15 matches found
EUVD-2020-19885
Malware in sbrugna...
EUVD-2020-19887
Malware in sbrugna...
EUVD-2017-3193
Malware in sbrugna...
EUVD-2017-3194
Malware in sbrugna...
CVE-2020-27374
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring...
CVE-2020-27376
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Missing Authentication...
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 访问控制错误漏洞
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is vulnerable to an access control error, for which no details are currently available No details of the vulnerability are...
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 安全漏洞
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. A security vulnerability exists in Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1, which stems from vulnerability to replay attacks against BP Monitoring. No detailed...
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 操作系统命令注入漏洞
Dr Trust USA iCheck Connect BP Monitor BP Testing 118 is a digital blood pressure monitor and tester from Dr Trust. Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to an operating system command injection vulnerability. The vulnerability stems from a vulnerability to pla...
CVE-2017-11578
It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the...
Design/Logic Flaw
In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device ca...
Design/Logic Flaw
It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the...
CVE-2017-11579
In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device ca...
CVE-2017-11579
The CVE-2017-11579 entry concerns Blipcare devices offering an open Wireless network named “Blip” for management. The firmware allows users to connect to this network to submit Wi‑Fi credentials, enabling the device to access the Internet. A nearby attacker can sniff credentials and may connect t...
Kang Kang Smart Blood Pressure Monitor Android app has arbitrary user password reset vulnerability
KangKang Smart Blood Pressure Monitor Android app is a blood pressure management tool client that provides users with the convenience of measuring, recording, analyzing, and viewing. KangKang Smart Blood Pressure Monitor Android app has an arbitrary user password reset vulnerability, a remote...