Lucene search
+L

865 matches found

CVE
CVE
added 2022/11/21 12:00 a.m.92 views

CVE-2022-44171

CVE-2022-44171 affects Tenda AC18 router (firmware 15.03.05.19). Vulnerability: buffer overflow in function form_fast_setting_wifi_set. CVSS v3.1 vector indicates network access, no privileges, no user interaction, with high impact to confidentiality, integrity, and availability (base score 9.8)....

9.8CVSS9.4AI score0.00701EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/11/21 12:00 a.m.10 views

Tenda AC18 安全漏洞

Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 suffers from a buffer overflow vulnerability that stems from the presence of a buffer overflow via the SetRouteStatic function. No detailed...

9.8CVSS7.5AI score0.00775EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/11/21 12:00 a.m.45 views

CVE-2022-44171

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formfastsettingwifiset...

9.7AI score0.00701EPSS
SaveExploits0References1
CVE
CVE
added 2022/11/21 12:00 a.m.79 views

CVE-2022-44176

CVE-2022-44176 affects Tenda AC18 firmware version 15.03.05.19. The vulnerability is described as a buffer overflow triggered by the SetRouteStatic function (fromSetRouteStatic). The CVSS metrics indicate a critical impact (C/H/I/A = High) with network access, low attack complexity, and no privil...

9.8CVSS9.4AI score0.00775EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/11/21 12:00 a.m.29 views

CVE-2022-44176

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic...

9.7AI score0.00775EPSS
SaveExploits0References1
CVE
CVE
added 2022/11/21 12:00 a.m.93 views

CVE-2022-44180

CVE-2022-44180 affects Tenda AC18, version V15.03.05.19. The vulnerability is a buffer overflow in addWifiMacFilter , enabling a potential denial of service. Multiple sources confirm the affected product/version and function, with impact described as high (CVE/NVD). Public details do not specify ...

9.8CVSS9.4AI score0.00701EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/11/21 12:00 a.m.10 views

Tenda AC18 安全漏洞

The Tenda AC18 is a router from the Chinese company Tenda. A buffer overflow vulnerability exists in Tenda AC18 version V15.03.05.19, which is caused by the formWifiWpsStart function not checking the length and size of the input data, and can be exploited by an attacker to cause a denial of servi...

9.8CVSS7.2AI score0.00701EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2022/11/21 12:00 a.m.9 views

CVE-2022-44172

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler...

9.5AI score0.00701EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/11/21 12:00 a.m.44 views

CVE-2022-44180

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter...

9.7AI score0.00701EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/11/21 12:00 a.m.45 views

CVE-2022-44183

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic...

9.7AI score0.0103EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/11/21 12:00 a.m.10 views

CVE-2022-44177

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart...

9.5AI score0.00701EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/11/21 12:00 a.m.7 views

CVE-2022-44176

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic...

9.5AI score0.00775EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2022/11/21 12:00 a.m.11 views

Tenda AC18 安全漏洞

Tenda AC18 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in July 2016, mainly for villas and large home users. Tenda AC18 suffers from a buffer overflow vulnerability, which stems from the formfastsettingwifiset function that allows an attacker to implement a...

9.8CVSS7.5AI score0.00701EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2022/11/21 12:00 a.m.43 views

CVE-2022-44177

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart...

9.7AI score0.00701EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/11/21 12:00 a.m.17 views

PT-2022-27139 · Tenda · Tenda Ac18

Name of the Vulnerable Software and Affected Versions: Tenda AC18 version 15.03.05.19 Description: The issue is related to a Buffer Overflow that can be triggered via the addWifiMacFilter function. Recommendations: For Tenda AC18 version 15.03.05.19, consider disabling the addWifiMacFilter functi...

9.8CVSS9.3AI score0.00701EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2022/11/21 12:00 a.m.11 views

PT-2022-27135 · Tenda · Tenda Ac18

Name of the Vulnerable Software and Affected Versions: Tenda AC18 version 15.03.05.19 Description: The issue is related to a Buffer Overflow that can be triggered via the formSetMacFilterCfg function. Recommendations: For Tenda AC18 version 15.03.05.19, consider disabling the formSetMacFilterCfg...

9.8CVSS7.2AI score0.00775EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2022/11/21 12:00 a.m.16 views

PT-2022-27140 · Tenda · Tenda Ac18

Name of the Vulnerable Software and Affected Versions: Tenda AC18 version 15.03.05.19 Description: The issue is related to a Buffer Overflow that can be triggered via the formSetWifiGuestBasic function. This allows for potential exploitation. Recommendations: For Tenda AC18 version 15.03.05.19,...

9.8CVSS9.2AI score0.0103EPSS
SaveExploits0References3
CVE
CVE
added 2022/11/21 12:00 a.m.86 views

CVE-2022-44172

The CVE-2022-44172 entry concerns Tenda AC18, version 15.03.05.19, vulnerable to a buffer overflow in the R7WebsSecurityHandler function. The connected sources collectively confirm the affected device and the vulnerable component but provide no concrete exploit details or mitigation/fix informati...

9.8CVSS9.4AI score0.00701EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/11/21 12:00 a.m.88 views

CVE-2022-44174

The CVE-2022-44174 entry concerns Tenda AC18 firmware (version 15.03.05.05) with a buffer overflow in the formSetDeviceName function. Public sources consistently describe a buffer overflow that can be triggered via this function, impacting the device’s integrity and availability; CVSS v3.1 has a ...

9.8CVSS9.4AI score0.00701EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/11/21 12:00 a.m.12 views

CVE-2022-44183

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic...

9.5AI score0.0103EPSS
SaveExploits0References1
Rows per page
Query Builder