Lucene search
+L

11 matches found

EUVD
EUVD
added 2026/09/17 8:26 a.m.5 views

EUVD-2026-81402

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications,...

9.3CVSS0.00091EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/17 8:21 a.m.8 views

CVE-2026-50609 Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, thi...

9.3CVSS0.00091EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/17 8:21 a.m.5 views

EUVD-2026-81401

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, thi...

9.3CVSS0.00091EPSS
SaveExploits0References1
NVD
NVD
added 2026/09/17 8:17 a.m.5 views

CVE-2026-50606

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key ...

5.1CVSS0.00072EPSS
SaveExploits0References1
NVD
NVD
added 2026/09/17 8:17 a.m.5 views

CVE-2026-50607

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access...

6.9CVSS0.00253EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/17 8:15 a.m.6 views

EUVD-2026-81399

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The WebSocket handshake process does not properly require authentication before allowing connections to the service. Under certain circumstances, unauthorized access to service...

5.1CVSS0.00142EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/17 8:05 a.m.10 views

CVE-2026-50607 WebSocket Exposure Vulnerability in NitroSense and PredatorSense Software

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access...

6.9CVSS0.00253EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/17 8:05 a.m.4 views

EUVD-2026-81398

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. A WebSocket service was configured to listen on all network interfaces, which may expose the service to unintended network access...

6.9CVSS0.00253EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/09/17 7:59 a.m.8 views

CVE-2026-50606 Hard-coded Encryption Key Vulnerability in Acer System Monitoring for NitroSense and PredatorSense Software

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key ...

5.1CVSS0.00072EPSS
SaveExploits0References1
EUVD
EUVD
added 2026/09/17 7:59 a.m.4 views

EUVD-2026-81397

A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key ...

5.1CVSS0.00072EPSS
SaveExploits0References1
CVE
CVE
added 2026/09/17 7:59 a.m.6 views

CVE-2026-50606

A hard-coded AES encryption key in the Acer System Monitoring component (shipped with NitroSense and PredatorSense) allows a local attacker with no privileges to potentially access protected information or perform unauthorized actions under certain circumstances. The vulnerability is rated CVSS 4...

5.1CVSS0.00072EPSS
SaveExploits0References1
Rows per page
Query Builder