Lucene search
K

15 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2020-19885

Malware in sbrugna...

8.8CVSS8.7AI score0.00972EPSS
Exploits1References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2020-19887

Malware in sbrugna...

6.5CVSS6.5AI score0.00588EPSS
Exploits1References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2017-3193

Malware in sbrugna...

5.9CVSS5.9AI score0.02049EPSS
Exploits1References5
EUVD
EUVD
added 2025/10/07 12:30 a.m.6 views

EUVD-2017-3194

Malware in sbrugna...

7.1CVSS7AI score0.01559EPSS
Exploits1References5
OSV
OSV
added 2022/04/07 2:15 a.m.7 views

CVE-2020-27374

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring...

7.5CVSS7.1AI score0.00783EPSS
Exploits1References3
OSV
OSV
added 2022/04/07 2:15 a.m.6 views

CVE-2020-27376

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Missing Authentication...

8.8CVSS5.8AI score0.00964EPSS
Exploits1References3
CNNVD
CNNVD
added 2022/04/07 12:0 a.m.5 views

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 访问控制错误漏洞

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is vulnerable to an access control error, for which no details are currently available No details of the vulnerability are...

8.8CVSS5.5AI score0.00964EPSS
Exploits1References4
CNNVD
CNNVD
added 2022/04/07 12:0 a.m.4 views

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 安全漏洞

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. A security vulnerability exists in Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1, which stems from vulnerability to replay attacks against BP Monitoring. No detailed...

7.9CVSS5.5AI score0.00783EPSS
Exploits1References4
CNNVD
CNNVD
added 2022/04/07 12:0 a.m.5 views

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 操作系统命令注入漏洞

Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to an operating system command injection vulnerability. The vulnerability stems from a vulnerability to pla...

8.8CVSS5.8AI score0.00972EPSS
Exploits1References4
NVD
NVD
added 2019/07/02 9:15 p.m.20 views

CVE-2017-11578

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the...

5.9CVSS5.8AI score0.02049EPSS
Exploits1References3
Prion
Prion
added 2019/07/02 9:15 p.m.14 views

Design/Logic Flaw

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device ca...

4.8CVSS7AI score0.01559EPSS
Exploits1References3Affected Software1
Prion
Prion
added 2019/07/02 9:15 p.m.20 views

Design/Logic Flaw

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the...

4.3CVSS5.8AI score0.02049EPSS
Exploits1References3Affected Software1
Cvelist
Cvelist
added 2019/07/02 8:44 p.m.27 views

CVE-2017-11579

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device ca...

7AI score0.01559EPSS
Exploits1References3
CVE
CVE
added 2019/07/02 8:44 p.m.158 views

CVE-2017-11579

The CVE-2017-11579 entry concerns Blipcare devices offering an open Wireless network named “Blip” for management. The firmware allows users to connect to this network to submit Wi‑Fi credentials, enabling the device to access the Internet. A nearby attacker can sniff credentials and may connect t...

7.1CVSS7AI score0.01559EPSS
Exploits1References3Affected Software1
CNVD
CNVD
added 2017/06/06 12:0 a.m.2 views

Kang Kang Smart Blood Pressure Monitor Android app has arbitrary user password reset vulnerability

KangKang Smart Blood Pressure Monitor Android app is a blood pressure management tool client that provides users with the convenience of measuring, recording, analyzing, and viewing. KangKang Smart Blood Pressure Monitor Android app has an arbitrary user password reset vulnerability, a remote...

7AI score
Exploits0
Rows per page
Query Builder