15167 matches found
CVE-2024-13813
Insufficient permissions in Ivanti Secure Access Client before version 22.8R1 allows a local authenticated attacker to delete arbitrary files...
CVE-2024-13843
Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-27781
An improper neutralization of input during web page generation 'cross-site scripting' vulnerability in Fortinet FortiSandbox 4.4.0 through 4.4.4, FortiSandbox 4.2.1 through 4.2.6, FortiSandbox 4.0.0 through 4.0.4, FortiSandbox 3.2 all versions, FortiSandbox 3.1 all versions, FortiSandbox 3.0 all...
CVE-2024-27780
Multiple Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerabilities CWE-79 in FortiSIEM 7.1 all versions, 7.0 all versions, 6.7 all versions incident page may allow an authenticated attacker to perform a cross-site scripting attack via crafted HTTP requests...
CVE-2024-27780
Fortinet FortiSIEM is affected by a cross-site scripting vulnerability (CWE-79) in the incident page due to improper neutralization of input. Affected products: FortiSIEM versions 6.7 through 7.1. An authenticated attacker could trigger the XSS via crafted HTTP requests. There is no public detail...
CVE-2024-13813
CVE-2024-13813 concerns Ivanti Secure Access Client. The vulnerability is due to insufficient permissions in ISAC prior to version 22.8R1, allowing a local authenticated attacker to delete arbitrary files. Affected software: Ivanti Secure Access Client (ISAC) before 22.8R1. Impact: local file del...
CVE-2024-13813
Insufficient permissions in Ivanti Secure Access Client before version 22.8R1 allows a local authenticated attacker to delete arbitrary files...
CVE-2024-13813
Insufficient permissions in Ivanti Secure Access Client before version 22.8R1 allows a local authenticated attacker to delete arbitrary files...
CVE-2024-13843
CVE-2024-13843 affects Ivanti Connect Secure and Ivanti Policy Secure prior to versions 22.7R2.6 and 22.7R1.3, respectively. The root issue is the cleartext storage of information, allowing a local authenticated attacker with admin privileges to read sensitive data. Impact is limited to confident...
CVE-2024-13843
Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-13843
Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-13842
CVE-2024-13842 details: Ivanti Connect Secure prior to 22.7R2.3 (and Ivanti Policy Secure prior to 22.7R1.3) contains a hardcoded key that enables a local, authenticated attacker with admin privileges to read sensitive data. The vulnerability is an information disclosure issue within the admin po...
CVE-2024-13842
A hardcoded key in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data...
CVE-2024-12058
External control of a file name in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a remote authenticated attacker with admin privileges to read arbitrary files...
CVE-2024-12058
External control of a file name in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a remote authenticated attacker with admin privileges to read arbitrary files...
CVE-2025-23403
Summary (CVE-2025-23403) : Siemens SIMATIC IPC DiagBase and DiagMonitor (All versions) have a vulnerability where user permissions for a registry key are not properly restricted. An authenticated attacker could load vulnerable drivers, leading to privilege escalation or bypassing endpoint protect...
CVE-2025-23403
A vulnerability has been identified in SIMATIC IPC DiagBase All versions, SIMATIC IPC DiagMonitor All versions. The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to...
CVE-2025-23403
A vulnerability has been identified in SIMATIC IPC DiagBase All versions, SIMATIC IPC DiagMonitor All versions. The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to...
CVE-2025-26411
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web...
CVE-2025-26411 Authenticated Arbitrary Python File Upload via Plugin Manager
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web...