Lucene search
+L

745 matches found

Positive Technologies
Positive Technologies
added 2026/03/27 12:0 a.m.5 views

PT-2026-28700

Name of the Vulnerable Software and Affected Versions Tenda AC15 version 15.03.05.19 Description A flaw exists in the Tenda AC15 router that allows remote attackers to trigger a stack-based buffer overflow. The issue is located within the POST Request Handler component, specifically in the...

9CVSS6.4AI score0.00632EPSS
Exploits1References8
RedhatCVE
RedhatCVE
added 2026/03/04 1:57 a.m.6 views

CVE-2026-24103

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18multi...

9.8CVSS6.1AI score0.00425EPSS
Exploits1References1
OSV
OSV
added 2026/03/03 3:16 p.m.7 views

CVE-2026-24103

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18multi...

9.8CVSS6AI score0.00425EPSS
Exploits1References2
NVD
NVD
added 2026/03/03 3:16 p.m.6 views

CVE-2026-24103

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18multi...

9.8CVSS0.00425EPSS
Exploits1References2
RedhatCVE
RedhatCVE
added 2026/03/03 1:48 a.m.5 views

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18multi. When the condition is met, s11 will be passed into subB0488, concatenated into doSystemCmd. The value of s11 is not validated, potentially leading to a command injection vulnerability...

9.8CVSS5.9AI score0.01671EPSS
Exploits1References1
RedhatCVE
RedhatCVE
added 2026/03/03 1:48 a.m.7 views

CVE-2026-3400

A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapskcrypto24g results in stack-based buffer overflow. The attack may be launched remotely. The...

9.8CVSS7.7AI score0.00853EPSS
Exploits1References1
EUVD
EUVD
added 2026/03/03 12:0 a.m.3 views

EUVD-2026-9293

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18multi...

6.1AI score0.00425EPSS
Exploits1References2
CNNVD
CNNVD
added 2026/03/03 12:0 a.m.9 views

Tenda AC15 安全漏洞

The Tenda AC15 is a wireless router produced by the Chinese company Tenda. The Tenda AC15 V15.03.05.18multi version has a security vulnerability, which stems from a buffer overflow in the goform/formSetMacFilterCfg component...

9.8CVSS6AI score0.00425EPSS
Exploits1References2
Positive Technologies
Positive Technologies
added 2026/03/03 12:0 a.m.7 views

PT-2026-22745

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18 multi...

6.1AI score0.00425EPSS
Exploits1References3
Vulnrichment
Vulnrichment
added 2026/03/03 12:0 a.m.4 views

CVE-2026-24103

A buffer overflow vulnerability was discovered in goform/formSetMacFilterCfg in Tenda AC15V1.0 V15.03.05.18multi...

6.1AI score0.00425EPSS
Exploits1References2
CVE
CVE
added 2026/03/03 12:0 a.m.10 views

CVE-2026-24103

A buffer overflow vulnerability is reported in the Tenda AC15 router (V1.0, firmware version V15.03.05.18_multi) in the goform/formSetMacFilterCfg function. The issue is described across multiple sources as CVE-2026-24103 with a high-impact profile (CVSS v3.1: Network vector, High confidentiality...

9.8CVSS6.1AI score0.00425EPSS
Exploits1References2Affected Software1
OSV
OSV
added 2026/03/02 5:16 p.m.3 views

CVE-2026-24105

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18multi. The value of v1 was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd...

9.8CVSS5.9AI score0.01704EPSS
Exploits1References2
NVD
NVD
added 2026/03/02 5:16 p.m.7 views

CVE-2026-24105

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18multi. The value of v1 was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd...

9.8CVSS0.01704EPSS
Exploits1References2
OSV
OSV
added 2026/03/02 4:16 p.m.9 views

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18multi. When the condition is met, s11 will be passed into subB0488, concatenated into doSystemCmd. The value of s11 is not validated, potentially leading to a command injection vulnerability...

9.8CVSS5.8AI score0.01671EPSS
Exploits1References2
NVD
NVD
added 2026/03/02 4:16 p.m.12 views

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18multi. When the condition is met, s11 will be passed into subB0488, concatenated into doSystemCmd. The value of s11 is not validated, potentially leading to a command injection vulnerability...

9.8CVSS0.01671EPSS
Exploits1References2
NVD
NVD
added 2026/03/02 12:16 a.m.10 views

CVE-2026-3400

A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapskcrypto24g results in stack-based buffer overflow. The attack may be launched remotely. The...

9.8CVSS0.00853EPSS
Exploits1References5
EUVD
EUVD
added 2026/03/02 12:0 a.m.8 views

EUVD-2026-9203

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18multi. The value of v1 was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd...

6AI score0.01704EPSS
Exploits1References2
ATTACKERKB
ATTACKERKB
added 2026/03/02 12:0 a.m.2 views

CVE-2026-24105

An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18multi. The value of v1 was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd...

9.8CVSS6AI score0.01704EPSS
Exploits1References3
Vulnrichment
Vulnrichment
added 2026/03/02 12:0 a.m.3 views

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18multi. When the condition is met, s11 will be passed into subB0488, concatenated into doSystemCmd. The value of s11 is not validated, potentially leading to a command injection vulnerability...

5.9AI score0.01671EPSS
Exploits1References2
ATTACKERKB
ATTACKERKB
added 2026/03/02 12:0 a.m.3 views

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18multi. When the condition is met, s11 will be passed into subB0488, concatenated into doSystemCmd. The value of s11 is not validated, potentially leading to a command injection vulnerability...

9.8CVSS5.9AI score0.01671EPSS
Exploits1References3
Rows per page
Query Builder