EUVD-2021-30481
Malicious code in bioql PyPI...
CVE-2020-16218
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
CVE-2021-43552 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX PIC iX Versions B.02, C.02, and C.03...
Philips Patient Information Center iX 安全漏洞
Philips Patient Information Center iX Philips Patient Information Center PIC iX, a Philips company in Europe, is at the heart of our patient monitoring system, which facilitates understanding of the patient's condition and helps caregivers to identify potential deterioration at an early stage, as...
CVE-2020-16220
In Patient Information Center iX PICiX Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed i.e., to comply with a certain syntax but it does not validate or incorrectly validates that the input complies with the syntax,...
Code injection
In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...
CVE-2020-16228
In Patient Information Center iX PICiX Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate...
CVE-2020-16218
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
CVE-2020-16220
The CVE-2020-16220 issue affects Philips PICiX (Versions C.02, C.03) and PerformanceBridge Focal Point (Version A.01). It stems from improper validation of input to the certificate enrollment service, where inputs expected to conform to a syntax are not properly validated, causing the certificate...
CVE-2020-16228
CVE-2020-16228 affects Philips PICiX (PIC iX) Versions C.02/C.03, PerformanceBridge Focal Point A.01, IntelliVue monitors MX100/MX400-MX850 and MP2-MP90, and IntelliVue X3 Versions N and prior. The issue is improper or missing certificate revocation checking, which may cause the device to trust a...
CVE-2020-16218 Philips Patient Monitoring Devices Cross-site Scripting
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
PT-2020-14827 · Philips · Patient Information Center Ix +2
Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions C.02 and C.03 PerformanceBridge Focal Point version A.01 IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850 IntelliVue X3 versions N and prior Description: The software does not check or...