447 matches found
Tenda AC8 安全漏洞
Tenda AC8 is a wireless router from Tenda, a Chinese company. A buffer overflow vulnerability exists in the Tenda AC8, which stems from a buffer overflow vulnerability in the shareSpeed parameter of the sub47D878 function, which can be exploited by an attacker to execute arbitrary code...
CVE-2025-0528
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2024-10123
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compareparentcontroltime of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be...
CVE-2024-10130
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. Th...
CVE-2024-11745
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function routestaticcheck of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploi...
CVE-2024-4065
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The...
CVE-2024-4064
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely...
CVE-2024-4066
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is...
Buffer overflow vulnerability in the schedEndTime parameter of the Tenda AC8 setSchedWifi function
Tenda AC8 is a wireless router from Tenda, a Chinese company. Tenda AC8 suffers from a buffer overflow vulnerability, which originates from the failure of the schedStartTime parameter of the setSchedWifi function in file /goform/openSchedWifi to correctly validate the length of the input data,...
Buffer overflow vulnerability in the schedEndTime parameter of the Tenda AC8 setSchedWifi function
Tenda AC8 is a wireless router from Tenda, a Chinese company. Tenda AC8 suffers from a buffer overflow vulnerability that originates from the failure of the schedEndTime parameter of the setSchedWifi function in the file /goform/openSchedWifi to correctly validate the length size of the input dat...
CVE-2025-0528
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2025-0528 Tenda AC8/AC10/AC18 HTTP Request telnet command injection
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2025-0528 Tenda AC8/AC10/AC18 HTTP Request telnet command injection
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
CVE-2025-0528: Improper Neutralization of Special Elements used in a Command
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched...
PT-2025-7558 · Tenda · Tenda Ac8
Name of the Vulnerable Software and Affected Versions: Tenda AC8 version 16.03.34.06 Description: The issue is related to a Buffer Overflow in the get parentControl list Info function. Recommendations: For Tenda AC8 version 16.03.34.06, consider disabling the get parentControl list Info function...
Tenda AC8 安全漏洞
Tenda AC8 is a wireless router from Tenda, a Chinese company. Tenda AC8 suffers from a buffer overflow vulnerability that originates from the failure of the schedEndTime parameter of the setSchedWifi function in the file /goform/openSchedWifi to correctly validate the length size of the input dat...
Tenda AC8 安全漏洞
Tenda AC8 is a wireless router from Tenda, a Chinese company. Tenda AC8 suffers from a buffer overflow vulnerability, which originates from the failure of the schedStartTime parameter of the setSchedWifi function in file /goform/openSchedWifi to correctly validate the length of the input data,...
PT-2025-1260 · Tenda · Tenda Ac10 +2
Name of the Vulnerable Software and Affected Versions: Tenda AC8 versions 16.03.10.20 Tenda AC10 versions 16.03.10.20 Tenda AC18 versions 16.03.10.20 Description: A critical issue has been found in the HTTP Request Handler component of the affected devices, specifically in the /goform/telnet file...
The vulnerability of the route_static_check function in the /goform/SetStaticRouteCfg function of the Tenda AC8 router software, which allows a attacker to compromise the confidentiality, integrity, and accessibility of data.
The vulnerability of the routeStaticCheck function in the /goform/SetStaticRouteCfg function of the Tenda AC8 router microsystem is related to buffer overflow in the stack. Exploiting this vulnerability could allow an attacker to compromise the confidentiality, integrity, and accessibility of dat...
Tenda AC8 Stack Overflow Vulnerability (CNVD-2025-09870)
The Tenda AC8 is a wireless router manufactured by Tenda for home and small business network connectivity. A stack overflow vulnerability exists in the Tenda AC8. The vulnerability originates in the parameter list of the routestaticcheck function in the /goform/SetStaticRouteCfg file and results ...