338 matches found
CVE-2022-26034
The CVE-2022-26034 issue affects Yokogawa CENTUM VP family and B/M9000 VP (notably CENTUM VP R6.01.10–R6.09.00; B/M9000 VP R8.01.01–R8.03.01; and ProSafe-RS up to R4.07.00 if RS4E5000 is installed). The root cause is improper authentication in the AD server’s communication protocol, enabling an a...
Yokogawa Electric和Yokogawa Electric CENTUM VP 操作系统操作系统命令注入漏洞
Yokogawa Electric is a server from Yokogawa, Japan.Yokogawa Electric CENTUM VP is a CENTUM distributed control system from Yokogawa Electric, Japan. Setting high standards for engineering and technical excellence while ensuring backward compatibility with previous system versions and support for...
Yokogawa Electric CENTUM VP 授权问题漏洞
The Yokogawa Electric CENTUM VP is a CENTUM distributed control system from Yokogawa Electric. Setting high standards for engineering and technical excellence while ensuring backward compatibility with previous system versions and support for the latest technology applications. A security...
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to execute arbitrary commands.
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to authentication process flaws. Exploiting this vulnerability could allow attackers...
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to write arbitrary files.
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to errors in processing the relative path to the catalog. Exploiting this...
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to increase their privileges.
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, stems from the use of rigidly encoded user credentials. Exploiting this vulnerability could all...
Yokogawa CENTUM and Exaopc Use of Hard-Coded Credentials (CVE-2022-21194)
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00. This plugin only works with...
Yokogawa CENTUM and Exaopc Use of Hard-Coded Credentials (CVE-2022-23402)
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00 This plugin only works with Tenable.ot. Please visit...
Yokogawa CENTUM and Exaopc
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Yokogawa Equipment: CENTUM and Exaopc Vulnerabilities: Use of Hard-coded Credentials, Relative Path Traversal, Improper Output Neutralization for Logs, OS Command Injection, Permissions, Privileges...
Yokogawa CENTUM and Exaopc Uncontrolled Search Path Element (CVE-2022-23401)
The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. This plugin only work...
Yokogawa CENTUM and Exaopc Improper Output Neutralization For Logs (CVE-2022-21177)
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from...
Yokogawa CENTUM and Exaopc Permissions, Privileges, and Access Controls (CVE-2022-22141)
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 t...
Yokogawa CENTUM and Exaopc Relative Path Traversal (CVE-2022-21808)
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.0...
Yokogawa CENTUM and Exaopc Improper Neutralization of Special Elements Used in an OS Command (CVE-2022-22148)
'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc...
Yokogawa CENTUM and Exaopc Relative Path Traversal (CVE-2022-22729)
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to...
Vulnerabilities fixed in Yokogawa CENTUM VP
Vulnerabilities have been fixed in Yokogawa CENTUM VP. The vulnerabilities allow a malicious person to carry out attacks that result in the following categories of damage: Denial-of-Service DoS. Manipulation of data Circumvention of security measure Remote code execution Administrator/Root rights...
CVE-2022-22141
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 t...
CVE-2022-21177
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from...
CVE-2022-22151
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions fr...
CVE-2022-21808
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.0...