CVE-2025-3346
CVE-2025-3346 affects Tenda AC7 (v15.03.06.44) due to a buffer overflow in the function formSetPPTPServer within /goform/SetPptpServerCfg. Manipulating pptp_server_start_ip/pptp_server_end_ip can overflow a buffer, potentially allowing remote code execution. Multiple connected sources confirm the...
CVE-2025-3346 Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptpserverstartip/pptpserverendip leads to buffer overflow. The attack may be launched...
CVE-2025-3346: Buffer Copy without Checking Size of Input
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptpserverstartip/pptpserverendip leads to buffer overflow. The attack may be launched...
Tenda AC7 安全漏洞
Tenda AC7 is a wireless router from Tenda, a Chinese company. A buffer overflow vulnerability exists in Tenda AC7 version 15.03.06.44, which is caused by improper handling of the pptpserverstartip/pptpserverendip parameters in the formSetPPTPServer function in the /goform/SetPptpServerCfg file...
PT-2025-15116 · Tenda · Tenda Ac7
Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44 Description: A critical issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp server start ip/pptp server end ip leads to buffer overflow. The...
Tenda AC7 Buffer Overflow Vulnerability
Tenda AC7 is a wireless router from Tenda, a Chinese company. The Tenda AC7 suffers from a buffer overflow vulnerability that originates from the formWifiBasicSet function failing to correctly validate the length and size of the input data, which can be exploited by an attacker to execute arbitra...
The vulnerability of the Telnet protocol implementation in the microprogramming-based router software Tenda AC7 allows a hacker to execute arbitrary commands.
The vulnerability of the Telnet protocol implementation in the Tenda AC7 microprogramming router software lies in the lack of measures taken to clean data at the management level when processing the lanip parameter. Exploiting this vulnerability allows a remote attacker to execute arbitrary...
Tenda AC7 Buffer Overflow Vulnerability (CNVD-2025-07593)
Tenda AC7 is a wireless router from Tenda, a Chinese company. The Tenda AC7 suffers from a buffer overflow vulnerability that originates from the timeZone parameter of the formfastsettingwifiset function failing to properly validate the length of the input data, which can be exploited by an...
CVE-2025-29135
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
CVE-2025-29135
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
CVE-2025-29135
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
Tenda AC7 安全漏洞
Tenda AC7 is a wireless router from Tenda, a Chinese company. The Tenda AC7 suffers from a buffer overflow vulnerability that originates from the formWifiBasicSet function failing to correctly validate the length and size of the input data, which can be exploited by an attacker to execute arbitra...
CVE-2025-29135: Stack-based Buffer Overflow
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
CVE-2025-29135
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
CVE-2025-29135
The Tenda AC7 wireless router (version 15.03.06.44 ) is vulnerable to a stack-based buffer overflow . This flaw occurs because the formWifiBasicSet function fails to correctly validate the length and size of input data provided via the security parameter. A remote attacker can exploit this to exe...
CVE-2025-29135
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
PT-2025-12706 · Tenda · Tenda Ac7
Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44 Description: A stack-based buffer overflow vulnerability allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function...
CVE-2025-29137
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the formfastsettingwifiset function, which can cause RCE...