CVE-2024-39601
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.40, SICORE Base system All versions V1.4.0. Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow a...
CVE-2024-39601
CVE-2024-39601 affects CPCI85 Central Processing/Communication (all versions before V5.40) and SICORE Base system (all versions before V1.4.0). The root cause is missing authentication for a critical function that allows firmware downgrades, enabling remote authenticated users or unauthenticated ...
CVE-2024-37998
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.40, SICORE Base system All versions V1.4.0. The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto logi...
CVE-2024-37998
CVE-2024-37998 affects Siemens CPCI85 Central Processing/Communication (all versions < V5.40) and SICORE Base system (all versions
CVE-2024-37998
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.40, SICORE Base system All versions V1.4.0. The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto logi...
CVE-2024-39601: Missing Authentication for Critical Function
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.40, SICORE Base system All versions V1.4.0. Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow a...
PT-2024-5126 · Unknown · Cpci85 Central Processing/Communication +1
Name of the Vulnerable Software and Affected Versions: CPCI85 Central Processing/Communication versions prior to V5.40 SICORE Base system versions prior to V1.4.0 Description: A vulnerability has been identified that allows a remote authenticated user or an unauthenticated user with physical acce...
CVE-2024-37998: Unverified Password Change
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.40, SICORE Base system All versions V1.4.0. The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto logi...
Siemens SICAM Products
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2024-31484
A vulnerability has been identified in CPC80 Central Processing/Communication All versions V16.41, CPCI85 Central Processing/Communication All versions V5.30, CPCX26 Central Processing/Communication All versions V06.02, ETA4 Ethernet Interface IEC60870-5-104 All versions V10.46, ETA5 Ethernet Int...
CVE-2024-31485
CVE-2024-31485 affects CPCI85 Central Processing/Communication (all versions < V5.30) and SICORE Base system (all versions
CVE-2024-31485
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.30, SICORE Base system All versions V1.3.0. The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated...
CVE-2024-31484
A vulnerability has been identified in CPC80 Central Processing/Communication All versions V16.41, CPCI85 Central Processing/Communication All versions V5.30, CPCX26 Central Processing/Communication All versions V06.02, ETA4 Ethernet Interface IEC60870-5-104 All versions V10.46, ETA5 Ethernet Int...
CVE-2024-31484
CVE-2024-31484 affects Siemens SICAM family: CPC80, CPCI85, CPCX26, ETA4, ETA5, PCCX26 (various versions prior to the listed fixed releases). Root cause is improper null termination when parsing a specific HTTP header, enabling code execution in the current process or a denial-of-service conditio...
CVE-2024-31484: Improper Null Termination
A vulnerability has been identified in CPC80 Central Processing/Communication All versions V16.41, CPCI85 Central Processing/Communication All versions V5.30, CPCX26 Central Processing/Communication All versions V06.02, ETA4 Ethernet Interface IEC60870-5-104 All versions V10.46, ETA5 Ethernet Int...
CVE-2024-31485: Improper Neutralization of Special Elements used in a Command
A vulnerability has been identified in CPCI85 Central Processing/Communication All versions V5.30, SICORE Base system All versions V1.3.0. The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated...
Siemens SICAM Products
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens CPCI85 Firmware of SICAM A8000 Devices Command Injection Vulnerability
The SICAM A8000 rtu remote terminal unit series is a modular family of devices for remote control and automation applications in all areas of energy supply. A command injection vulnerability exists in the Siemens CPCI85 Firmware of SICAM A8000 Devices, which can be exploited by an authenticated,...
Siemens SICAM A8000 Device CPCI85 Firmware Hardcoded Credentials Vulnerability
The SICAM A8000 RTU Remote Terminal Unit series is a modular family of devices for remote control and automation applications in all areas of energy supply. A hard-coded credentials vulnerability exists in the CPCI85 firmware of the Siemens SICAM A8000 device, which can be exploited by an attacke...
Siemens SICAM A8000 Device CPCI85 Firmware Web Server Path Traversal Vulnerability
The ICAM A8000 RTU Remote Terminal Unit series is a modular family of devices for remote control and automation applications in all areas of energy supply. A path traversal vulnerability exists in the Siemens SICAM A8000 device CPCI85 firmware web server, which can be exploited by an attacker to...