Lucene search
+L

5515 matches found

Tenable Nessus
Tenable Nessus
•added 2025/09/10 12:00 a.m.•5 views

Linux Distros Unpatched Vulnerability : CVE-2024-29477

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Lack of sanitization during Installation Process in Dolibarr ERP CRM up to version 19.0.0 allows an attacker with adjacent access to the network to execute...

8.8CVSS8.3AI score0.00815EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2025/09/10 12:00 a.m.•19 views

PT-2025-37065

Name of the Vulnerable Software and Affected Versions: Cisco IOS XR Software affected versions not specified Description: A vulnerability in the Address Resolution Protocol ARP implementation of Cisco IOS XR Software could allow an unauthenticated, adjacent attacker to trigger a broadcast storm,...

7.4CVSS6.1AI score0.0061EPSS
SaveExploits0References9
CVE
CVE
•added 2025/09/09 10:28 p.m.•58 views

CVE-2025-59042

CVE-2025-59042 is a PyInstaller-related issue. In PyInstaller builds older than 6.0.0, the bootstrap process appends a special entry to sys.path and may load an optional bytecode-decryption module, enabling an unprivileged attacker to execute arbitrary Python code if they can place a file/dir nex...

7CVSS7.2AI score0.00126EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/09/04 12:00 a.m.•7 views

CVE-2025-32330: Initialization of a Resource with an Insecure Default

In generateRandomPassword of LocalBluetoothLeBroadcast.java, there is a possible way to intercept the Auracast audio stream due to an insecure default value. This could lead to remote proximal/adjacent information disclosure with no additional execution privileges needed. User interaction is not...

5.7CVSS5.9AI score0.00128EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/09/04 12:00 a.m.•4 views

CVE-2025-48539: Use After Free

In SendPacketToPeer of aclarbiter.cc, there is a possible out of bounds read due to a use after free. This could lead to remote proximal/adjacent code execution with no additional execution privileges needed. User interaction is not needed for exploitation...

8CVSS7.8AI score0.00433EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/08/27 4:23 p.m.•26 views

CVE-2025-20241 Cisco Nexus 3000 and 9000 Series Switches IS-IS Protocol <TBD> Denial of Service Vulnerability

A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...

7.4CVSS0.00278EPSS
SaveExploits0References1
CVE
CVE
•added 2025/08/27 4:23 p.m.•70 views

CVE-2025-20241

CVE-2025-20241 affects Cisco NX-OS Software on Nexus 3000 and Nexus 9000 Series switches (standalone NX-OS mode). The issue is caused by insufficient input validation when parsing ingress IS-IS packets, allowing an unauthenticated, Layer-2-adjacent attacker to trigger an IS-IS process restart and...

7.4CVSS6.7AI score0.00278EPSS
SaveExploits0References1
Cisco
Cisco
•added 2025/08/27 4:00 p.m.•19 views

Cisco Nexus 3000 and 9000 Series Switches Intermediate System-to-Intermediate System Denial of Service Vulnerability

A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...

7.4CVSS7.2AI score0.00278EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/08/27 12:00 a.m.•19 views

PT-2025-34887

Name of the Vulnerable Software and Affected Versions Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches Description A vulnerability exists in the Intermediate System-to-Intermediate System IS-IS feature. An unauthenticated, adjacent attacker could...

7.4CVSS6.6AI score0.00278EPSS
SaveExploits0References13
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/08/27 12:00 a.m.•3 views

CVE-2025-20241: Compiler Optimization Removal or Modification of Security-critical Code

A vulnerability in the Intermediate System-to-Intermediate System IS-IS feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an unauthenticated, adjacent attacker to cause the IS-IS process to unexpectedly...

7.4CVSS5.8AI score0.00278EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/08/26 12:00 a.m.•3 views

CVE-2025-22412: Use After Free

In multiple functions of sdpserver.cc, there is a possible use after free due to a logic error in the code. This could lead to remote proximal/adjacent code execution with no additional execution privileges needed. User interaction is not needed for exploitation...

8.8CVSS6.5AI score0.00174EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/08/26 12:00 a.m.•5 views

CVE-2025-0092: Insufficient Verification of Data Authenticity

In handleBondStateChanged of AdapterService.java, there is a possible permission bypass due to misleading or insufficient UI. This could lead to remote proximal/adjacent information disclosure with no additional execution privileges needed. User interaction is needed for exploitation...

6.5CVSS5.9AI score0.00152EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/08/23 12:23 a.m.•16 views

CVE-2025-27214

A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro Version 1.5.18 and earlier Mitigation: Update Uni...

9.8CVSS7AI score0.00397EPSS
SaveExploits0References1
NVD
NVD
•added 2025/08/21 1:15 a.m.•16 views

CVE-2025-48978

An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...

7.5CVSS0.00669EPSS
SaveExploits0References1
CVE
CVE
•added 2025/08/21 12:01 a.m.•48 views

CVE-2025-27214

The UniFi Connect EV Station Pro (versions 1.5.18 and earlier ) is vulnerable to a Missing Authentication for Critical Function (CWE-306) security flaw. A malicious actor with physical or adjacent access can exploit this lack of authentication to perform an unauthorized factory reset . To remedia...

9.8CVSS6.9AI score0.00397EPSS
SaveExploits0References1
CVE
CVE
•added 2025/08/21 12:01 a.m.•55 views

CVE-2025-48978

The EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) is vulnerable to Command Injection due to Improper Input Validation . A malicious actor with access to the adjacent network can exploit this flaw to execute arbitrary commands on the device. To remediate this vulnerability, users should update t...

7.5CVSS7.5AI score0.00669EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/08/21 12:01 a.m.•11 views

CVE-2025-27214

A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro Version 1.5.18 and earlier Mitigation: Update Uni...

6.9AI score0.00397EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/08/21 12:01 a.m.•25 views

CVE-2025-48978

An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...

0.00669EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2025/08/21 12:00 a.m.•10 views

Linux Distros Unpatched Vulnerability : CVE-2021-0175

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Improper Validation of Specified Index, Position, or Offset in Input in firmware for some IntelR PROSet/Wireless Wi-Fi in multiple operating systems and some...

6.5CVSS5.9AI score0.00515EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/08/21 12:00 a.m.•2 views

CVE-2025-48978: Improper Neutralization of Special Elements used in a Command

An Improper Input Validation in EdgeMAX EdgeSwitch Version 1.11.0 and earlier could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch Version 1.11.0 and earlier Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11...

7.5CVSS5.9AI score0.00669EPSS
SaveExploits0References1
Rows per page
Query Builder