40 matches found
Entrust nShield Connect XC 安全漏洞
Entrust nShield Connect XC is a network-connected hardware security module from Entrust USA. A security vulnerability exists in the Entrust nShield Connect XC that stems from the BIOS menu not being password-protected, which could allow an attacker to access the BIOS menu...
EUVD-2020-26543
Malware in sbrugna...
EUVD-2005-4171
Malware in sbrugna...
EUVD-2017-11894
Malware in sbrugna...
EUVD-2023-32664
Malicious code in bioql PyPI...
EUVD-2024-54269
Malicious code in bioql PyPI...
EUVD-2022-43452
Malicious code in bioql PyPI...
CVE-2022-40134
An information leak vulnerability in the SMI Set BIOS Password SMI Handler in some Lenovo models may allow an attacker with local access and elevated privileges to read SMM memory...
Schweitzer Engineering Laboratories多款产品 安全漏洞
Schweitzer Engineering Laboratories SEL-5033 acSELerator RTAC Software and more are products of Schweitzer Engineering Laboratories, Inc. of the U.S.A. Schweitzer Engineering Laboratories SEL-5033 acSELerator RTAC Software is a graphical, easy-to-use tool that helps users quickly and easily...
CVE-2024-56182
A vulnerability has been identified in SIMATIC Field PG M5 All versions, SIMATIC Field PG M6 All versions V26.01.12, SIMATIC IPC BX-21A All versions V31.01.07, SIMATIC IPC BX-32A All versions V29.01.07, SIMATIC IPC BX-39A All versions V29.01.07, SIMATIC IPC BX-59A All versions V32.01.04, SIMATIC...
CVE-2024-56182
A vulnerability has been identified in SIMATIC Field PG M5 All versions, SIMATIC Field PG M6 All versions V26.01.12, SIMATIC IPC BX-21A All versions V31.01.07, SIMATIC IPC BX-32A All versions V29.01.07, SIMATIC IPC BX-39A All versions V29.01.07, SIMATIC IPC BX-59A All versions V32.01.04, SIMATIC...
CVE-2024-56182
A vulnerability has been identified in SIMATIC Field PG M5 All versions, SIMATIC Field PG M6 All versions V26.01.12, SIMATIC IPC BX-21A All versions V31.01.07, SIMATIC IPC BX-32A All versions V29.01.07, SIMATIC IPC BX-39A All versions V29.01.07, SIMATIC IPC BX-59A All versions V32.01.04, SIMATIC...
CVE-2024-56182
A vulnerability has been identified in SIMATIC Field PG M5 All versions, SIMATIC Field PG M6 All versions V26.01.12, SIMATIC IPC BX-21A All versions V31.01.07, SIMATIC IPC BX-32A All versions V29.01.07, SIMATIC IPC BX-39A All versions V29.01.07, SIMATIC IPC BX-59A All versions V32.01.04, SIMATIC...
CVE-2024-56182
A vulnerability has been identified in SIMATIC Field PG M5 All versions, SIMATIC Field PG M6 All versions V26.01.12, SIMATIC IPC BX-21A All versions V31.01.07, SIMATIC IPC BX-32A All versions V29.01.07, SIMATIC IPC BX-39A All versions V29.01.07, SIMATIC IPC BX-59A All versions V32.01.04, SIMATIC...
CVE-2024-56182
CVE-2024-56182 describes a local vulnerability in Siemens SIMATIC/SIEMENS IPC family where EFI variables are insufficiently protected. This could allow an authenticated local attacker to disable the BIOS password by communicating with the flash controller, affecting a wide range of Field PGs, IPC...
Siemens SIMATIC 缓冲区错误漏洞
Siemens SIMATIC is a configuration software from Siemens, Germany. A buffer error vulnerability exists in Siemens SIMATIC that stems from an inadequate protection mechanism for EFI variables, which could allow an authenticated attacker to disable the BIOS password...
CVE-2023-29061
There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authentication...
Authentication flaw
There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to access the BIOS configuration and modify the drive boot order and BIOS pre-boot authentication...
CVE-2023-29061
BD FACSChorus is affected by CVE-2023-29061 due to missing BIOS password on the workstation. In BD FACSChorus v5.0, v5.1, v3.0, and v3.1, a threat actor with physical access can access BIOS settings and modify boot order and pre-boot authentication. CVSS v3.1 base score 5.2 (AV:P, AC:L, PR:N, UI:...
BD FACSChorus Security Breach
The BD FACSChorus is a multichannel flow cytometry system from BD Medical BD. A security vulnerability exists in the BD FACSChorus that stems from the absence of a BIOS password on the workstation...