Lucene search
+L

29070 matches found

Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.24 views

Siemens LOGO! 8 BM Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-25232)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port...

7.5CVSS7.4AI score0.00667EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.16 views

Siemens LOGO! Insufficient Verification of Data Authenticity (CVE-2022-36360)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker t...

7.5CVSS7.1AI score0.00277EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.16 views

Siemens LOGO! Insufficiently Protected Credentials (CVE-2017-12734)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V1.81.2. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use...

7.5CVSS7AI score0.01449EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.15 views

Siemens LOGO! Web Server Buffer Copy Without Checking Size of Input (CVE-2020-7593)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants V1.81.01 - V1.81.03, LOGO! 8 BM incl. SIPLUS variants V1.82.01, LOGO! 8 BM incl. SIPLUS variants V1.82.02. A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacke...

9.8CVSS8.5AI score0.09071EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.19 views

Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25234)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions UDF in a password protected way. This...

7.7CVSS7.5AI score0.00304EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.55 views

Oracle Linux 8 : virt:ol / and / virt-devel:rhel (ELSA-2023-5264)

The remote Oracle Linux 8 host has packages installed that are affected by multiple vulnerabilities as referenced in the ELSA-2023-5264 advisory. - Fixes: CVE-2022-40284 - CVE-2023-3354 QEMU: VNC: improper I/O watch removal in TLS handshake can lead to remote unauthenticated denial of service...

7.8CVSS6.5AI score0.01606EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.18 views

Siemens LOGO! 8 BM Improper Handling of Exceptional Conditions (CVE-2020-25236)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The control logic CL the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the...

5.5CVSS5.7AI score0.00266EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.24 views

Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25233)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. This plugin only works with Tenable.ot. Please visit...

5.5CVSS6.5AI score0.00191EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.26 views

Siemens LOGO! 8 BM Devices Buffer Copy Without Checking Size of Input (CVE-2022-36361)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. Th...

9.8CVSS8.2AI score0.00979EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.19 views

Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25229)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any...

7.5CVSS7.5AI score0.00642EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.27 views

Siemens LOGO! 8 BM Missing Authentication For Critical Function (CVE-2019-10919)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerabili...

9.4CVSS7.1AI score0.02746EPSS
SaveExploits3References7
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.20 views

Siemens LOGO! 8 BM Devices Improper Input Validation (CVE-2022-36362)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be...

7.5CVSS7.2AI score0.00942EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.23 views

Siemens LOGO! 8 BM Devices Improper Validation of Specified Index, Position, or Offset in Input (CVE-2022-36363)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory. This plugin only...

5.3CVSS5.6AI score0.00428EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.15 views

Siemens LOGO! 8 BM Plaintext Storage of a Password (CVE-2019-10921)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...

7.5CVSS7.3AI score0.02447EPSS
SaveExploits3References7
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.22 views

Siemens LOGO! Channel Accessible By Non-Endpoint (CVE-2017-12735)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. An attacker who performs a Man-in- the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. This plugin only works with Tenable.ot. Please visit...

7.4CVSS7AI score0.01126EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.19 views

Siemens LOGO! 8 BM Insufficiently Protected Credentials (CVE-2020-25235)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins. This plugin on...

7.5CVSS7.4AI score0.01161EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.21 views

Siemens LOGO! Missing Authentication For Critical Function (CVE-2020-7589)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...

9.1CVSS7.8AI score0.0199EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.21 views

Siemens LOGO! 8 BM Improper Handling of Extra Values (CVE-2019-10920)

A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...

7.5CVSS7.4AI score0.01504EPSS
SaveExploits2References7
Tenable Nessus
Tenable Nessus
added 2023/09/21 12:00 a.m.59 views

Oracle Linux 8 : mariadb:10.3 (ELSA-2023-5259)

The remote Oracle Linux 8 host has packages installed that are affected by multiple vulnerabilities as referenced in the ELSA-2023-5259 advisory. galera 25.3.37-1 - Rebase to 25.3.37 Judy 1.0.5-18.0.1 - Rebuild Orabug: 31667911 mariadb 3:10.3.39-1 - MariaDB 10.3.32 socat: E Failed to set SNI host...

7.5CVSS7.2AI score0.51733EPSS
SaveExploits3References5
NVD
NVD
added 2023/09/20 4:15 p.m.31 views

CVE-2023-5074

Use of a static key to protect a JWT token used in user authentication can allow an for an authentication bypass in D-Link D-View 8 v2.0.1.28...

9.8CVSS9.7AI score0.67914EPSS
SaveExploits1References1
Rows per page