95 matches found
CVE-2025-3424
The IntelliSpace portal application utilizes .NET Remoting for its functionality. The vulnerability arises from the exploitation of port 755 through the "Object Marshalling" technique, which allows an attacker to read internal files without any authentication. This is possible by crafting specifi...
CVE-2025-3425
The CVE-2025-3425 issue affects Philips IntelliSpace Portal (12 and earlier). It arises from a .NET Remoting deserialization vulnerability exposed via port 755, where TypeFilterLevel was configured to Full, potentially enabling remote code execution. Impact is described as remote code execution w...
CVE-2025-3424
The CVE-2025-3424 issue affects Philips IntelliSpace Portal (versions 12 and prior) and stems from the .NET Remoting-based access on port 755 via Object Marshalling, enabling an unauthenticated attacker to read internal files by crafting specific Remoting URLs derived from client-side configurati...
PT-2025-15255 · Philips · Intellispace Portal
Name of the Vulnerable Software and Affected Versions: IntelliSpace Portal versions 12 and prior Description: The issue arises from the exploitation of port 755 through the "Object Marshalling" technique, allowing an attacker to read internal files without authentication. This is possible by...
PT-2025-15269 · Philips · Intellispace Portal
Name of the Vulnerable Software and Affected Versions: IntelliSpace Portal versions 12 and prior Description: The issue arises from the exploitation of port 755 through a deserialization vulnerability in the IntelliSpace portal application, which utilizes .NET Remoting for its functionality. The...
Philips IntelliSpace Portal 路径遍历漏洞
Philips IntelliSpace Portal is an advanced medical image analysis platform from Philips Netherlands that provides multimodal image processing and automated diagnostic tools. A path traversal vulnerability exists in Philips IntelliSpace Portal version 12 and earlier, which stems from the...
CISA Releases Two Industrial Control Systems Advisories
CISA released two Industrial Control Systems ICS advisories on February 25, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-056-01 Rockwell Automation PowerFlex 755 ICSMA-25-030-01 Contec Health CMS8000 Patien...
CVE-2025-0631 PowerFlex® 755 Credential Exposure Vulnerability
A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text...
CVE-2025-0631 PowerFlex® 755 Credential Exposure Vulnerability
A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text...
PT-2025-3990 · Rockwell Automation · Powerflex 755
Name of the Vulnerable Software and Affected Versions: Rockwell Automation PowerFlex 755 affected versions not specified Oracle WebLogic Server affected versions not specified Description: A credential exposure vulnerability exists due to the use of HTTP, resulting in credentials being sent in...
Rockwell Automation PowerFlex 755 安全漏洞
The Rockwell Automation PowerFlex 755 is an AC inverter from Rockwell Automation. A security vulnerability exists in the Rockwell Automation PowerFlex 755 that originates from sending credentials in clear text...
CVE-2023-49584
SAP Fiori launchpad - versions SAPUI 750, SAPUI 754, SAPUI 755, SAPUI 756, SAPUI 757, SAPUI 758, UI700 200, SAPBASIS 793, allows an attacker to use HTTP verb POST on read-only service causing low impact on Confidentiality of the application...
Design/Logic Flaw
SAP Fiori launchpad - versions SAPUI 750, SAPUI 754, SAPUI 755, SAPUI 756, SAPUI 757, SAPUI 758, UI700 200, SAPBASIS 793, allows an attacker to use HTTP verb POST on read-only service causing low impact on Confidentiality of the application...
CVE-2023-49580
SAP GUI for Windows and SAP GUI for Java — affected: SAP_BASIS 755, 756, 757, 758. Unauthenticated attacker can access restricted/confidential information and can create Layout configurations in the ABAP List Viewer, causing mild impacts to integrity and availability (e.g., increased ABAP respons...
755.ru Cross Site Scripting vulnerability OBB-3680488
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CVE-2023-33991 Stored Cross-Site Scripting (Stored XSS) vulnerability in SAP UI5 Variant Management
SAP UI5 Variant Management - versions SAPUI 750, SAPUI 754, SAPUI 755, SAPUI 756, SAPUI 757, UI700 200, does not sufficiently encode user-controlled inputs on reading data from the server, resulting in Stored Cross-Site Scripting Stored XSS vulnerability. After successful exploitation, an attacke...
SAP Variant Management 跨站脚本漏洞
SAP Variant Management is a platform from SAP, Germany, for storing user-created settings for Smart Filter Fields and settings created for Smart Forms. A cross-site scripting vulnerability exists in SAP Variant Management that stems from the presence of a stored cross-site scripting XSS...
CVE-2023-30743
Due to improper neutralization of input in SAPUI5 - versions SAPUI 750, SAPUI 754, SAPUI 755, SAPUI 756, SAPUI 757, UI700 200, sap.m.FormattedText SAPUI5 control allows injection of untrusted CSS. This blocks user’s interaction with the application. Further, in the absence of URL validation by th...
CVE-2023-29111
The SAP AIF ODATA service - versions 755, 756, discloses more detailed information than is required. An authorized attacker can use the collected information possibly to exploit the component. As a result, an attacker can cause a low impact on the confidentiality of the application...
Design/Logic Flaw
The SAP AIF ODATA service - versions 755, 756, discloses more detailed information than is required. An authorized attacker can use the collected information possibly to exploit the component. As a result, an attacker can cause a low impact on the confidentiality of the application...