2013 matches found
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems ICS advisories on February 6, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-037-01 Schneider Electric EcoStruxure Power Monitoring Expert PME ICSA-25-037-02...
CVE-2024-51547
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.; NEXUS Series: through 3.; MATRIX Series: through 3...
CVE-2024-51547
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.; NEXUS Series: through 3.; MATRIX Series: through 3...
CVE-2024-51547 Credentials Disclosure - keys
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.; NEXUS Series: through 3.; MATRIX Series: through 3...
CVE-2024-51547
CVE-2024-51547 affects ABB ASPECT-Enterprise, ABB NEXUS Series and ABB MATRIX Series (firmware up to 3.08.03). The vulnerability stems from hard-coded credentials embedded in multiple components, enabling unauthorized access and potentially compromising confidentiality, integrity and availability...
CVE-2024-51547 Credentials Disclosure - keys
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.; NEXUS Series: through 3.; MATRIX Series: through 3...
CVE-2022-0010
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could...
CVE-2019-18998
Insufficient access control in the web interface of ABB Asset Suite versions 9.0 to 9.3, 9.4 prior to 9.4.2.6, 9.5 prior to 9.5.3.2 and 9.6.0 enables full access to directly referenced objects. An attacker with knowledge of a resource's URL can access the resource directly...
CVE-2019-19104
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator URL , violating the access-control ACL rules. This issue allows obtaining...
CVE-2019-19094
Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database...
CVE-2019-19106
Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings...
CVE-2020-8474
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction...
CVE-2020-8485
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash...
CVE-2020-8481
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody...
CVE-2020-8489
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management all published versions enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management...
CVE-2020-8477
The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code...
CVE-2020-8482
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data...
CVE-2020-8473
Insufficient folder permissions used by system functions in ABB System 800xA Base version 6.1 and earlier allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her...
CVE-2020-8484
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash...
CVE-2020-8471
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...