Unspecified Vulnerability in Hitachi Energy RTU500 series CMU Firmware (CNVD-2025-02734)
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A security vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which can be exploited by attackers to bypass security updates...
Unspecified Vulnerability in Hitachi Energy RTU500 series CMU Firmware (CNVD-2025-02735)
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A security vulnerability exists in Hitachi Energy RTU500 series CMU Firmware versions 12.0.1 through 12.0.14, which is caused due to a problem in the handling of stb language files,...
Hitachi Energy RTU500 安全漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A security vulnerability exists in Hitachi Energy RTU500 series CMU Firmware versions 12.0.1 through 12.0.14, which is caused due to a problem in the handling of stb language files,...
Hitachi Energy RTU500 series CMU Firmware Cross-Site Scripting Vulnerability (CNVD-2025-02739)
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from user input not being properly cleaned, and can be exploited by an...
Hitachi Energy RTU500 跨站脚本漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from user input not being properly cleaned, and can be exploited by an...
Hitachi Energy RTU500 series CMU Firmware Denial of Service Vulnerability
Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Japan. A denial of service vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which arises from an incomplete or incorrect layout of received APDU frames, and can be exploited by an attacker to cause ...
Hitachi Energy RTU500 跨站脚本漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from an RDT language file that is not properly cleaned up, and can be...
Hitachi Energy RTU500 跨站脚本漏洞
Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Japan. A denial of service vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which arises from an incomplete or incorrect layout of received APDU frames, and can be exploited by an attacker to cause ...
ABB RTU500 Series Infinite Loop in embedded OpenSSL (CVE-2022-0778)
A vulnerability exists in the OpenSSL version 1.0.2 that affects the RTU500 Series product versions listed below. RTU500 series CMU Firmware versions 12.0.1 â 12.0.14 12.2.1 â 12.2.11 12.4.1 â 12.4.11 12.6.1 â 12.6.8 12.7.1 â 12.7.5 13.2.1 â 13.2.5 13.3.1 â 13.3.3 13.4.1 The BNmodsq...
Hitachi Energy RTU500 series Improper Input Validation (CVE-2022-28613)
A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy...
Hitachi Energy RTU500 series CMU firmware buffer overflow vulnerability
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A buffer overflow vulnerability exists in the Hitachi Energy RTU500 series CMU firmware HCI Modbus TCP function. The vulnerability, which originates when HCI Modbus TCP is enabled a...
Hitachi Energy RTU500 安全漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A buffer overflow vulnerability exists in the Hitachi Energy RTU500 series CMU firmware HCI Modbus TCP function. The vulnerability, which originates when HCI Modbus TCP is enabled a...
CVE-2022-28613
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...
Information disclosure
A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy...
CVE-2022-28613
Hitachi Energy RTU500 CMU Firmware versions 12.0.–13.2. are affected by CVE-2022-28613 due to a validation error in the MBAP header length handling in the HCI Modbus TCP function. Exploitation could cause a reboot of the RTU500 CMU when HCI Modbus TCP is enabled, with CVSS v3.1 base score 7.5 (NE...
CVE-2022-28613 Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...
Hitachi Energy RTU500 OpenLDAP
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Type Confusion, Reachable Assertion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition...
Hitachi Energy RTU500 series BCI
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Bidirectional Communication Interface BCI Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a...
CVE-2021-35533
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface BCI IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted messag...
PT-2021-20956 · Hitachi Energy · Rtu500 Series Cmu Firmware
Name of the Vulnerable Software and Affected Versions: Hitachi Energy RTU500 series CMU Firmware version 12.0. Hitachi Energy RTU500 series CMU Firmware version 12.2. Hitachi Energy RTU500 series CMU Firmware version 12.4. Description: The issue is related to an Improper Input Validation...