Lucene search
+L

922 matches found

Cvelist
Cvelist
•added 2024/04/17 12:00 a.m.•35 views

CVE-2024-32317

Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function...

7.3AI score0.00403EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
•added 2024/04/17 12:00 a.m.•5 views

PT-2024-24505

Name of the Vulnerable Software and Affected Versions Tenda AC10 v4.0 V16.03.10.13 Tenda AC10 v4.0 V16.03.10.20 Description The issue is a stack overflow vulnerability. It occurs via the adslPwd parameter in the formWanParameterSetting function. Recommendations For Tenda AC10 v4.0 V16.03.10.13,...

7.5CVSS5.8AI score0.00403EPSS
SaveExploits1References6
BDU FSTEC
BDU FSTEC
•added 2024/03/27 12:00 a.m.•20 views

The vulnerability of the fromSetSysTime() function (/goform/SetSysTimeCfg) in the Tenda AC10 router’s microprogramming software allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the fromSetSysTime function /goform/SetSysTimeCfg in the Tenda AC10 router’s microprogramming system is related to the operation where the output goes beyond the buffer in memory when processing the timeZone parameter. Exploiting this vulnerability can allow an attacker to...

9CVSS7.8AI score0.01159EPSS
SaveExploits1References3Affected Software1
OSV
OSV
•added 2024/03/24 7:15 a.m.•22 views

CVE-2024-2856

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...

9.8CVSS6.4AI score0.01159EPSS
SaveExploits1References4
NVD
NVD
•added 2024/03/24 7:15 a.m.•34 views

CVE-2024-2856

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...

9.8CVSS9.2AI score0.01159EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
•added 2024/03/24 6:31 a.m.•17 views

CVE-2024-2856 Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...

9CVSS9.6AI score0.01159EPSS
SaveExploits1References4
Cvelist
Cvelist
•added 2024/03/24 6:31 a.m.•48 views

CVE-2024-2856 Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...

9CVSS9.7AI score0.01159EPSS
SaveExploits1References4
CVE
CVE
•added 2024/03/24 6:31 a.m.•89 views

CVE-2024-2856

The CVE-2024-2856 vulnerability affects Tenda AC10 firmware 16.03.10.13/16.03.10.20. The issue is in the function fromSetSysTime of /goform/SetSysTimeCfg, where manipulating the timeZone parameter causes a stack-based buffer overflow. It can be triggered remotely and public exploits have been dis...

9.8CVSS8.8AI score0.01159EPSS
SaveExploits1References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/24 12:00 a.m.•4 views

CVE-2024-2856: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be...

9.8CVSS6.2AI score0.01159EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2024/03/24 12:00 a.m.•20 views

Tenda AC10 操作系统命令注入漏洞

Tenda AC10 is a wireless router from Tenda, China. An OS command injection vulnerability exists in Tenda AC10U version 15.03.06.48, which originates from an OS command injection in the usbName parameter of the formSetSambaConf method on the /goform/setsambacfg page...

9.8CVSS7AI score0.04009EPSS
SaveExploits1References4
CNNVD
CNNVD
•added 2024/03/24 12:00 a.m.•20 views

Tenda AC10 安全漏洞

Tenda AC10 is a wireless router from Tenda, China. A security vulnerability exists in Tenda AC10 version 16.03.10.13, which is caused by a stack-based buffer overflow in the timeZone parameter of the fromSetSysTime method on the /goform/SetSysTimeCfg page...

9.8CVSS9.1AI score0.01159EPSS
SaveExploits1References4
CNVD
CNVD
•added 2024/03/22 12:00 a.m.•17 views

Tenda AC10 setSchedWifi function buffer overflow vulnerability

The Tenda AC10 is a wireless router from the Chinese company Tenda. A buffer overflow vulnerability exists in Tenda AC10U version 15.03.06.49, which originates from the failure of the schedStartTime parameter of the setSchedWifi function in the /goform/openSchedWifi file to correctly validate the...

9CVSS8.2AI score0.01482EPSS
SaveExploits1References1
BDU FSTEC
BDU FSTEC
•added 2024/03/22 12:00 a.m.•17 views

The vulnerability of the fromSetRouteStatic() function (/goform/SetStaticRouteCfg) in the Tenda AC10 router software allows a hacker to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the fromSetRouteStatic function /goform/SetStaticRouteCfg in the Tenda AC10 router software lies in the issue where the operation exits the buffer boundaries in memory when processing the list parameter. Exploiting this vulnerability could allow an attacker to compromise the...

9CVSS7.8AI score0.01303EPSS
SaveExploits1References3Affected Software1
CNVD
CNVD
•added 2024/03/21 12:00 a.m.•41 views

Tenda AC10 Buffer Overflow Vulnerability (CNVD-2024-34381)

The Tenda AC10 is a wireless router from the Chinese company Tenda. The Tenda AC10 suffers from a buffer overflow vulnerability, which originates from the parameter list of the fromSetRouteStatic function in file /goform/SetStaticRouteCfg that fails to correctly validate the length of the input...

9CVSS8.2AI score0.01303EPSS
SaveExploits1References1
OSV
OSV
•added 2024/03/18 3:15 a.m.•15 views

CVE-2024-2581

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...

8.8CVSS6.3AI score0.01303EPSS
SaveExploits1References3
NVD
NVD
•added 2024/03/18 3:15 a.m.•36 views

CVE-2024-2581

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...

9CVSS8.9AI score0.01303EPSS
SaveExploits1References3
CVE
CVE
•added 2024/03/18 3:00 a.m.•103 views

CVE-2024-2581

The CVE-2024-2581 vulnerability affects Tenda AC10 firmware 16.03.10.13, specifically the fromSetRouteStatic() function in /goform/SetStaticRouteCfg. The issue is a stack-based buffer overflow triggered by manipulating the list parameter, permitting remote exploitation. Multiple sources confirm i...

9CVSS9AI score0.01303EPSS
SaveExploits1References3Affected Software1
Vulnrichment
Vulnrichment
•added 2024/03/18 3:00 a.m.•17 views

CVE-2024-2581 Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...

9CVSS8.9AI score0.01303EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2024/03/18 3:00 a.m.•41 views

CVE-2024-2581 Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...

9CVSS9.1AI score0.01303EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/18 12:00 a.m.•6 views

CVE-2024-2581: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit h...

9CVSS6.3AI score0.01303EPSS
SaveExploits1References3
Rows per page