14169 matches found
CVE-2023-29103
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1, SIMATIC Cloud Connect 7 CC716 All versions V2.1. The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected dat...
CVE-2023-28832
Siemens SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) and CC716 (6GK1411-5AC00) are affected for versions 2.0 to 2.1. The issue is a web-based management input validation flaw that enables command injection, allowing an authenticated privileged remote attacker to execute arbitrary code with root ...
CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to...
CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 All versions = V2.0 = V2.0 V2.1. The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to...
kernel: use-after-free caused by invalid pointer hostname in fs/cifs/connect.c
A use-after-free flaw was found in reconnsetipaddrfromhostname in fs/cifs/connect.c in the Linux kernel. The issue occurs when it forgets to set the free pointer server-hostname to NULL, leading to an invalid pointer request...
kernel: RDMA/siw: Fix duplicated reported IW_CM_EVENT_CONNECT_REPLY event
In the Linux kernel, the following vulnerability has been resolved: RDMA/siw: Fix duplicated reported IWCMEVENTCONNECTREPLY event If siwrecvmparr returns -EAGAIN, it means that the MPA reply hasn't been received completely, and should not report IWCMEVENTCONNECTREPLY in this case. This may trigge...
kernel: use-after-free in l2cap_connect and l2cap_le_connect_req in net/bluetooth/l2cap_core.c
A use-after-free flaw was found in the Linux kernel's implementation of logical link control and adaptation protocol L2CAP, part of the Bluetooth stack in the l2capconnect and l2capleconnectreq functions. An attacker with physical access within the range of standard Bluetooth transmission could...
PT-2023-21995 · Siemens · Simatic Cloud Connect 7 Cc712 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description: A vulnerability has been identified where the web-based management of affected devices does not properly validate user...
Siemens SIMATIC Cloud Connect 路径遍历漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A path traversal vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited by a...
Siemens SIMATIC Cloud Connect 信息泄露漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. An information disclosure vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in SIMATIC Cloud Connect, Siveillance, SINEC, Solid Edge and Scalance products. The vulnerabilities potentially enable a malicious party to launch attacks execute attacks that could result in the following categories of damage: Denial-of-Service DoS Manipulation ...
PT-2023-22155 · Siemens · Simatic Cloud Connect 7 Cc712 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1 Description: A vulnerability has been identified that could allow an unauthenticated remote attacker to gain access to additional...
Intel® Connect M Android App Advisory
Summary: Potential security vulnerabilities in the Intel® Connect M Android application may allow escalation of privilege or denial of service. Intel is releasing software updates to mitigate these potential vulnerabilities. Vulnerability Details: CVEID: CVE-2022-41801 Description: Uncontrolled...
PT-2025-25905 · Linux +1 · Linux Kernel +1
Name of the Vulnerable Software and Affected Versions: Linux kernel versions prior to 5.18.0 Description: A refcount bug in the Linux kernel has been resolved. The issue occurs during the SMC fallback process in the connect syscall, where the kernel replaces TCP with SMC and sets the clcsk-sk use...
PT-2023-22162 · Siemens · Simatic Cloud Connect 7 Cc712 +1
Name of the Vulnerable Software and Affected Versions: SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.0 SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.0 Description: A path traversal vulnerability has been identified in the upload feature of the web-based management of the affected...
Siemens SIMATIC Cloud Connect安全漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A denial of service vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited b...
Siemens SIMATIC Cloud Connect 路径遍历漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A path traversal vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited by a...
Siemens SIMATIC Cloud Connect 安全漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. An information disclosure vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be...
Siemens SIMATIC Cloud Connect 7
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SIMATIC Cloud Connect 命令注入漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A command injection vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited b...