Schneider Electric Modicon M580 UMAS function code 0x28 denial-of-service vulnerability
Summary An exploitable denial-of-service vulnerability exists in the UMAS function code 0x28 functionality of the Schneider Electric Modicon M580 Programmable Automation Controller, firmware version SV2.70. A specially crafted UMAS command can cause the device to enter a non-recoverable fault...
Schneider Electric Modicon M580 UMAS Read Memory Block Out Of Bounds Information Disclosure Vulnerability
Summary An exploitable information disclosure vulnerability exists in the UMAS memory block read functionality of the Schneider Electric Modicon M580 Programmable Automation Controller. A specially crafted UMAS request can cause an out of bounds read, resulting in disclosure of sensitive...
Schweitzer Engineering Laboratories Real-Time Automation Controller (RTAC) PLC Detection
Binary data 755324.prm...
Rockwell Automation Micro820 2080-LC20-32QWB Programmable Logic Controller
Binary data 753133.prm...
Schweitzer Engineering Laboratories DPAC Discrete Programmable Automation Controller PLC Detection
Binary data 755335.prm...
Schweitzer Engineering Laboratories Real-Time Automation Controller (RTAC) PLC Detection
Binary data 755327.prm...
Schweitzer Engineering Laboratories Real-Time Automation Controller (RTAC) PLC Detection
Binary data 755326.prm...
Schweitzer Engineering Laboratories Pump Automation Controller PLC Detection
Binary data 755334.prm...
Schweitzer Engineering Laboratories Real-Time Automation Controller (RTAC) PLC Detection
Binary data 755325.prm...
CVE-2016-9343
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 excluding all firmware versions prior to FRN 16.00, which are not affected. By sending malformed common industrial protocol CIP packet, an attacker may be able to overflow a...
CVE-2016-9343
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 excluding all firmware versions prior to FRN 16.00, which are not affected. By sending malformed common industrial protocol CIP packet, an attacker may be able to overflow a...
CVE-2016-9343
CVE-2016-9343 affects Rockwell Automation Logix5000 controllers (FRN 16.00–21.00; earlier FRN 16.00+ excluded) via malformed CIP packets that overflow a stack-based buffer, enabling potential code execution or a nonrecoverable fault causing denial of service. The vulnerability is a stack-based bu...
INSTEON Hub 2242-222 - Lack of Web and API Authentication
INSTEON Hub 2242-222 - Lack of Web and API Authentication Trustwave SpiderLabs Security Advisory TWSL2013-023: Lack of Web and API Authentication Vulnerability in INSTEON Hub Published: 8/01/13 Version: 1.0 Vendor: INSTEON http://www.INSTEON.com/ Product: Hub Version affected: 2242-222 model...