Lucene search
+L

563 matches found

CVE
CVE
•added 2024/03/26 4:00 p.m.•105 views

CVE-2024-2892

CVE-2024-2892 affects the Tenda AC7 router. The vulnerability is a stack-based overflow in the function formSetCfm (file /goform/setcfm) caused by manipulation of the funcpara1 parameter. It allows remote attack with public exploit disclosures and impacts confidentiality, integrity, and availabil...

9CVSS8.9AI score0.01684EPSS
SaveExploits1References4Affected Software1
OSV
OSV
•added 2024/03/26 2:15 p.m.•15 views

CVE-2024-2891

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

8.8CVSS6.2AI score0.01683EPSS
SaveExploits1References4
NVD
NVD
•added 2024/03/26 2:15 p.m.•33 views

CVE-2024-2891

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS8.9AI score0.01683EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
•added 2024/03/26 2:00 p.m.•33 views

CVE-2024-2891 Tenda AC7 QuickIndex formQuickIndex stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS8.9AI score0.01683EPSS
SaveExploits1References4
Cvelist
Cvelist
•added 2024/03/26 2:00 p.m.•38 views

CVE-2024-2891 Tenda AC7 QuickIndex formQuickIndex stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS9AI score0.01683EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•20 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts the 802.11ac standard and supports dual-band concurrent transmission with a wireless rate of up to 1167Mbps. Tenda AC7 suffers from a buffer overflow vulnerability that originates from a...

9CVSS7.4AI score0.01683EPSS
SaveExploits1References5
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•15 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts the 802.11ac standard and supports dual-band concurrent transmission with a wireless rate of up to 1167Mbps. Tenda AC7 suffers from a buffer overflow vulnerability that originates from a...

9CVSS7.4AI score0.01755EPSS
SaveExploits1References5
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•32 views

Tenda AC7 安全漏洞

Tenda AC7 is a wireless router from Tenda, China. A security vulnerability exists in Tenda AC7 version 15.03.06.44 due to a buffer overflow in the index parameter of the formWifiWpsOOB method...

9CVSS9.1AI score0.01683EPSS
SaveExploits1References5
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•15 views

Tenda AC7 操作系统命令注入漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts 802.11ac standard and supports dual-band concurrent transmission with wireless rate up to 1167Mbps. Tenda AC7 suffers from a command injection vulnerability that stems from a buffer...

8.8CVSS8.1AI score0.0783EPSS
SaveExploits2References5
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•16 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts the 802.11ac standard and supports dual-band concurrent transmission with a wireless rate of up to 1167Mbps. Tenda AC7 suffers from a buffer overflow vulnerability that originates from a...

9CVSS7.4AI score0.01683EPSS
SaveExploits1References5
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•17 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router from Tenda, designed for broadband upgrades and large households. The Tenda AC7 suffers from a buffer overflow vulnerability that originates from a buffer overflow vulnerability in the PPPOEPassword parameter of the formQuickIndex method. No detailed...

9CVSS7.5AI score0.01683EPSS
SaveExploits1References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•4 views

CVE-2024-2893: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The...

9CVSS6.2AI score0.01684EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•4 views

CVE-2024-2898: Stack-based Buffer Overflow

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The...

9CVSS6.2AI score0.01683EPSS
SaveExploits1References3
Positive Technologies
Positive Technologies
•added 2024/03/26 12:00 a.m.•21 views

PT-2024-2596 · Tenda · Tenda Ac7

Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44 Description: A critical issue has been discovered in the Tenda AC7, specifically in the function formSetCfm located in the "/goform/setcfm" file. This issue is caused by the manipulation of the funcpara1 argument...

9CVSS8.8AI score0.01684EPSS
SaveExploits1References8
Positive Technologies
Positive Technologies
•added 2024/03/26 12:00 a.m.•19 views

PT-2024-2598 · Tenda · Tenda Ac7

Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44 Description: The issue is caused by a stack-based buffer overflow in the formSetQosBand function of the /goform/SetNetControlList file. This can be exploited remotely, potentially affecting the confidentiality,...

9CVSS8.9AI score0.01584EPSS
SaveExploits1References10
Positive Technologies
Positive Technologies
•added 2024/03/26 12:00 a.m.•15 views

PT-2024-2600 · Tenda · Tenda Ac7

Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44 Description: The issue is caused by a stack-based buffer overflow in the formSetDeviceName function of the /goform/SetOnlineDevName file. This can be exploited remotely by manipulating the devName argument,...

9CVSS8.9AI score0.01684EPSS
SaveExploits1References10
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•4 views

CVE-2024-2891: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The...

9CVSS6.2AI score0.01683EPSS
SaveExploits1References3
CNNVD
CNNVD
•added 2024/03/26 12:00 a.m.•17 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts the 802.11ac standard and supports dual-band concurrent transmission with a wireless rate of up to 1167Mbps. Tenda AC7 suffers from a buffer overflow vulnerability that originates from a...

9CVSS7.4AI score0.01683EPSS
SaveExploits1References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/26 12:00 a.m.•5 views

CVE-2024-2896: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

9CVSS6.2AI score0.01856EPSS
SaveExploits1References3
Positive Technologies
Positive Technologies
•added 2024/03/26 12:00 a.m.•5 views

PT-2024-2597

Name of the Vulnerable Software and Affected Versions Tenda AC7 version 15.03.06.44 Description A critical issue affects the formWifiWpsOOB function of the /goform/WifiWpsOOB file, caused by a stack-based buffer overflow. The manipulation of the index argument leads to this overflow. The attack c...

9CVSS6.2AI score0.01683EPSS
SaveExploits1References9
Rows per page
Query Builder