289 matches found
CVE-2023-41561
Tenda AC9 V3.0 V15.03.06.42multi and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg...
CVE-2023-41559
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting...
CVE-2023-41557
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat...
PT-2023-27975 · Tenda · Tenda Ac7 +1
Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 1.0 V15.03.06.44 Tenda AC5 version 1.0RTL V15.03.06.28 Description: A stack overflow issue was discovered via parameter entrys and mitInterface at the "/goform/addressNat" API endpoint. Recommendations: For Tenda AC7 version...
CVE-2023-41557
CVE-2023-41557 affects Tenda AC7 (v1.0, v15.03.06.44) and Tenda AC5 (v1.0RTL, v15.03.06.28). A stack overflow is triggered via the entrys and mitInterface parameters at /goform/addressNat, enabling a high-severity, network-based impact with no user interaction. CVSS v3.1 indicates a critical base...
PT-2023-4719 · Tenda · Tenda Ac9 +1
Name of the Vulnerable Software and Affected Versions: Tenda AC9 versions V3.0 V15.03.06.42 multi Tenda AC5 versions US AC5V1.0RTL V15.03.06.28 Description: The issue is related to a stack overflow in the GetParentControlInfo function of Tenda AC9 and Tenda AC5 router software. This occurs when t...
CVE-2023-38935
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function...
CVE-2023-38937
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function...
CVE-2023-38935
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function...
CVE-2023-38933
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42multi, and FH1205 V2.0.0.7775 were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function...
CVE-2023-38930
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42multi and FH1205 V2.0.0.7775 were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function...
Stack overflow
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42multi and FH1205 V2.0.0.7775 were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function...
Design/Logic Flaw
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function...
CVE-2023-38936
CVE-2023-38936 concerns multiple Tenda devices (AC10, AC1206, AC6, AC7, AC5, FH1203, AC9, FH1205) where a stack overflow occurs in the function to set WAN speed (formSetSpeedWan) via the speed_dir parameter. Affected firmware versions include V15.03.06.xx ranges listed in the sources. The core is...
CVE-2023-38931
CVE-2023-38931 is a stack overflow in Tenda devices’ setaccount function when handling the list parameter, affecting multiple models (AC10, AC1206, AC8, AC6, AC7, F1203, AC5, FH1203, etc.). The root cause is improper handling/validation of the list parameter, enabling potential remote code execut...
CVE-2023-38933
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42multi, and FH1205 V2.0.0.7775 were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function...
CVE-2023-38930
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42multi and FH1205 V2.0.0.7775 were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function...
CVE-2023-37717
Tenda F1202 V1.0BRV1.2.0.20408 and FH1202V1.2.0.19EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient...
CVE-2023-37717
Tenda F1202 V1.0BRV1.2.0.20408 and FH1202V1.2.0.19EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient...
CVE-2023-37716
Tenda F1202 V1.0BRV1.2.0.20408 and FH1202V1.2.0.19EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting...