PT-2023-5477 · Schweitzer Engineering Laboratories · Acselerator Quickset

Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0 Description: The issue is related to an Inclusion of Functionality from Untrusted Control Sphere vulnerability, which could allow an attacker ...

6.5CVSS6.2AI score0.00394EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2023/04/24 12:0 a.m.6 views

PT-2023-5476 · Schweitzer Engineering Laboratories · Acselerator Quickset

Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0 Description: The issue is related to an Incomplete Filtering of Special Elements, which could allow an attacker to embed instructions that cou...

7.4CVSS7.2AI score0.00312EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2022/02/07 12:0 a.m.19 views

SEL (CVE-2013-0665) (deprecated)

Plugin deprecated because acselerator is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable- ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. @DEPRECATED@ Disabled on 2023/03/10. Deprecated because...

6.7AI score0.01186EPSS
SaveExploits0References2
ICS
ICS
added 2013/12/22 7:0 a.m.37 views

Schweitzer Engineering Laboratories AcSELerator Improper Authorization Vulnerability

Overview This advisory provides mitigation details for a vulnerability affecting the Schweitzer Engineering Laboratories SEL AcSELerator QuickSet software. Independent researcher Michael Toecker of Digital Bond has identified an improper authorization vulnerability in the SEL AcSELerator...

6.2CVSS6.2AI score0.01186EPSS
SaveExploits0References10
NVD
NVD
added 2013/03/21 2:55 p.m.20 views

CVE-2013-0665

Schweitzer Engineering Laboratories SEL AcSELerator QuickSet before 5.12.0.1 uses weak permissions for its Program Files directory, which allows local users to replace executable files, and consequently gain privileges, via standard filesystem operations...

6.2CVSS6.5AI score0.01186EPSS
SaveExploits0References1
Prion
Prion
added 2013/03/21 2:55 p.m.15 views

Code injection

Schweitzer Engineering Laboratories SEL AcSELerator QuickSet before 5.12.0.1 uses weak permissions for its Program Files directory, which allows local users to replace executable files, and consequently gain privileges, via standard filesystem operations...

6.2CVSS7AI score0.01186EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2013/03/21 2:0 p.m.67 views

CVE-2013-0665

The CVE affects SEL AcSELerator QuickSet prior to version 5.12.0.1. Root cause: weak permissions in the Program Files directory permit any local user to replace executables, enabling privilege escalation when the application runs. Impact per sources: local privilege compromise affecting the Quick...

6.2CVSS6.7AI score0.01186EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2013/03/21 2:0 p.m.24 views

CVE-2013-0665

Schweitzer Engineering Laboratories SEL AcSELerator QuickSet before 5.12.0.1 uses weak permissions for its Program Files directory, which allows local users to replace executable files, and consequently gain privileges, via standard filesystem operations...