1857 matches found
EUVD-2026-126937
The CODESYS Automation Server Connector uses server-supplied file names without sufficient path traversal checks. An unauthenticated remote attacker controlling a malicious Automation Server and tricking a user to trust it, or performing a man-in-the-middle attack on a trusted communication...
EUVD-2026-126936
The affected products do not sufficiently validate CODESYS Automation Server TLS certificates when a user starts the certificate enrollment. An unauthenticated remote attacker performing a man-in-the-middle attack can exploit this vulnerability by supplying an untrusted certificate that is accept...
CVE-2026-118498
The CODESYS Automation Server Connector is vulnerable to a path traversal flaw because it processes server-supplied file names without sufficient validation. An unauthenticated remote attacker could exploit this by controlling a malicious Automation Server and tricking a user into trusting it, or...
CVE-2026-118497
The CODESYS Automation Server Connector and CODESYS Service Tool are vulnerable to improper certificate validation during the certificate enrollment process. An unauthenticated remote attacker can perform a man-in-the-middle (MITM) attack by providing an untrusted certificate that the system inco...
ICSFuzz
ICSFuzz: Fuzzing Tool for ICS Control Applications Overview ICSFuzz is an PLC-side fuzzing tool for uncovering vulnerabilities in ICS control applications by Dimitris Tychalas @ditihala .. @ditihala: https://www.twitter.com/ditihala Installation The tool requires an already existing cross...
CVE-2026-76992
The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a...
CVE-2026-76992 Uncontrolled Memory Allocation in CODESYS Gateway Client
The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a...
EUVD-2026-89776
The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a...
CVE-2026-76992
The CODESYS Gateway Client is vulnerable to a denial-of-service condition because it allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker who controls a malicious gateway can exploit this behavior to trigger ...
CVE-2026-79625 Improper Synchronization in Monitoring in CODESYS Control Runtime
Affected products do not properly synchronize access to their monitoring functionality. When multiple clients send concurrent requests, this may lead to incorrect reads or writes, or to corruption of internal memory structures. An authenticated remote attacker with monitoring access can exploit...
CVE-2026-79625
The CODESYS Control Runtime is vulnerable to an improper synchronization flaw within its monitoring functionality. When multiple clients submit concurrent requests, the system fails to properly synchronize access, potentially resulting in incorrect reads or writes or the corruption of internal me...
CVE-2026-76992: Allocation of Resources Without Limits or Throttling
The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a...
PT-2026-103119
The CODESYS Gateway Client allocates memory based on a size field in a gateway response without enforcing an appropriate upper limit. An unauthenticated remote attacker controlling a malicious gateway can exploit this behavior to trigger excessive memory consumption, resulting in a...
CVE-2026-35226
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...
CVE-2026-35226 Out-of-bounds Write in CODESYS PROFINET Controller
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...
CVE-2026-35226
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...
EUVD-2026-50166
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...
CVE-2026-35226
CVE-2026-35226 describes an out-of-bounds write in the CODESYS PROFINET Controller . An unauthenticated attacker on the same network can send malformed PROFINET data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime system and resu...
CVE-2026-35226 Out-of-bounds Write in CODESYS PROFINET Controller
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...
CVE-2026-35226: Out-of-bounds Write
An out‑of‑bounds write vulnerability in the CODESYS PROFINET Controller allows an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application. The exception is handled by the CODESYS Control runtime...