CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

2.4CVSS6.3AI score0.00058EPSS
Exploits1References1
CNVD
CNVD
added 2019/08/13 12:0 a.m.2 views

BC Vault Information Disclosure Vulnerability

BC Vault is an e-wallet device for storing cryptocurrencies. An information disclosure vulnerability exists in BC Vault. The vulnerability stems from errors such as configuration during operation of a networked system or product. An unauthorized attacker could exploit the vulnerability to obtain...

2.4CVSS6.2AI score0.00058EPSS
Exploits1References1
NVD
NVD
added 2019/08/12 11:15 p.m.9 views

CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

2.4CVSS3.3AI score0.00058EPSS
Exploits1References1
Prion
Prion
added 2019/08/12 11:15 p.m.9 views

Code injection

DISPUTED On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might...

2.1CVSS3.6AI score0.00058EPSS
Exploits1References1
Cvelist
Cvelist
added 2019/08/12 10:31 p.m.12 views

CVE-2019-14359

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able ...

3.3AI score0.00058EPSS
Exploits1References1
CVE
CVE
added 2019/08/12 10:31 p.m.61 views

CVE-2019-14359

CVE-2019-14359 describes a side-channel on BC Vault devices where the power usage per row of the SSD1309 OLED display leaks information about the number of illuminated pixels. The practical impact is limited: an attacker would need control over the device’s USB connection to measure power while s...

2.4CVSS3.5AI score0.00058EPSS
Exploits1References1Affected Software1
Positive Technologies
Positive Technologies
added 2019/08/12 12:0 a.m.2 views

PT-2019-13638 · Bc Vault · Bc Vault

Name of the Vulnerable Software and Affected Versions: BC Vault affected versions not specified Description: A side channel was discovered related to the row-based SSD1309 OLED display on BC Vault devices. The power consumption during each display cycle varies based on the number of illuminated...

2.4CVSS6.7AI score0.00058EPSS
Exploits1References2
Rows per page
Query Builder