2013 matches found
CVE-2025-10205
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions...
CVE-2024-48851
CVE-2024-48851 affects ABB FLXEON controllers (through version 9.3.5). The issue arises from improper input validation in the FLXEON.A component, enabling remote code execution. Connected sources (ICS advisory from CISA, vendor/Red Hat/CNNVD entries) confirm remote code execution as the impact. N...
CVE-2024-48842
Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions...
CVE-2025-10205
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions...
CVE-2025-10205 Predictable Salt and Weak Hashing Algorithm
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions...
CVE-2024-48842 Hardcoded passwords
Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions...
PT-2025-38219
Name of the Vulnerable Software and Affected Versions: ABB FLXEON versions through 9.3.5 and newer versions Description: The software uses a one-way hash with a predictable salt. Recommendations: At the moment, there is no information about a newer version that contains a fix for this vulnerabili...
CISA Releases Fourteen Industrial Control Systems Advisories
CISA released fourteen Industrial Control Systems ICS advisories on September 9, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-252-01 Rockwell Automation ThinManager ICSA-25-252-02 ABB Cylon Aspect BMS/BAS...
CVE-2025-8754 ABB AbilityTM zenon Remote Transport Vulnerability
Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14...
CVE-2025-7677
CVE-2025-7677 affects ABB Aspect (industrial control system) with a DoS caused by a buffer copy issue. According to ICSA-25-252-02, the DoS affects all versions of ASPECT, with specific note that versions prior to 3.08.04-s01 are impacted. The DoS is exploitable if an attacker has access to the l...
编号撤回
ABB ASPECT is a scalable building energy management and control solution from ABB Switzerland. This CVE number has been withdrawn...
CVE-2025-7745
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7705
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
CVE-2025-7745
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745 Modbus TCP buffer overread
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745 Modbus TCP buffer overread
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2...
CVE-2025-7745
CVE-2025-7745 is a buffer over-read vulnerability in ABB AC500 V2. The issue affects AC500 V2 up to version 2.5.2. Publicly available technical details specify a buffer over-read in ABB AC500 V2, with potential for abnormal behavior. The PT-2025-30638 advisory recommends updating ABB AC500 V2 to ...
PT-2025-30638
Name of the Vulnerable Software and Affected Versions ABB AC500 V2 versions through 2.5.2 Description A buffer over-read issue exists in ABB AC500 V2. This can potentially lead to unexpected system behavior. Recommendations Update ABB AC500 V2 to a version later than 2.5.2...
CVE-2025-7705
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions...
CVE-2025-7705
CVE-2025-7705 affects ABB Switch Actuator 4 DU-83330 and ABB Switch actuator, door/light 4 DU-83330-500, all versions. The issue is described as an Active Debug Code vulnerability. The PT-2025-30398 entry confirms the vulnerable components and versions and states there is no information about a f...