Lucene search
+L

2048 matches found

Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•18 views

ABB OPC Server for Incorrect Permission Assignment for Critical Resource (CVE-2021-22284)

Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

8.8CVSS8.4AI score0.00831EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•28 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8486)

Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling. This plugin only works with Tenable.ot. Please visit...

7.8CVSS7.3AI score0.0033EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•24 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8488)

Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management all published versions enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities. Th...

7.8CVSS7.4AI score0.00406EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•26 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8484)

Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. This plugin only works wi...

7.8CVSS7.3AI score0.0034EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•26 views

ABB System 800xA Incorrect Default Permissions (CVE-2020-8473)

Insufficient folder permissions used by system functions in ABB System 800xA Base version 6.1 and earlier allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her...

7.8CVSS7.4AI score0.00291EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•31 views

ABB Central Licensing System Improper Restriction of XML External Entity Reference (CVE-2020-8479)

For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...

9.8CVSS7.7AI score0.02259EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•28 views

ABB System 800xA Base Incorrect Permission Assignment For Critical Resource (CVE-2020-8474)

Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction. This plugin only works with Tenable.ot. Please visit...

7.8CVSS7.4AI score0.00297EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•31 views

ABB AC500 Allocation of Resources Without Limits or Throttling (CVE-2020-24685)

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS7.8AI score0.01608EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•33 views

ABB Central Licensing System Uncontrolled Resource Consumption (CVE-2020-8475)

For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...

7.5CVSS7.3AI score0.01548EPSS
SaveExploits1References5
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•30 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8485)

Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 all published versions enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. This plugin only work...

7.8CVSS7.3AI score0.0034EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•42 views

ABB Central Licensing System Exposure of Sensitive Information to an Unauthorized Actor (CVE-2020-8481)

For ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody...

10CVSS7.5AI score0.01855EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•34 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8489)

Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management all published versions enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management...

7.8CVSS7.3AI score0.0034EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•29 views

ABB Multiple System 800xA Products Incorrect Default Permissions (CVE-2020-8487)

Insufficient protection of the inter-process communication functions in ABB System 800xA Base all published versions enables an attacker authenticated on the local system to inject data, affect node redundancy handling. This plugin only works with Tenable.ot. Please visit...

7.8CVSS7.3AI score0.0033EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•34 views

ABB Central Licensing System Improper Access Control (CVE-2020-8471)

For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...

7.8CVSS7.6AI score0.01548EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•33 views

ABB PB610 Panel Builder 600 Use of Hard-Coded Credentials (CVE-2019-7225)

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool Panel Builder 600 to flash a new interface and Tags MODBUS coils mapping to the HMI. These credentials are the idal123...

8.8CVSS7.8AI score0.02895EPSS
SaveExploits1References5
Tenable Nessus
Tenable Nessus
•added 2023/03/29 12:00 a.m.•34 views

ABB 800xA Improper Input Validation (CVE-2021-22277)

Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service. This plugin only works with Tenable.ot. Please visit...

7.8CVSS7.4AI score0.00947EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2023/03/28 12:00 a.m.•13 views

PT-2023-2287 · Abb · Abb Ac500

Name of the Vulnerable Software and Affected Versions: ABB AC500 V2 versions 2.0.0 through 2.8.5 Description: The issue is related to insufficient exception state checking in the ABB AC500 programmable logic controller's software, which can be exploited by a remote attacker to cause a denial of...

5.3CVSS5.2AI score0.00557EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2023/03/28 12:00 a.m.•12 views

SDM600 安全漏洞

ABB SDM600 is a system data manager from ABB Switzerland. A security vulnerability exists in SDM600 versions prior to 1.2.23000.291, which stems from the presence of a service authorization validation vulnerability that can be exploited by an attacker to access sensitive data by reading directly...

7.7CVSS7.3AI score0.00484EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2023/03/28 12:00 a.m.•14 views

The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 lies in improper initialization of resources, which allows attackers to trigger maintenance-related failures.

The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 is related to improper initialization of resources. Exploiting this...

6.2CVSS5.9AI score0.00171EPSS
SaveExploits0References2Affected Software13
NVD
NVD
•added 2023/03/27 5:15 a.m.•29 views

CVE-2022-4126

Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207...

9.8CVSS9.6AI score0.00621EPSS
SaveExploits0References1
Rows per page