49 matches found
CVE-2021-31346
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions, SIMOTICS CONNECT 400 All versions V0.5.0.0, SIMOTICS CONNECT 400 All versions V1.0.0.0. The total length of an ICMP...
CVE-2021-31883
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303. When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor options, leading to Denial-of-Service...
CVE-2021-31344
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions, SIMOTICS CONNECT 400 All versions V0.5.0.0, SIMOTICS CONNECT 400 All versions V1.0.0.0. ICMP echo packets with fake IP...
CVE-2021-31345
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions. The total length of an UDP payload set in the IP header is unchecked. This may lead to various side effects, including...
CVE-2021-31882
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303. The DHCP client application does not validate the length of the Domain Name Server IP options 0x06 when processing DHCP ACK packets. This may lead to...
CVE-2021-31881
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303. When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor options, leading to Denial-of-Service...
CVE-2021-31889
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions, SIMOTICS CONNECT 400 All versions V0.5.0.0. Malformed TCP packets with a corrupted SACK option leads to Information Lea...
CVE-2021-31345
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions. The total length of an UDP payload set in the IP header is unchecked. This may lead to various side effects, including...
CVE-2021-31889
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, PLUSCONTROL 1st Gen All versions, SIMOTICS CONNECT 400 All versions V0.5.0.0. Malformed TCP packets with a corrupted SACK option leads to Information Lea...
PT-2021-6896 · Unknown +1 · Nucleus Source Code +10
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions all APOGEE MBC versions all APOGEE MEC versions all APOGEE PXC versions all TALON TC versions all Nucleus...
PT-2021-19563 · Unknown · Capital Embedded Ar Classic R20-11 +1
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions all prior to V2303 Description: A vulnerability has been identified where the DHCP client application does not validate the length of the Domain Name...
PT-2021-19251 · Siemens +1 · Simotics Connect 400 +12
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions all prior to V2303 PLUSCONTROL 1st Gen versions all SIMOTICS CONNECT 400 versions all prior to V0.5.0.0 SIMOTICS CONNECT 400 versions all prior to...
PT-2021-19564 · Unknown · Nucleus Readystart V3 +9
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions prior to V2303 Capital Embedded AR Classic R20-11 versions prior to V2303 APOGEE MBC PPC BACnet all versions APOGEE MBC PPC P2 Ethernet all versions APOGEE MEC PPC BACnet all versions APOGEE MEC PP...
PT-2021-6895 · Mentor Graphics +1 · Nucleus Net +9
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions prior to V2303 Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions prior to the fixed version SIMOTICS CONNECT 400 versions prior to V0.5.0.0 SIMOTICS CONNECT 40...
PT-2021-7827 · Unknown · Capital Embedded Ar Classic R20-11 +1
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions prior to V2303 Description: A Denial-of-Service condition can occur due to the DHCP client application not validating the length of the Vendor option...
PT-2021-6242 · Mentor Graphics +1 · Nucleus Net +11
Name of the Vulnerable Software and Affected Versions: Capital Embedded AR Classic 431-422 versions all Capital Embedded AR Classic R20-11 versions prior to V2303 PLUSCONTROL 1st Gen versions all SIMOTICS CONNECT 400 versions prior to V0.5.0.0 APOGEE MBC versions all APOGEE MEC versions all APOGE...
CVE-2021-25663
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, Nucleus NET All versions, Nucleus ReadyStart V3 All versions V2017.02.4, Nucleus ReadyStart V4 All versions V4.1.0, Nucleus Source Code All versions...
CVE-2021-25663
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, Nucleus NET All versions, Nucleus ReadyStart V3 All versions V2017.02.4, Nucleus ReadyStart V4 All versions V4.1.0, Nucleus Source Code All versions...
CVE-2021-25664
A vulnerability has been identified in Capital Embedded AR Classic 431-422 All versions, Capital Embedded AR Classic R20-11 All versions V2303, Nucleus NET All versions, Nucleus ReadyStart V3 All versions V2017.02.4, Nucleus ReadyStart V4 All versions V4.1.0, Nucleus Source Code All versions...
Input validation