124 matches found
CVE-2025-34081 CONPROSYS HMI System (CHS) < 3.7.7 Exposed PHP Debug Info
The Contec Co.,Ltd. CONPROSYS HMI System CHS exposes a PHP phpinfo debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System CHS: before 3.7.7...
CVE-2025-34080
CVE-2025-34080 affects Contec Co.,Ltd. CONPROSYS HMI System (CHS) versions before 3.7.7. The issue is a reflected Cross-Site Scripting (XSS) in the getqsetting.php functionality, enabling execution of browser scripts on interaction. The vulnerability’s impact is browser-side script execution for ...
CVE-2025-34080 CONPROSYS HMI System (CHS) < 3.7.7 Reflected Cross-Site Scripting
The Contec Co.,Ltd. CONPROSYS HMI System CHS is vulnerable to Cross-Site Scripting XSS in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System CHS: before 3.7.7...
CVE-2025-34080 CONPROSYS HMI System (CHS) < 3.7.7 Reflected Cross-Site Scripting
The Contec Co.,Ltd. CONPROSYS HMI System CHS is vulnerable to Cross-Site Scripting XSS in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System CHS: before 3.7.7...
PT-2025-27565 · Unknown · Conprosys Hmi System
Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions prior to 3.7.7 Description: The issue is related to Cross-Site Scripting XSS in the getqsetting.php functionality, which could allow reflected execution of scripts in the browser on interaction...
Contec CONPROSYS HMI System 安全漏洞
Contec CONPROSYS HMI System is an HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product based on HTML5 technology from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.7.7, which stems from cross-site scripting ...
PT-2025-27566 · Unknown · Conprosys Hmi System
Name of the Vulnerable Software and Affected Versions: CONPROSYS HMI System CHS versions prior to 3.7.7 Description: The issue concerns the exposure of a PHP phpinfo debug page to unauthenticated users, potentially containing sensitive data useful for an attacker. Recommendations: For versions...
CVE-2023-28657
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-22339
Improper access control vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product...
CVE-2023-22373
Cross-site scripting vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information...
CVE-2023-28824
Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...
CVE-2023-28713
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...
CVE-2023-28651
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
CVE-2023-22331
Use of default credentials vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information...
CVE-2023-22324
SQL injection vulnerability in the CONPROSYS HMI System CHS Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained...
CVE-2023-22334
Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack...
CVE-2022-44456
CONPROSYS HMI System CHS Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request...
The vulnerability of HMI/SCADA CONPROSYS HMI, which stems from insufficient verification of incoming requests, allows a hacker to perform an SSRF attack.
The vulnerability of HMI/SCADA CONPROSYS HMI is related to insufficient checking of incoming requests. Exploiting this vulnerability can allow a malicious actor to perform an SSRF attack remotely...
CVE-2023-28713
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...