5515 matches found
Linux Distros Unpatched Vulnerability : CVE-2024-29477
The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Lack of sanitization during Installation Process in Dolibarr ERP CRM up to version 19.0.0 allows an attacker with adjacent access to the network to execute...
PT-2025-37065
Name of the Vulnerable Software and Affected Versions: Cisco IOS XR Software affected versions not specified Description: A vulnerability in the Address Resolution Protocol ARP implementation of Cisco IOS XR Software could allow an unauthenticated, adjacent attacker to trigger a broadcast storm,...
CVE-2025-59042
CVE-2025-59042 is a PyInstaller-related issue. In PyInstaller builds older than 6.0.0, the bootstrap process appends a special entry to sys.path and may load an optional bytecode-decryption module, enabling an unprivileged attacker to execute arbitrary Python code if they can place a file/dir nex...
CVE-2025-32330: Initialization of a Resource with an Insecure Default
In generateRandomPassword of LocalBluetoothLeBroadcast.java, there is a possible way to intercept the Auracast audio stream due to an insecure default value. This could lead to remote proximal/adjacent information disclosure with no additional execution privileges needed. User interaction is not...
CVE-2025-48539: Use After Free
In SendPacketToPeer of aclarbiter.cc, there is a possible out of bounds read due to a use after free. This could lead to remote proximal/adjacent code execution with no additional execution privileges needed. User interaction is not needed for exploitation...
CVE-2025-20241 Cisco Nexus 3000 and 9000 Series Switches IS-IS Protocol <TBD> Denial of Service Vulnerability
A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...
CVE-2025-20241
CVE-2025-20241 affects Cisco NX-OS Software on Nexus 3000 and Nexus 9000 Series switches (standalone NX-OS mode). The issue is caused by insufficient input validation when parsing ingress IS-IS packets, allowing an unauthenticated, Layer-2-adjacent attacker to trigger an IS-IS process restart and...
Cisco Nexus 3000 and 9000 Series Switches Intermediate System-to-Intermediate System Denial of Service Vulnerability
A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...
PT-2025-34887
Name of the Vulnerable Software and Affected Versions Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches Description A vulnerability exists in the Intermediate System-to-Intermediate System IS-IS feature. An unauthenticated, adjacent attacker could...
CVE-2025-20241: Compiler Optimization Removal or Modification of Security-critical Code
A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...
CVE-2025-22412: Use After Free
In multiple functions of sdpserver.cc, there is a possible use after free due to a logic error in the code. This could lead to remote proximal/adjacent code execution with no additional execution privileges needed. User interaction is not needed for exploitation...
CVE-2025-0092: Insufficient Verification of Data Authenticity
In handleBondStateChanged of AdapterService.java, there is a possible permission bypass due to misleading or insufficient UI. This could lead to remote proximal/adjacent information disclosure with no additional execution privileges needed. User interaction is needed for exploitation...
CVE-2025-27214
A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro Version 1.5.18 and earlier Mitigation: Update Uni...
CVE-2025-48978
An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...
CVE-2025-27214
The UniFi Connect EV Station Pro (versions 1.5.18 and earlier ) is vulnerable to a Missing Authentication for Critical Function (CWE-306) security flaw. A malicious actor with physical or adjacent access can exploit this lack of authentication to perform an unauthorized factory reset . To remedia...
CVE-2025-48978
The EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) is vulnerable to Command Injection due to Improper Input Validation . A malicious actor with access to the adjacent network can exploit this flaw to execute arbitrary commands on the device. To remediate this vulnerability, users should update t...
CVE-2025-27214
A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro Version 1.5.18 and earlier Mitigation: Update Uni...
CVE-2025-48978
An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...
Linux Distros Unpatched Vulnerability : CVE-2021-0175
The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Improper Validation of Specified Index, Position, or Offset in Input in firmware for some IntelR PROSet/Wireless Wi-Fi in multiple operating systems and some...
CVE-2025-48978: Improper Neutralization of Special Elements used in a Command
An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...