Lucene search
+L

901 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•10 views

CVE-2024-2808: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiate...

9.8CVSS6.2AI score0.01372EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•20 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol with a theoretical transmission rate of 1900Mbps 600Mbps in 2.4GHz band and 1300Mbps in 5GHz band. The Tenda AC15 suffers from a stack buffer overflow...

9.8CVSS8.2AI score0.01372EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•21 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol with a theoretical transmission rate of 1900Mbps 600Mbps in 2.4GHz band and 1300Mbps in 5GHz band. Tenda AC15 suffers from a stack buffer overflow...

9.8CVSS8.3AI score0.01541EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•18 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol with a theoretical transmission rate of 1900Mbps 600Mbps in 2.4GHz band and 1300Mbps in 5GHz band. Tenda AC15 suffers from a stack buffer overflow...

9CVSS8.2AI score0.01605EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•16 views

Tenda AC15 安全漏洞

The Tenda AC15 is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in Tenda AC15 version 15.03.20multi, which originates from the ssid parameter in the formfastsettingwifiset method of the /goform/fastsettingwifiset page that fails to correctly validate the...

9.8CVSS8.2AI score0.01315EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•5 views

CVE-2024-2805: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speeddir leads to stack-based buffer overflow. The attack may be launched...

9CVSS6.2AI score0.01605EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•6 views

CVE-2024-2809: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the atta...

9.8CVSS6.2AI score0.01918EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•23 views

Tenda AC15 安全漏洞

The Tenda AC15 is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in Tenda AC15 version 15.03.05.18, which originates from the deviceId/deviceMac parameter in the addWifiMacFilter method of the /goform/addWifiMacFilter page that fails to correctly validate...

9.8CVSS8.2AI score0.01315EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•18 views

Tenda AC15 安全漏洞

Tenda AC15 is a wireless router from Tenda, China. A security vulnerability exists in the Tenda AC15 version 15.03.20multi, which is caused by a stack-based buffer overflow in the password parameter of the R7WebsSecurityHandler method on the /goform/execCommand page...

9.8CVSS9.2AI score0.01315EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•17 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol with a theoretical transmission rate of 1900Mbps 600Mbps in 2.4GHz band and 1300Mbps in 5GHz band. Tenda AC15 suffers from a stack buffer overflow...

9.8CVSS8.3AI score0.01315EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•7 views

CVE-2024-2813: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC15 15.03.20multi. It has been declared as critical. This vulnerability affects the function formfastsettingwifiset of the file /goform/fastsettingwifiset. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated...

9.8CVSS6.2AI score0.01315EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•25 views

Tenda AC15 安全漏洞

Tenda AC15 is a wireless router from Tenda, China. A security vulnerability exists in the Tenda AC15 version 15.03.05.18, which is caused by a stack-based buffer overflow in the firewallEn parameter of the formSetFirewallCfg method on the /goform/SetFirewallCfg page...

9.8CVSS9.2AI score0.01918EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•5 views

CVE-2024-2806: Stack-based Buffer Overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the...

9.8CVSS6.2AI score0.01315EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•4 views

CVE-2024-2814: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC15 15.03.20multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploi...

9.8CVSS6.3AI score0.01315EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/22 12:00 a.m.•9 views

CVE-2024-2815: Stack-based Buffer Overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.20multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to laun...

9.8CVSS6.2AI score0.01315EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2024/03/22 12:00 a.m.•22 views

Tenda AC15 安全漏洞

Tenda AC15 is a dual-band wireless router launched by Shenzhen Jixiang Tenda Technology Co. in October 2015, which supports 802.11ac protocol with a theoretical transmission rate of 1900Mbps 600Mbps in 2.4GHz band and 1300Mbps in 5GHz band. Tenda AC15 suffers from a stack buffer overflow...

9.8CVSS8.3AI score0.01372EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
•added 2024/03/16 12:00 a.m.•6 views

PT-2024-2393

Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.20 multi Description A critical issue affects the saveParentControlInfo function of the file "/goform/saveParentControlInfo". The manipulation of the urls argument leads to a stack-based buffer overflow. This can be...

9.8CVSS0.01298EPSS
SaveExploits1References8
Positive Technologies
Positive Technologies
•added 2024/03/16 12:00 a.m.•27 views

PT-2024-2386 · Tenda · Tenda Ac15

Name of the Vulnerable Software and Affected Versions: Tenda AC15 versions 15.03.05.18 through 15.03.20 multi Description: The issue is related to the function formSetSambaConf at the /goform/setsambacfg endpoint, where the usbName parameter is not properly sanitized, leading to OS command...

9.8CVSS7.2AI score0.04009EPSS
SaveExploits1References7
Positive Technologies
Positive Technologies
•added 2024/03/14 12:00 a.m.•17 views

PT-2024-2403 · Tenda · Tenda Ac15

Name of the Vulnerable Software and Affected Versions: Tenda AC15 versions 15.03.05.18 through 15.03.20 multi Description: A critical issue has been found in the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to a stack-based buffer...

10CVSS8.9AI score0.01372EPSS
SaveExploits1References8
Positive Technologies
Positive Technologies
•added 2024/03/14 12:00 a.m.•31 views

PT-2024-2407 · Tenda · Tenda Ac15

Name of the Vulnerable Software and Affected Versions: Tenda AC15 versions 15.03.05.18 through 15.03.20 multi Description: A critical issue affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection, allowing remote...

9CVSS7.1AI score0.0405EPSS
SaveExploits1References7
Rows per page