2013 matches found
ABB M2M Gateway Use-After-Free in embedded Linux Kernel (CVE-2022-3564)
A vulnerability classified as critical was found in Linux Kernel. Affected by this vulnerability is the function l2capreassemblesdu of the file net/bluetooth/l2capcore.c of the component Bluetooth. The manipulation leads to use after free. It is recommended to apply a patch to fix this issue. The...
ABB M2M Gateway Arbitrary Code Execution in embedded OpenSSH (CVE-2016-10009)
Untrusted search path vulnerability in ssh-agent.c in ssh-agent in OpenSSH before 7.4 allows remote attackers to execute arbitrary local PKCS11 modules by leveraging control over a forwarded agent-socket. This plugin only works with Tenable.ot. Please visit...
ABB Cylon Aspect Studio 3.08.03 - Binary Planting
Exploit Title: ABB Cylon Aspect Studio 3.08.03 - Binary Planting Vendor: ABB Ltd. Product web page: https://www.global.abb Affected version: type project P R O J E C T .| | | |'| . | | |. |' .---"| .-' '-. | | .--'| || | | | .-'| .| | || '- | | | || | |' | |. | || | | | | || | | '-' ' "" '-' '-.'...
ABB Cylon Aspect 3.08.03 - Guest2Root Privilege Escalation
!/usr/bin/env python Exploit Title: ABB Cylon Aspect 3.08.03 - Guest2Root Privilege Escalation Vendor: ABB Ltd. Product web page: https://www.global.abb Affected version: NEXUS Series, MATRIX-2 Series, ASPECT-Enterprise, ASPECT-Studio Firmware: =3.08.03 Summary: ASPECT is an award-winning scalabl...
CVE-2023-0863
Improper Authentication vulnerability in ABB Terra AC wallbox UL40/80A, ABB Terra AC wallbox UL32A, ABB Terra AC wallbox CE Terra AC MID, ABB Terra AC wallbox CE Terra AC Juno CE, ABB Terra AC wallbox CE Terra AC PTB, ABB Terra AC wallbox CE Symbiosis, ABB Terra AC wallbox JP.This issue affects...
CVE-2022-3192
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6...
📄 ABB Cylon Aspect 3.08.03 logMixDownload.php Remote Code Execution
The ABB BMS/BAS controller suffers from an authenticated blind OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through the 'instance' HTTP POST parameter called by the logMixDownload.php script and dependant on SELECTED=ALL case. Version...
CVE-2021-27414
An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management EAM versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials...
CVE-2020-8476
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
CVE-2020-8472
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M versions 6.0 and earlier and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl version 6.1 and earlier allow low privileged users to read, modify, add and...
CVE-2020-8475
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
CVE-2020-8487
Insufficient protection of the inter-process communication functions in ABB System 800xA Base all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling...
CVE-2020-8486
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling...
CVE-2020-8478
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl all published versions enables an attacker authenticated on the local system to inject data, affecting the online view...
CVE-2019-7229
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of...
CVE-2019-19001
For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user information such as authentication credentia...
CVE-2019-19003
For ABB eSOMS versions 4.0 to 6.0.2, the HTTPOnly flag is not set. This can allow Javascript to access the cookie contents, which in turn might enable Cross Site Scripting...
CVE-2019-19000
For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP headers have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information...
CVE-2019-19002
For ABB eSOMS versions 4.0 to 6.0.2, the X-XSS-Protection HTTP response header is not set in responses from the web server. For older web browser not supporting Content Security Policy, this might increase the risk of Cross Site Scripting...
CVE-2019-19091
For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. An attacker might use this detail information to specifically craft the attack...