Tenable Nessus
•added 2025/04/14 12:00 a.m.•15 views

Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-11499)

A vulnerability exists in RTU500 IEC 60870-4-104 con- trolled station functionality, that allows an authenti- cated and authorized attacker to perform a CMU re- start. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will...

8.7CVSS5.4AI score0.00397EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
•added 2025/03/27 1:36 p.m.•19 views

CVE-2024-11499

A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...

6.9CVSS6.6AI score0.00244EPSS
SaveExploits0References1
NVD
NVD
•added 2025/03/25 1:15 p.m.•21 views

CVE-2024-11499

A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...

6.9CVSS0.00244EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/03/25 12:36 p.m.•25 views

CVE-2024-12169

A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...

8.7CVSS0.00397EPSS
SaveExploits0References1
CVE
CVE
•added 2025/03/25 12:36 p.m.•81 views

CVE-2024-12169

The CVE-2024-12169 entry involves Hitachi Energy RTU500 series, affecting the RTU500 IEC 60870-5-104 controlled-station functionality and IEC 61850 functionality. The described impact is that an attacker performing a specific attack sequence can restart the affected CMU, and this only applies whe...

8.7CVSS7AI score0.00397EPSS
SaveExploits0References1
CVE
CVE
•added 2025/03/25 12:30 p.m.•71 views

CVE-2024-11499

CVE-2024-11499 – Hitachi Energy RTU500 : The RTU500 IEC 60870-4-104 controlled-station functionality is affected. An authenticated and authorized attacker can trigger a CMU restart by updating certificates while they are in use on active connections. The affected CMU is described as automatically...

6.9CVSS6.8AI score0.00244EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/03/25 12:30 p.m.•34 views

CVE-2024-11499

A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...

6.9CVSS0.00244EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/03/25 12:30 p.m.•11 views

CVE-2024-11499

A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...

6.9CVSS6.8AI score0.00244EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/25 12:00 a.m.•0 views

CVE-2024-11499: NULL Pointer Dereference

A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically...

6.9CVSS5.8AI score0.00244EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/03/25 12:00 a.m.•1 views

CVE-2024-12169: Undefined Security Weakness

A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 TLS is enabled...

8.7CVSS5.7AI score0.00397EPSS
SaveExploits0References1