17 matches found
EUVD-2025-19244
Malicious code in bioql PyPI...
EUVD-2022-29197
Malicious code in bioql PyPI...
CISA Releases Three Industrial Control Systems Advisories
CISA released three Industrial Control Systems ICS advisories on August 21, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-233-01 Mitsubishi Electric Corporation MELSEC iQ-F Series CPU Module ICSA-25-177-01...
CVE-2025-3699
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all...
CVE-2025-3699
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all...
CVE-2025-3699
The CVE-2025-3699 issue affects Mitsubishi Electric G-50 family and related controllers (G-50, G-50-W, G-50A, GB-50/50A, GB-24A, G-150AD, AG-150A-A/J, GB-50AD/ADA-J, EB-50GU-A/J, AE/EW/TE-200A/50E, TW-50A, CMS-RMD-J) with versions listed as 3.37 and earlier (and 9.12 and earlier for GB-24A). A re...
PT-2025-27019
Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Corporation G-50 versions 3.37 and prior Mitsubishi Electric Corporation G-50-W versions 3.37 and prior Mitsubishi Electric Corporation G-50A versions 3.37 and prior Mitsubishi Electric Corporation GB-50 versions 3.37 and...
CVE-2022-24296
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
CVE-2021-20593
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and...
Mitsubishi Electric Air Conditioning Systems
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: Air Conditioning Systems Vulnerabilities: Use of a Broken or Risky Cryptographic Algorithm, Exposure of Sensitive Information to an Unauthorized Actor, Channel Accessible by Non-Endpoint 2...
CVE-2022-24296
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
CVE-2022-24296
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
Design/Logic Flaw
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
CVE-2022-24296
Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditionin...
CVE-2021-20595
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.2...
Mitsubishi Electric Air Conditioning System
1. EXECUTIVE SUMMARY CVSS v3 7.1 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: Multiple Air Conditioning Systems Vulnerability: Incorrect Implementation of Authentication Algorithm 2. RISK EVALUATION An attacker could exploit this vulnerability by impersonating...
Mitsubishi Electric Air Conditioning Systems 代码问题漏洞
Mitsubishi Electric Air Conditioning Systems is an air conditioning system from Mitsubishi Electric, a Japanese company. Mitsubishi Electric Air Conditioning Systems has a code issue vulnerability that stems from a flaw in the product's authorization mechanism...