319198 matches found
CVE-2025-3117
CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists impacting configuration file paths that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser...
CVE-2025-3117
CVE-2025-3117 affects Schneider Electric Modicon Controllers (M241/M251/M258/LMC058/M262). The vulnerability is a Cross-Site Scripting (CWE-79) caused by improper neutralization of input during web page generation, allowing an authenticated malicious user to inject unvalidated data that could mod...
CVE-2025-3117
CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists impacting configuration file paths that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser...
CVE-2025-3905
CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser...
CVE-2025-3899
CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser...
CVE-2025-5742
CWE-79: Improper Neutralization of Input During Web Page Generation ‘Cross-site Scripting’ vulnerability exists when an authenticated user modifies configuration parameters on the web server...
Advisory ROSA-SA-2025-2867
Software: freetype 2.8 OS: rosa-server79 packageevrstring: freetype-2.8-14.0.1.res7.1 CVE-ID: CVE-2025-27363 BDU-ID: 2025-02719 CVE-Crit: HIGH CVE-DESC.: A vulnerability in the FreeType font rasterization library is related to reading beyond buffer boundaries in memory. Exploitation of the...
CVE-2024-8401
CWE-79: Improper Neutralization of Input During Web Page Generation ‘Cross-site Scripting’ vulnerability exists when an authenticated attacker modifies folder names within the context of the product...
CVE-2023-5987
A CWE-79 Improper Neutralization of Input During Web Page Generation Cross-site Scripting vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected...
CVE-2022-22812
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk V2.6.2...
CVE-2020-7570
A CWE-79 Improper Neutralization of Input During Web Page Generation Cross-site Scripting Stored vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect...
CVE-2020-7571
A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation Cross-site Scripting Reflected vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of use...
CVE-2020-28210
A CWE-79 Improper Neutralization of Input During Web Page Generation Cross-site Scripting vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser...
CVE-2018-1000870
PHPipam version 1.3.2 and earlier contains a CWE-79 vulnerability in /app/admin/users/print-user.php that can result in Execute code in the victims browser. This attack appear to be exploitable via Attacker change theme parameter in user settings. AdminVictim views user in admin-panel and gets...
CVE-2019-6853
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702 , which could enable a successful Cross-site Scripting XSS attack when using the products web server...
CVE-2019-10059
The legacy finger service TCP port 79 is enabled by default on various older Lexmark devices...
Mars: [XSS] Reflected XSS via POST request in (███████)
A reflected Cross-Site Scripting XSS vulnerability was identified in the celular parameter of a POST request to the homepage of a Mars-owned website. The vulnerability was classified as medium severity with a CVSS score of 6.2. The application failed to properly sanitize user input before renderi...
CVE-2025-30315 Adobe Connect | Cross-site Scripting (Stored XSS) (CWE-79)
Adobe Connect versions 12.8 and earlier are affected by a stored Cross-Site Scripting XSS vulnerability that could be abused by an attacker to inject malicious scripts into vulnerable form fields. Malicious JavaScript may be executed in a victim’s browser when they browse to the page containing t...
CVE-2025-30315
Summary: Adobe Connect versions ≤ 12.8 are vulnerable to a stored XSS in vulnerable form fields, allowing injected JavaScript to run in a victim’s browser when visiting the affected page. Impact (as stated): stored XSS with potential for script execution in the user context. Affected components: ...
CVE-2025-30314
CVE-2025-30314 (Adobe Connect) affects Adobe Connect versions 12.8 and earlier due to a stored Cross-Site Scripting (XSS) vulnerability in vulnerable form fields. The underlying issue allows an attacker to inject malicious scripts, which may execute in a victim’s browser when they load the page c...