702 matches found
CVE-2026-21139
Improper access control in Samsung Continuity Service for windows prior to version 4.6.1217.0 allows adjacent attackers to manipulate the connected mobile device...
PT-2026-110467
Improper access control in Samsung Continuity Service for windows prior to version 4.6.1217.0 allows adjacent attackers to manipulate the connected mobile device...
PT-2026-110462
Improper authentication in Samsung Flow prior to version 4.9.22.4 allows adjacent attackers to access sensitive information...
CVE-2026-21139: Undefined Security Weakness
Improper access control in Samsung Continuity Service for windows prior to version 4.6.1217.0 allows adjacent attackers to manipulate the connected mobile device...
CVE-2026-21083
Improper input validation in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to access sensitive data...
CVE-2026-21083
Improper input validation in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to access sensitive data...
EUVD-2026-55108
Improper input validation in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to access sensitive data...
CVE-2026-21083
CVE-2026-21083 affects Samsung Smart Switch software with improper input validation in versions before 3.7.72.6, enabling adjacent attackers to access sensitive data (confidentiality impact high). The description indicates the vulnerability is fixed in 3.7.72.6 or later; update to that version or...
CVE-2026-21080
Cleartext storage of sensitive information in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to access sensitive data...
CVE-2026-21080
The CVE-2026-21080 affects Smart Switch prior to version 3.7.72.6. It stems from cleartext storage of sensitive information, allowing adjacent attackers to access data. Mitigation: upgrade to 3.7.72.6 or later (as described in the provided references).
CVE-2026-21079
Missing encryption of sensitive data in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to intercept transmitted data...
EUVD-2026-55104
Missing encryption of sensitive data in Smart Switch prior to version 3.7.72.6 allows adjacent attackers to intercept transmitted data...
CVE-2026-21079
CVE-2026-21079 concerns Samsung Smart Switch prior to version 3.7.72.6, where missing encryption of sensitive data allows adjacent attackers to intercept transmitted data. The affected component is the Smart Switch data transmission flow; the root cause is lack of encryption for sensitive data in...
CVE-2026-21078
Insufficient verification of data authenticity in Smart Switch trouble scanning mode prior to version 3.7.72.6 allows adjacent attackers to spoof device identity...
PT-2026-65860
Name of the Vulnerable Software and Affected Versions Devolutions Password Manager versions prior to 2026.2.1.1 Description Improper certificate validation in the Devolutions Server connection handling allows an adjacent-network attacker to intercept and modify sensitive information by using a...
CVE-2026-66005
CVE-2026-66005 affects Jan up to version 0.8.4. The local API server has a CORS misconfiguration that replaces user-configured trusted hosts with a wildcard, reflecting arbitrary origins with credentials. This enables network-adjacent attackers to bypass trusted host restrictions and reach the un...
PT-2026-64318
Name of the Vulnerable Software and Affected Versions Jan versions prior to 0.8.4 Description A CORS Cross-Origin Resource Sharing misconfiguration in the local API server allows network-adjacent attackers to bypass trusted host restrictions. This occurs because the server replaces user-configure...
CVE-2026-15683
Lorex 2K Indoor Wi-Fi Security Camera Device Management Server Improper Certificate Validation Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Lorex 2K Indoor Wi-Fi Security Cameras. User interaction is not required to...
EUVD-2024-55607
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages during the discovery process. Attackers with access to the hospital network ca...
CVE-2026-44064
An out-of-bounds read in ASP session ID handling in Netatalk 1.3 through 4.4.2 allows an adjacent network attacker to obtain limited information or cause a denial of service via a crafted ASP request...