860 matches found
EUVD-2026-68610
The affected Ebyte product's vendor configuration utility permits access to administrative functions without verifying the operator's identity under certain credential conditions. An unauthenticated attacker on the adjacent network could modify critical settings or change access credentials,...
CVE-2026-73819
Ebyte NE2-D11 (and NA111-M ) vendor configuration utility contains a weak authentication flaw: under certain credential conditions, administrative functions are accessible without verifying the operator's identity. An unauthenticated attacker on the adjacent network could modify critical settings...
EUVD-2026-68609
The affected Ebyte product exports administrative credentials and other sensitive configuration information without adequate protection. An unauthenticated attacker on the adjacent network who can obtain an exported configuration file could recover valid credentials and use them to access the...
CVE-2026-77975
Ebyte NE2-D11 (also affecting the NA111-M model) contains a cleartext storage of sensitive information vulnerability. The device exports administrative credentials and other sensitive configuration data without adequate protection. An unauthenticated attacker on the adjacent network who obtains a...
EUVD-2026-66405
A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device...
EUVD-2026-67295
Ebyte gateway product's vendor configuration utility does not require authentication before allowing certain disruptive administrative actions when default credentials remain configured. An unauthenticated attacker on the adjacent network could reboot the device or restore factory settings,...
CVE-2026-77977
Ebyte gateway product's vendor configuration utility does not require authentication before allowing certain disruptive administrative actions when default credentials remain configured. An unauthenticated attacker on the adjacent network could reboot the device or restore factory settings,...
CVE-2026-77977
Ebyte NE2-D11 is an industrial gateway whose vendor configuration utility lacks authentication before permitting disruptive administrative actions (reboot or factory reset) when default credentials remain configured. An unauthenticated attacker on the adjacent network can trigger these actions, c...
CVE-2026-77977 Ebyte NA111-M Missing Authentication for Critical Function
Ebyte gateway product's vendor configuration utility does not require authentication before allowing certain disruptive administrative actions when default credentials remain configured. An unauthenticated attacker on the adjacent network could reboot the device or restore factory settings,...
CVE-2026-76784
Multiple TP-Link Kasa smart home devices contain insufficient cryptographic protections in the local device communication protocol. An adjacent network attacker may intercept, replay or forge locally exchanged control messages, potentially resulting in unauthorized device control. Successful...
CVE-2026-76784 Insufficient Cryptographic Protections in Local Device Communication Protocol on Multiple TP-Link Kasa Smart Home Devices
Multiple TP-Link Kasa smart home devices contain insufficient cryptographic protections in the local device communication protocol. An adjacent network attacker may intercept, replay or forge locally exchanged control messages, potentially resulting in unauthorized device control. Successful...
EUVD-2026-66641
Multiple TP-Link Kasa smart home devices contain insufficient cryptographic protections in the local device communication protocol. An adjacent network attacker may intercept, replay or forge locally exchanged control messages, potentially resulting in unauthorized device control. Successful...
CVE-2026-77532
A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device...
CVE-2026-77532
A malicious actor with access to an adjacent network could exploit a Buffer Overflow vulnerability found in a DHCPv6-enabled EdgeMAX EdgeSwitch to initiate a Remote Code Execution on such device...
CVE-2026-77532
A Buffer Overflow vulnerability in the DHCPv6 functionality of Ubiquiti EdgeMAX EdgeSwitch devices allows an unauthenticated actor on an adjacent network to achieve Remote Code Execution . The CNA-assigned CVSS 3.1 score is 9.6 (CRITICAL) , with low attack complexity, no required privileges or us...
PT-2026-82235
Name of the Vulnerable Software and Affected Versions TP-Link Kasa affected versions not specified Description Multiple smart home devices have insufficient cryptographic protections in the local device communication protocol. An attacker on the same network can intercept, replay, or forge locall...
CVE-2026-78915
Race condition in Enterprise in Google Chrome on on Windows prior to 152.0.7977.65 allowed an adjacent attacker to potentially execute arbitrary code outside the sandbox via crafted network traffic. Chromium security severity: Low...
CVE-2026-57909
A path traversal vulnerability in WatchGuard Agent allows a remote, unauthenticated attacker on an adjacent network to execute arbitrary code on an affected system...
CVE-2026-57909
CVE-2026-57909 is a path traversal vulnerability in WatchGuard Agent that allows a remote, unauthenticated attacker on an adjacent network to execute arbitrary code on an affected system. No user interaction or special privileges are required. The CVSS 4.0 base score is 9.4 (CRITICAL) , reflectin...
CVE-2026-57909 WatchGuard Agent path traversal allows unauthenticated remote code execution
A path traversal vulnerability in WatchGuard Agent allows a remote, unauthenticated attacker on an adjacent network to execute arbitrary code on an affected system...