Lucene search
+L

294 matches found

Cvelist
Cvelist
•added 2023/02/27 12:00 a.m.•44 views

CVE-2023-25235

Tenda AC500 V2.0.1.91307 is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid...

7.7AI score0.11076EPSS
SaveExploits1References1
Vulnrichment
Vulnrichment
•added 2023/02/27 12:00 a.m.•11 views

CVE-2023-25235

Tenda AC500 V2.0.1.91307 is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid...

7.7AI score0.11076EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/02/27 12:00 a.m.•1 views

CVE-2023-25234: Out-of-bounds Write

Tenda AC500 V2.0.1.91307 is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface...

9.8CVSS5.9AI score0.16615EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/02/27 12:00 a.m.•1 views

CVE-2023-25233: Out-of-bounds Write

Tenda AC500 V2.0.1.91307 is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface...

9.8CVSS5.9AI score0.00966EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2023/02/27 12:00 a.m.•43 views

CVE-2023-25234

Tenda AC500 V2.0.1.91307 is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface...

9.7AI score0.16615EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
•added 2023/02/08 12:00 a.m.•27 views

PT-2023-19998 · Tenda · Tenda Ac500

Name of the Vulnerable Software and Affected Versions: Tenda AC500 version 2.0.1.91307 Description: The issue is related to a Buffer Overflow in the formOneSsidCfgSet function via the ssid parameter. Recommendations: For Tenda AC500 version 2.0.1.91307, as a temporary workaround, consider...

7.8CVSS7.4AI score0.11076EPSS
SaveExploits1References4
NVD
NVD
•added 2021/02/26 4:15 p.m.•32 views

CVE-2020-24686

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and...

7.5CVSS0.02498EPSS
SaveExploits0References1
Prion
Prion
•added 2021/02/26 4:15 p.m.•19 views

Design/Logic Flaw

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and...

5CVSS7.7AI score0.02498EPSS
SaveExploits0References1
CVE
CVE
•added 2021/02/26 3:10 p.m.•70 views

CVE-2020-24686

CVE-2020-24686 affects ABB AC500 V2 with onboard Ethernet. The issue is a denial of service in the PLC’s web visualization component: when exploited, the component stops responding and genuine users lose remote visibility of PLC state. If a user logs in while the vulnerability is exploited, the P...

7.5CVSS7.7AI score0.02498EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/02/26 12:00 a.m.•6 views

CVE-2020-24686: Uncontrolled Resource Consumption

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and...

7.5CVSS6AI score0.02498EPSS
SaveExploits0References3
OSV
OSV
•added 2021/02/09 4:15 a.m.•17 views

CVE-2020-24685

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS5.8AI score0.01608EPSS
SaveExploits0References1
NVD
NVD
•added 2021/02/09 4:15 a.m.•28 views

CVE-2020-24685

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS0.01608EPSS
SaveExploits0References1
Prion
Prion
•added 2021/02/09 4:15 a.m.•38 views

Design/Logic Flaw

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

5CVSS8.2AI score0.01608EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2021/02/09 3:57 a.m.•81 views

CVE-2020-24685

CVE-2020-24685 affects ABB AC500 V2 with onboard Ethernet versions 2.8.4 and earlier. An unauthenticated, specially crafted network packet can cause a denial-of-service by stopping the PLC; after stop, physical access is required to restart the application. Public documents describe the vulnerabi...

8.6CVSS8.4AI score0.01608EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2021/02/09 3:57 a.m.•39 views

CVE-2020-24685 AC500 V2 unauthenticated crafter packet vulnerability

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS8.3AI score0.01608EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2021/02/09 12:00 a.m.•18 views

ABB Asea Brown Boveri Ltd ABB AC500 V2 Security Breach

ABB Asea Brown Boveri Ltd ABB AC500 V2 is a PLC from ABB Asea Brown Boveri Ltd, Sweden.Suitable for simple control tasks and complex automation solutions. ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions contain a security vulnerability that can be exploited by an...

8.6CVSS5.8AI score0.01608EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/02/09 12:00 a.m.•6 views

CVE-2020-24685: Memory Allocation with Excessive Size Value

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS5.8AI score0.01608EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•18 views

ABB 1SAP373800R0001 CM598-CN-XC AC500 Communications Adapter Detection

Binary data 756461.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•12 views

ABB 1SAP351000R0278 PM5670-2ETH-XC AC500 PLC Detection

Binary data 756451.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•14 views

ABB 1SAP311300R0278 TB5610-2ETH-XC AC500 Terminal Base Detection

Binary data 756439.prm...

7.3AI score
SaveExploits0
Rows per page
Query Builder