62419
Autel Maxi Charger Single firmware through V1.03.51 exposes an accessible UART interface that permits interruption of the boot process and access to the U-Boot bootloader. An attacker with physical access can modify the boot configuration or file system to obtain operating system access...
PT-2026-62417
Autel Maxi Charger Single firmware through V1.03.51 is vulnerable to OS command injection when processing OCPP GetDiagnostics requests. A malicious or compromised OCPP server can supply a crafted diagnostics URL that results in arbitrary command execution on the charging station...
PT-2026-62416
Autel Maxi Charger Single firmware through V1.03.51 is vulnerable to OS command injection in the /test endpoint exposed on TCP port 9002. An unauthenticated attacker can supply crafted input in the url parameter to execute arbitrary operating system commands...
CVE-2026-9039
A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default...
CVE-2026-9039 Initialization of a resource with an insecure default in XCharge C6
A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default...