175 matches found
CVE-2022-29303
CVE-2022-29303-Exploit Exploit per CVE-2022-29303 Utilizzo Controlla un singolo host root@kitploit: / \ \ / / || \ | \ // \ / | \ V /| |/ / / / / // /, /| \ | \ | / || ///| /|//|/// Coded By Valentin Lobstein "With great power comes great responsibility" usage: CVE-2022-29303.py -h -u URL -c...
CVE-2023-40924
BUGAuthor: YE Versione affetta: Contec SolarView Compact 6.00 Vendor: https://www.contecinc.com/ Vulnerability File: downloader.php Descrizione: L'attaccante sfrutta la vulnerabilità tramite downloader.php? Il parametro file legge file sensibili attraverso il path traversal. downloader.php?file...
SolarView Compact 6.00 - OS Command Injection
SolarView Compact 6.00 was discovered to contain a command injection vulnerability via confmail.php. id: CVE-2022-29303 info: name: SolarView Compact 6.00 - OS Command Injection author: badboycxcc severity: critical description: | SolarView Compact 6.00 was discovered to contain a command injecti...
SolarView Compact 6.00 - Cross-Site Scripting
SolarView Compact 6.00 contains a cross-site scripting vulnerability via SolarAiConf.php. An attacker can execute arbitrary script in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch...
SolarView 6.00 - Remote Command Execution
SolarView Compact 6.00 is vulnerable to a command injection via networktest.php. id: CVE-2022-40881 info: name: SolarView 6.00 - Remote Command Execution author: For3stCo1d severity: critical description: | SolarView Compact 6.00 is vulnerable to a command injection via networktest.php. impact: |...
SolarView Compact 6.00 - OS Command Injection
SolarView Compact 6.00 was discovered to contain a command injection vulnerability, attackers can execute commands by bypassing internal restrictions through downloader.php. id: CVE-2023-23333 info: name: SolarView Compact 6.00 - OS Command Injection author: Mr-xn severity: critical description: ...
SolarView Compact <= 6.00 - Local File Inclusion
There is an arbitrary read file vulnerability in SolarView Compact 6.00 and below, attackers can bypass authentication to read files through texteditor.php id: CVE-2023-29919 info: name: SolarView Compact = 6.00 - Local File Inclusion author: For3stCo1d severity: critical description: | There is ...
SolarView Compact 6.00 - Local File Inclusion
SolarView Compact 6.00 is vulnerable to local file inclusion which could allow attackers to access sensitive files. id: CVE-2022-29298 info: name: SolarView Compact 6.00 - Local File Inclusion author: ritikchaddha severity: high description: SolarView Compact 6.00 is vulnerable to local file...
VulnCheck KEV: CVE-2024-12248
Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...
VulnCheck KEV: CVE-2025-0683
In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...
CVE-2018-9162
Contec Smart Home 4.15 devices do not require authentication for newuser.php, edituser.php, deleteuser.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors...
EUVD-2018-20759
Malware in sbrugna...
EUVD-2023-34216
Malicious code in bioql PyPI...
EUVD-2025-19659
Malicious code in bioql PyPI...
EUVD-2022-38878
Malicious code in bioql PyPI...
EUVD-2022-38879
Malicious code in bioql PyPI...
EUVD-2025-19656
Malicious code in bioql PyPI...
EUVD-2024-50712
Malicious code in bioql PyPI...
EUVD-2023-50715
Malicious code in bioql PyPI...
CVE-2025-34080
The Contec Co.,Ltd. CONPROSYS HMI System CHS is vulnerable to Cross-Site Scripting XSS in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System CHS: before 3.7.7...