Lucene search
+L

49 matches found

ICS
ICS
added 2023/01/26 12:0 a.m.35 views

Mitsubishi Electric MELFA SD/SQ series and F-series Robot Controllers

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Corporation Equipment: MELFA SD/SQ series and F-series Robot Controllers Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow...

7.5CVSS8.3AI score0.01144EPSS
Exploits0References4
NVD
NVD
added 2023/01/17 10:15 a.m.33 views

CVE-2023-22357

Active debug code exists in OMRON CP1L-EL20DR-D all versions, which may lead to a command that is not specified in FINS protocol being executed without authentication. A remote unauthenticated attacker may read/write in arbitrary area of the device memory, which may lead to overwriting the...

9.8CVSS9.8AI score0.0117EPSS
Exploits0References1
Prion
Prion
added 2023/01/17 10:15 a.m.24 views

Design/Logic Flaw

Active debug code exists in OMRON CP1L-EL20DR-D all versions, which may lead to a command that is not specified in FINS protocol being executed without authentication. A remote unauthenticated attacker may read/write in arbitrary area of the device memory, which may lead to overwriting the...

7.5CVSS9.7AI score0.0117EPSS
Exploits0References1
ICS
ICS
added 2022/11/10 12:0 a.m.39 views

Omron NJ/NX-series Machine Automation Controllers

1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely, public exploits are available Vendor: Omron Equipment: NJ/NX-series Machine Automation Controllers Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain...

8.3CVSS7.8AI score0.01146EPSS
Exploits0References5
ICS
ICS
added 2022/09/01 6:0 a.m.50 views

Contec Health CMS8000 Patient Monitor (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Low attack complexity Vendor: Contec Health Equipment: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor Vulnerabilities: Improper Access Control, Uncontrolled Resource Consumption, Use of Hard-Coded Credentials, Active Debug Code 2. RISK EVALUATION...

7.5CVSS7AI score0.00797EPSS
Exploits0References10
OSV
OSV
added 2021/05/20 2:15 p.m.6 views

CVE-2021-28112

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker...

8.8CVSS6.4AI score0.01878EPSS
Exploits0References2
Prion
Prion
added 2021/05/20 2:15 p.m.18 views

Remote code execution

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker...

6.5CVSS8.9AI score0.01878EPSS
Exploits0References2Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/05/20 2:15 p.m.5 views

CVE-2021-28112

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker...

8.8CVSS8.8AI score0.01878EPSS
Exploits0References3
Cvelist
Cvelist
added 2021/05/20 1:32 p.m.18 views

CVE-2021-28112

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker...

9.2AI score0.01878EPSS
Exploits0References2
Rows per page
Query Builder