468 matches found
CVE-2018-7277
An issue was discovered on RLE Wi-MGR/FDS-Wi 6.2 devices. Persistent XSS exists in the web server. Remote attackers can inject malicious JavaScript code using the device's BACnet implementation. This is similar to a Cross Protocol Injection with SNMP...
CVE-2018-7276
An issue was discovered on Lutron Quantum BACnet Integration 2.0 firmware 3.2.243 devices. Remote attackers can obtain potentially sensitive information via a /DbXmlInfo.xml request, as demonstrated by the Latitude/Longitude of the device...
ABB Cylon BACnet MS/TP Kernel Module (mstp.ko) Out-of-Bounds Write in SendFrame()
Summary ASPECT is an award-winning scalable building energy management and control solution designed to allow users seamless access to their building data through standard building protocols including smart devices. BACnet Smart Building Controllers. ABB's BACnet portfolio features a series of...
📄 ABB Cylon FLXeon 9.3.5 variant.js Information Disclosure
The ABB Cylon FLXeon BACnet controller's /api/variant endpoint exposes sensitive system information, including the internal IP address, MAC address, device model, and build type, without requiring authentication. The get function gathers network interface data using the os.networkInterfaces API a...
ABB Cylon FLXeon 9.3.5 (variant.js) Unauthenticated System Information Disclosure
Summary BACnet® Smart Building Controllers. ABB's BACnet portfolio features a series of BACnet® IP and BACnet MS/TP field controllers for ASPECT® and INTEGRA™ building management solutions. ABB BACnet controllers are designed for intelligent control of HVAC equipment such as central plant, boiler...
📄 ABB Cylon FLXeon 9.3.5 uukl.js Predictable Salt / Weak Hashing Algorithm
The ABB Cylon FLXeon BACnet controller's /api/uukl.js module implements password verification and update mechanisms using the insecure MD5 hash function alongside weak salt generation via Math.random. This constitutes a cryptographic vulnerability where password hashes are susceptible to collisio...
ABB Cylon FLXeon 9.3.5 (siteGuide.js) Authenticated Directory Traversal
Summary BACnet® Smart Building Controllers. ABB's BACnet portfolio features a series of BACnet® IP and BACnet MS/TP field controllers for ASPECT® and INTEGRA™ building management solutions. ABB BACnet controllers are designed for intelligent control of HVAC equipment such as central plant, boiler...
ABB Cylon FLXeon 9.3.5 (siteGuide.js) Authenticated Root Remote Code Execution
Summary BACnet® Smart Building Controllers. ABB's BACnet portfolio features a series of BACnet® IP and BACnet MS/TP field controllers for ASPECT® and INTEGRA™ building management solutions. ABB BACnet controllers are designed for intelligent control of HVAC equipment such as central plant, boiler...
📄 ABB Cylon FLXeon 9.3.5 siteGuide.js Authenticated Root Remote Code Execution
The ABB Cylon FLXeon BACnet controller is vulnerable to authenticated remote root code execution via the /api/siteGuide endpoint. An attacker with valid credentials can inject arbitrary system commands by manipulating the filename and/or originalname parameters. The issue arises due to improper...
ABB Cylon FLXeon 9.3.5 (capture.js) Authenticated File Disclosure/Delete
Summary BACnet® Smart Building Controllers. ABB's BACnet portfolio features a series of BACnet® IP and BACnet MS/TP field controllers for ASPECT® and INTEGRA™ building management solutions. ABB BACnet controllers are designed for intelligent control of HVAC equipment such as central plant, boiler...
ABB Cylon FLXeon 9.3.5 (bbmdList.js) Authenticated Config Poisoning
Summary BACnet® Smart Building Controllers. ABB's BACnet portfolio features a series of BACnet® IP and BACnet MS/TP field controllers for ASPECT® and INTEGRA™ building management solutions. ABB BACnet controllers are designed for intelligent control of HVAC equipment such as central plant, boiler...
CVE-2025-24510
A vulnerability has been identified in MS/TP Point Pickup Module All versions. Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in various products such as Apogee, BacNet ATEC, Desigo CC, Intralog, OZW, Polarion, RUGGEDCOM, SICAM, SIMATIC, SIPROTEC, SIRIUS, Teamcenter and Versicharge The vulnerabilities potentially enable a malicious person to launch attacks that could result in the...
CVE-2025-40556
A vulnerability has been identified in BACnet ATEC 550-440 All versions, BACnet ATEC 550-441 All versions, BACnet ATEC 550-445 All versions, BACnet ATEC 550-446 All versions. Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the sa...
CVE-2025-40555
A vulnerability has been identified in APOGEE PXC+TALON TC Series BACnet All versions. Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially...
CVE-2025-40556
The CVE-2025-40556 vulnerability affects Siemens BACnet ATEC devices (550-440, 550-441, 550-445, 550-446). Affected systems improperly handle specific BACnet MSTP messages, enabling an attacker on the same BACnet network to send crafted MSTP traffic that causes a denial of service, recoverable on...
CVE-2025-40556
A vulnerability has been identified in BACnet ATEC 550-440 All versions, BACnet ATEC 550-441 All versions, BACnet ATEC 550-445 All versions, BACnet ATEC 550-446 All versions. Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the sa...
CVE-2025-40556
A vulnerability has been identified in BACnet ATEC 550-440 All versions, BACnet ATEC 550-441 All versions, BACnet ATEC 550-445 All versions, BACnet ATEC 550-446 All versions. Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the sa...
CVE-2025-40555
A vulnerability has been identified in APOGEE PXC+TALON TC Series BACnet All versions. Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially...
CVE-2025-40555
A vulnerability has been identified in APOGEE PXC+TALON TC Series BACnet All versions. Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially...