221 matches found
Crestron 3-Series 安全漏洞
Crestron 3-Series is an enterprise-class control system for residential, commercial, and government applications from Crestron, Inc. A security vulnerability exists in Crestron 3-Series Control Systems prior to version 1.8001.0187, which stems from a specific BACnet packet that could cause a syst...
SAUTER EY-modulo 5 Building Automation Stations
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: SAUTER Equipment: EY-modulo 5 Building Automation Stations Vulnerabilities: Cross-site Scripting, Cleartext Transmission of Sensitive Information, and Unrestricted Upload of File with Dangerous Type 2...
SAUTER EY-modulo 5 Building Automation Station 代码问题漏洞
SAUTER EY-modulo 5 Building Automation Station is a complete building management solution from SAUTER. A security vulnerability exists in SAUTER EY-modulo 5 Building Automation Station. An authenticated attacker could exploit the vulnerability to upload a malicious image, resulting in a denial of...
SAUTER EY-modulo 5 Building Automation Station 跨站脚本漏洞
SAUTER EY-modulo 5 Building Automation Station is a complete building management solution from SAUTER. A security vulnerability exists in SAUTER EY-modulo 5 Building Automation Station. An attacker can exploit the vulnerability to execute malicious JavaScript in the target's security environment...
SAUTER EY-modulo 5 Building Automation Station 跨站脚本漏洞
SAUTER EY-modulo 5 Building Automation Station is a complete building management solution from SAUTER. A security vulnerability exists in SAUTER EY-modulo 5 Building Automation Station. An attacker can exploit the vulnerability to force all authenticated users to perform unauthorized actions by...
SAUTER EY-modulo 5 Building Automation Station 安全漏洞
SAUTER EY-modulo 5 Building Automation Station is a complete building management solution from SAUTER. A security vulnerability exists in SAUTER EY-modulo 5 Building Automation Station, which results from sensitive information being transmitted in clear text...
Real Time Automation 460MCBS 5.2.14 Cross Site Scripting
Exploit Title: Real Time Automation 460MCBS Cross Site Scripting XSS Date: 2023-03-09 Exploit Author: Yehia Elghaly Vendor Homepage: https://www.rtautomation.com/ Software Link: https://www.rtautomation.com/product/460mcbs/ Version: Revision 5.2.14 Tested on: Real Time Automation CVE: N/A Summary...
Cross-site scripting vulnerability in Import Files function of multiple Siemens products
Siemens Desigo PX is a building automation control system from Siemens, a German company. A cross-site scripting vulnerability exists in several Siemens products. The vulnerability stems from an incorrect neutralization of input during web page generation in the Import Files function of the...
Cross-site Request Forgery Vulnerability in Import Files Function of Multiple Siemens Products
Siemens Desigo PX is a building automation control system from Siemens, a German company. A cross-site request forgery vulnerability exists in several Siemens products, stemming from a lack of validation of anti-CSRF tokens or other source checks in the Import Files feature of the "Operation" Web...
Information leakage vulnerability of multiple Siemens products
Siemens Desigo PX is a building automation control system from Siemens, a German company. The information disclosure vulnerability in several Siemens products stems from the fact that the endpoint of the "Operation" web application that interprets and executes Axon language queries allows file re...
CVE-2022-30312
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller IC protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller...
Default credentials
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller IC protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller...
CVE-2022-30312
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller IC protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller...
CVE-2022-30312
The CVE-2022-30312 issue affects Trend Controls IC protocol (Inter-Controller, 57612/UDP) and Honeywell Trend IQ Series controllers. A 4‑digit authentication PIN and optional credentials (0–30 chars) are transmitted in CLEARTEXT, enabling an attacker with local access to obtain credentials and po...
A Door Isn’t a Door When It’s Ajar - Part 3
A Door Isn’t a Door When It’s Ajar - Part III By Trellix · August 25, 2022 This story was also written by Steve Povolny and Sam Quinn Contents Installing OnGuard by Third Party Vendor Exploitation and Hacking the Planet! Putting it all Together Building the Final Demo System The Demo Lessons and...
Honeywell Alerton Ascent Control Module 安全漏洞
The Honeywell Alerton Ascent Control Module is a high performance, BACnet-compliant, integrated building controller and router from USAHoneywell. It can support BACnet/Ethernet, BACnet/IP and BACnet/MSTP. A security vulnerability exists in Honeywell Alerton Ascent Control Module ACM versions...
APT Hackers Targeting Industrial Control Systems with ShadowPad Backdoor
Entities located in Afghanistan, Malaysia, and Pakistan are in the crosshairs of an attack campaign that targets unpatched Microsoft Exchange Servers as an initial access vector to deploy the ShadowPad malware. Russian cybersecurity firm Kaspersky, which first detected the activity in mid-October...
CVE-2022-21938
Under certain circumstances, a vulnerability in Metasys ADS/ADX/OAS 10 versions prior to 10.1.5 and Metasys ADS/ADX/OAS 11 versions prior to 11.0.2 could allow a user to inject malicious code into the MUI Graphics web interface...
CVE-2022-21937
Under certain circumstances, a vulnerability in Metasys ADS/ADX/OAS 10 versions prior to 10.1.5 and Metasys ADS/ADX/OAS 11 versions prior to 11.0.2 could allow a user to inject malicious code into the web interface...
Trellix Threat Labs Uncovers Critical Flaws in Widely Used Building Access Control System
Trellix Threat Labs Uncovers Critical Flaws in Widely Used Building Access Control System By Trellix · June 9, 2022 This story was also written by Steve Povolny and Sam Quinn. Today at the Hardwear.io Security Trainings and Conference, Trellix Threat Labs is sharing new research into...